Microsleep events (MSE) are short intrusions of sleep under the demand of sustained attention. They can impose a major threat to safety while driving a car and are considered one of the most significant causes of traffic accidents. Driver’s fatigue and MSE account for up to 20% of all car crashes in Europe and at least 100,000 accidents in the US every year. Unfortunately, there is not a standardized test developed to quantify the degree of vigilance of a driver. To account for this problem, different approaches based on biosignal analysis have been studied in the past. In this paper, we investigate an electrocardiographic-based detection of MSE using morphological and rhythmical features. 14 records from a car driving simulation study with a high incidence of MSE were analyzed and the behavior of the ECG features before and after an MSE in relation to reference baseline values (without drowsiness) were investigated. The results show that MSE cannot be detected (or predicted) using only the ECG. However, in the presence of MSE, the rhythmical and morphological features were observed to be significantly different than the ones calculated for the reference signal without sleepiness. In particular, when MSE were present, the heart rate diminished while the heart rate variability increased. Time distances between P wave and R peak, and R peak and T wave and their dispersion increased also. This demonstrates a noticeable change of the autonomous regulation of the heart. In future, the ECG parameter could be used as a surrogate measure of fatigue.

1 Introduction

Microsleep events (MSE) are short periods of sleep that can last from a fraction of a second to several seconds and can become extremely dangerous while driving a car. They are one of the most common causes of traffic accidents. In Europe, recent studies have shown that up to 20% of all crashes on the road are related to driver’s fatigue, while in the US more than 100,000 automobile crashes annually are driven by MSE. Furthermore, in the transport industry, diminished vigilance is the main cause of truck crashes and around 60% of all fatal causalities. Thus, the prevention of such accidents has become a relevant problem to society [1].

Since fatigue and drowsiness have a severe impact on the driver’s level of concentration, reaction time, memory and driving performance, it has been observed that physiological parameters are modified when sleepiness appears. However, in contrast to the well-known alcoholic tests, there is no equivalent, forensically valid test for sleepiness. For this reason, other approaches based on biosignal analysis are being used to quantify the degree of vigilance of a driver. The main goal is to alert the driver when he is not sufficiently aware of the situation and thus prevent an accident [2].

In this paper, we hypothesize that an electrocardiogram- (ECG) based analysis can be developed to detect an MSE. For this purpose, we developed a large variety of rhythmical and morphological features and investigated the behavior of those before and after an MSE in relation to reference baseline values without sleepiness. We evaluated the discriminating power of the ECG-based descriptors using recordings from a car driving simulation study.

2 Materials

14 young and healthy subjects participated in the car driving simulation study, for which a laboratory with a real car, a large projection wall and a control room next to it was conceived as shown in Figure 1. For the experiment, the subjects had to arrive at the lab before 1:00 AM after a normal day of activity and a minimum of 16 h of continuous wakefulness. The experiment consisted of 7 driving sessions of 40 min, each followed by the responding of a questionnaire to assess sleepiness with a duration of 15 min and a short pause of 5 min before the next driving session began. By 8:00 AM the experiment should have ended. The road chosen for driving was a two-lane street with little curves and a non-varying landscape. The environment was intentionally designed to be monotonous to reduce vigilance, increase sleepiness and stimulate MSE. The manual annotation of MSE and its duration was carried out by two independent experts using three video streams acquired from the driving scene and subject [3]. No ethical approval was needed for this study.

Figure 1 Laboratory used for MSE study. (A) Car driving simulation environment. (B) Control room for subject monitoring.
Figure 1

Laboratory used for MSE study. (A) Car driving simulation environment. (B) Control room for subject monitoring.

A total of 15 different signals were recorded during the experiment including driving performance and biosignals such as pupil size based on an eye-tracking-system, electroencephalograms (EEG), electrooculograms (EOG), electromyograms (EMG) and the ECG. The latter was recorded at a sampling rate of 256 Hz using Einthoven lead II which is characterized by a large monophasic QRS complex and positive concordant P and T waves.

3 Methods

3.1 Signal preprocessing

For the purpose of reducing the impact of noise and other artifacts that can corrupt the morphological features, a prefiltering step is necessary. A phase free Butterworth high pass filter of order 6 with a cutoff frequency at 0.5 Hz was used to remove baseline wander. High frequency, muscle noise and power line hum were canceled using an equivalent low pass Butterworth filter with the cutoff frequency of 40 Hz [4].

3.2 ECG wave detection

The algorithm beginns with the detection of the QRS complexes. The method uses the stationary wavelet transform (SWT) to potentiate the spectral components of the signal located below 50 Hz what coincides with the spectral components of the QRS complex. An adaptive threshold is then applied and signal portions above threshold are labeled as QRS complexes. The T wave detection is the second step. Here, a PQRS cancellation is first carried out and an SWT is performed on the resulting signal. Again, signal portions located after the QRS complex that are above threshold are detected as the T wave. Having the QRS complex and the T wave, the ST segment can also be automatically annotated. Finally, the P wave is found in a similar manner as the T wave, but a cancellation of the QRST segment is performed before a new SWT of the resulting signal is computed.

3.3 Feature extraction

From an ECG signal a large variety of features can be obtained. Two main categories are distinguished, rhythmical and morphological. The rhythmnical features reflect the heart rate varibility (HRV) and are closely linked to the autonomous regulation of the heart. On the other side, the morphological features of the ECG waves capture the depolarization repolarization process in the heart and reflect the cardiac electrophysiology. In this work, we extracted features from both categories.

A segment of the ECG signal before and after the MSE was extracted from the ECG. Two type of analyses were carried out. In the first one, the length of the segment was chosen to be 120 s. In the second approach, the chosen segment was 30 s long. The change in temporal resolution was intended to investigate if there is a tendency to short-term or to long-term effects around the MSE.

Since no MSE were present in any of the subjects during the first 20 min of the very first driving session, we used that interval as reference. We utilized segments of the same length as the ones being analyzed to calculate the ECG features used as reference. We assume that the feature values obtained from those first 20 min are comparable to ECG descriptors during full vigilance. Finally, if two or more MSE were present within the same analysis interval, they were all removed from the study.

3.3.1 Rhythmical features

The series of RR intervals obtained from the ECG is used for the development of rhythmical descriptors. The feature extraction from this time series is primarily based on the analysis of heart rate varibility (HRV) [5]. Figures 2B and 2C display the RR time series and the meaning of HRV.

Figure 2 Signal processing work flow for feature extraction. (A) Manually annotated MSE and its analysis interval of 30 s. (B) Automatic detection of ECG waves and wave intervals. (C) Extracted RR time series and its rhythmical properties. (D) Segmented QRS complex and its morphological features.
Figure 2

Signal processing work flow for feature extraction. (A) Manually annotated MSE and its analysis interval of 30 s. (B) Automatic detection of ECG waves and wave intervals. (C) Extracted RR time series and its rhythmical properties. (D) Segmented QRS complex and its morphological features.

From the time domain, standard descriptors such as the mean RR, SDNN, rMSSD, PNN50 together with other geometrical and non-linear parameters were calculated.

For the frequency domain, a special consideration was taken for the RR time series because they were extracted from an ECG segment of the length 30 s or 120 s. In this case, the Welch’s method cannot be successfully applied. For this reason, a periodic extension of the RR time series to a length of 5 min was performed followed by an interpolation to equally spaced RR intervals with a sampling rate of 4 Hz. The power spectral density (PSD) of the resulting series is then computed using the Welch method with a Hann window of 256 sample points, an overlap of 50% and a zero padding to 1024 sample points. From the PSD, standard features such as LF, HF, and LF/HF ratio were calculated.

The time-frequency domain was also used to generate features. For this purpose, the wavelet packet analysis (WPA) was carried out with the Daubechies Symlet 12, which delivers a good compromise between time and frequency resolution and its almost symmetrical shape reduces distortions in the transformed signal. For the WPA, an interpolation to a sampling rate of 2.4 Hz was chosen. This allows a frequency resolution of 0.0375 Hz and a time resolution of 13.33 s at decomposition level 5. From this transformed signal, similar features as the ones obtained from the time and frequency domain HRV analysis were also computed here.

A total of 242 features were obtained from the rhythmical properties of the ECG.

3.3.2 Morphological features

For the extraction of morphological features, every ECG wave is segmented in the signal. So for example, the QRS complex is extracted by placing an interval of 100 ms before and after the R peak. Analogously, the P wave, the ST segment and the T wave are also segmented considering their respective durations. Typically used wave descriptors such as amplitude, width, symmetry, curvature, peakness, slope, center of mass and energy were computed from all EGG waves. Time distances between the waves such as the PR or RT intervals and their dispersion (standard deviation of the intervals) were also calculated [2]. The corrected RT interval according to Bazett was also used as feature. Figures 2B and 2D briefly show how the PR and RT intervals together with the other morphological features are obtained.

In order to achieve morphological features that were comparable among different subjects and take into account the variability of the wave morphology within the same subject, we carried out a normalization of the morphological features. For this purpose, an ECG template was created from the beats of highest signal quality in the reference phase of the signal. Every morphological feature obtained from any part of the signal was subtracted from the corresponding feature value of the template. Then, the mean and standard deviation features computed from the beats used to create the template were used for normalization.

A total of 104 features were obtained from the morphological properties of the ECG.

3.4 Statistical analysis

For the purpose of comparing features coming from the reference interval, and the segments before and after the MSE, a Wilcoxon signed-rank test was performed. The statistical significance was assumed for an error probability (p-value) of p < 0.05.

A summary of the signal processing work flow developed for this work can be seen in Figure 2.

4 Results

We present a summary of the features that turned out to be most significant (lowest p value) for this study.

4.1 Rhythmical features

From the statistical analysis of the rhythmical descriptors, we observed that non of them had a significant difference in its median value before and after the MSE. However, when the features from the reference signal were compared to values when an MSE occurred, significant variations were present. In general, the mean heart rate decreased, while the HRV increased. For example, in the analysis of segments of 120 s, the parameter mean RR went from 788 ms (76 bpm) in the reference interval to approximately 880 ms (68 bpm) when MSE were present. A similar behavior was observed for other HRV parameters like rMSSD and pNN50 and for the signal length 30 s. Figure 3 summarizes the most significant results for the rhythmical features in the form of box plots.

Figure 3 Results of the statistical analysis of rhythmical descriptors. (A) Analysis interval of 120 s. (B) Analysis interval of 30 s.
Figure 3

Results of the statistical analysis of rhythmical descriptors. (A) Analysis interval of 120 s. (B) Analysis interval of 30 s.

4.2 Morphological features

We observed also that non of the morphological features had a significant difference before and after the MSE. As a matter of fact, the comparison between feature values from the reference signal and the MSE showed that the most significant morphological descriptors were also related to rhythmical properties. Among those descriptors, we observed an increase of the median values of the PR and RT corrected intervals and their dispersion. Figure 4 summarizes the most significant results for the morphological features.

Figure 4 Results of the statistical analysis of morphological descriptors. (A) Analysis interval of 120 s. (B) Analysis interval of 30 s.
Figure 4

Results of the statistical analysis of morphological descriptors. (A) Analysis interval of 120 s. (B) Analysis interval of 30 s.

5 Discussion

The statistical analysis showed that no feature had a significant change before and after an MSE. This demonstrates that, at least for this study, the ECG alone is not sufficient for the detection (or prediction) of MSE. This seems to be conform with other studies that demonstrate that MSE are primary observable in the EEG [6]. However, when compared to the reference baseline values from the beginning of the experiment, we did observe that the heart rate goes down, while HRV and PR and RT segments between and their dispersion increase in the presence of MSE. This could be explained by a stronger parasympathetic activity on the cardiovascular regulation what is in accordance with what is known of HRV during no rapid eye movement stages of sleep [7].

6 Conclusion and outlook

The ECG alone is not sufficient for the detection of MSE, since no changes are observed in the short intervals before and after it. However, when compared to the reference baseline values, the ECG features do change significantly in the presence of MSE. This allows the possibility of using ECG descriptors for the quantification of sleepiness and monitoring of vigilance. For this purpose, a direct regression of ECG features to relate them to the level of drowsiness should be carried out. This would also facilitate the risk assessment of an MSE occurring.

Author’s Statement

Research funding: The author state no funding involved. Conflict of interest: Authors state no conflict of interest. Material and methods: Informed consent: Informed consent has been obtained from all individuals included in this study. Ethical approval: The research related to human use complies with all the relevant national regulations, institutional policies and was performed in accordance with the tenets of the Helsinki Declaration, and has been approved by the authors’ institutional review board or equivalent committee.

References

[1] Bergasa LM, Nuevo J, Sotelo MA, Barea R, Lopez ME. Real-time system for monitoring driver vigilance. IEEE Transactions on Intelligent Transportation Systems 2006;7:63–77.10.1109/TITS.2006.869598Search in Google Scholar

[2] Wilhelm B, Stephan E, Dittmann V. Tagesschlaefrigkeit - Gefahren und Konsequenzen fuer den Strassenverkehr. 6. gemeinsames Symposium der DGVM und DGVP am 1.-2. Oktober 2010 in Tuebingen. Schriftenreihe Fahreignung; 2011.Search in Google Scholar

[3] Golz M, Sommer D, Chen, M, Trutschel U, Mandic D. Feature fusion for the detection of microsleep events. J VLSI Sig Proc Syst Signal Image Video Technol. 2007;49:329–42.10.1007/s11265-007-0083-4Search in Google Scholar

[4] Lenis G, Pilia NA, Oesterlein T, Luik A, Schmitt C, Dössel O. P wave detection and delineation in the ECG based on the phase free stationary wavelet transform and using intracardiac atrial electrograms as reference. Biomed Eng/Biomedizinische Technik 2015;61:37–56.10.1515/bmt-2014-0161Search in Google Scholar PubMed

[5] Malik M, Bigger JT, Camm AJ, Kleiger RE, Malliani A, Moss AJ, et al. Heart rate variability standards of measurement, physiological interpretation, and clinical use. Eur Heart J. 1996;17:354–81.10.1093/oxfordjournals.eurheartj.a014868Search in Google Scholar

[6] Davidson PR, Jones RD, Peiris MT. EEG-based lapse detection with high temporal resolution. IEEE Trans Biomed Eng. 2007;54:832–9.10.1109/TBME.2007.893452Search in Google Scholar PubMed

[7] Vanoli E, Adamson PB, Pinna GD, Lazzara R, Orr WC. Heart rate variability during specific sleep stages a comparison of healthy subjects with patients after myocardial infarction. Circulation 1995;91:1918–22.10.1161/01.CIR.91.7.1918Search in Google Scholar

Published Online: 2016-9-30
Published in Print: 2016-9-1

©2016 Gustavo Lenis et al., licensee De Gruyter.

This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.

Articles in the same Issue

  1. Synthesis and characterization of PIL/pNIPAAm hybrid hydrogels
  2. Novel blood protein based scaffolds for cardiovascular tissue engineering
  3. Cell adhesion and viability of human endothelial cells on electrospun polymer scaffolds
  4. Effects of heat treatment and welding process on superelastic behaviour and microstructure of micro electron beam welded NiTi
  5. Long-term stable modifications of silicone elastomer for improved hemocompatibility
  6. The effect of thermal treatment on the mechanical properties of PLLA tubular specimens
  7. Biocompatible wear-resistant thick ceramic coating
  8. Protection of active implant electronics with organosilicon open air plasma coating for plastic overmolding
  9. Examination of dielectric strength of thin Parylene C films under various conditions
  10. Open air plasma deposited antimicrobial SiOx/TiOx composite films for biomedical applications
  11. Systemic analysis about residual chloroform in PLLA films
  12. A macrophage model of osseointegration
  13. Towards in silico prognosis using big data
  14. Technical concept and evaluation of a novel shoulder simulator with adaptive muscle force generation and free motion
  15. Usability evaluation of a locomotor therapy device considering different strategies
  16. Hypoxia-on-a-chip
  17. Integration of a semi-automatic in-vitro RFA procedure into an experimental setup
  18. Fabrication of MEMS-based 3D-μECoG-MEAs
  19. High speed digital interfacing for a neural data acquisition system
  20. Bionic forceps for the handling of sensitive tissue
  21. Experimental studies on 3D printing of barium titanate ceramics for medical applications
  22. Patient specific root-analogue dental implants – additive manufacturing and finite element analysis
  23. 3D printing – a key technology for tailored biomedical cell culture lab ware
  24. 3D printing of hydrogels in a temperature controlled environment with high spatial resolution
  25. Biocompatibility of photopolymers for additive manufacturing
  26. Biochemical piezoresistive sensors based on pH- and glucose-sensitive hydrogels for medical applications
  27. Novel wireless measurement system of pressure dedicated to in vivo studies
  28. Portable auricular device for real-time swallow and chew detection
  29. Detection of miRNA using a surface plasmon resonance biosensor and antibody amplification
  30. Simulation and evaluation of stimulation scenarios for targeted vestibular nerve excitation
  31. Deep brain stimulation: increasing efficiency by alternative waveforms
  32. Prediction of immediately occurring microsleep events from brain electric signals
  33. Determining cardiac vagal threshold from short term heart rate complexity
  34. Classification of cardiac excitation patterns during atrial fibrillation
  35. An algorithm to automatically determine the cycle length coverage to identify rotational activity during atrial fibrillation – a simulation study
  36. Deriving respiration from high resolution 12-channel-ECG during cycling exercise
  37. Reducing of gradient induced artifacts on the ECG signal during MRI examinations using Wilcoxon filter
  38. Automatic detection and mapping of double potentials in intracardiac electrograms
  39. Modeling the pelvic region for non-invasive pelvic intraoperative neuromonitoring
  40. Postprocessing algorithm for automated analysis of pelvic intraoperative neuromonitoring signals
  41. Best practice: surgeon driven application in pelvic operations
  42. Vasomotor assessment by camera-based photoplethysmography
  43. Classification of morphologic changes in photoplethysmographic waveforms
  44. Novel computation of pulse transit time from multi-channel PPG signals by wavelet transform
  45. Efficient design of FIR filter based low-pass differentiators for biomedical signal processing
  46. Nonlinear causal influences assessed by mutual compression entropy
  47. Comparative study of methods for solving the correspondence problem in EMD applications
  48. fNIRS for future use in auditory diagnostics
  49. Semi-automated detection of fractional shortening in zebrafish embryo heart videos
  50. Blood pressure measurement on the cheek
  51. Derivation of the respiratory rate from directly and indirectly measured respiratory signals using autocorrelation
  52. Left cardiac atrioventricular delay and inter-ventricular delay in cardiac resynchronization therapy responder and non-responder
  53. An automatic systolic peak detector of blood pressure waveforms using 4th order cumulants
  54. Real-time QRS detection using integrated variance for ECG gated cardiac MRI
  55. Preprocessing of unipolar signals acquired by a novel intracardiac mapping system
  56. In-vitro experiments to characterize ventricular electromechanics
  57. Continuous non-invasive monitoring of blood pressure in the operating room: a cuffless optical technology at the fingertip
  58. Application of microwave sensor technology in cardiovascular disease for plaque detection
  59. Artificial blood circulatory and special Ultrasound Doppler probes for detecting and sizing gaseous embolism
  60. Detection of microsleep events in a car driving simulation study using electrocardiographic features
  61. A method to determine the kink resistance of stents and stent delivery systems according to international standards
  62. Comparison of stented bifurcation and straight vessel 3D-simulation with a prior simulated velocity profile inlet
  63. Transient Euler-Lagrange/DEM simulation of stent thrombosis
  64. Automated control of the laser welding process of heart valve scaffolds
  65. Automation of a test bench for accessing the bendability of electrospun vascular grafts
  66. Influence of storage conditions on the release of growth factors in platelet-rich blood derivatives
  67. Cryopreservation of cells using defined serum-free cryoprotective agents
  68. New bioreactor vessel for tissue engineering of human nasal septal chondrocytes
  69. Determination of the membrane hydraulic permeability of MSCs
  70. Climate retainment in carbon dioxide incubators
  71. Multiple factors influencing OR ventilation system effectiveness
  72. Evaluation of an app-based stress protocol
  73. Medication process in Styrian hospitals
  74. Control tower to surgical theater
  75. Development of a skull phantom for the assessment of implant X-ray visibility
  76. Surgical navigation with QR codes
  77. Investigation of the pressure gradient of embolic protection devices
  78. Computer assistance in femoral derotation osteotomy: a bottom-up approach
  79. Automatic depth scanning system for 3D infrared thermography
  80. A service for monitoring the quality of intraoperative cone beam CT images
  81. Resectoscope with an easy to use twist mechanism for improved handling
  82. In vitro simulation of distribution processes following intramuscular injection
  83. Adjusting inkjet printhead parameters to deposit drugs into micro-sized reservoirs
  84. A flexible standalone system with integrated sensor feedback for multi-pad electrode FES of the hand
  85. Smart control for functional electrical stimulation with optimal pulse intensity
  86. Tactile display on the remaining hand for unilateral hand amputees
  87. Effects of sustained electrical stimulation on spasticity assessed by the pendulum test
  88. An improved tracking framework for ultrasound probe localization in image-guided radiosurgery
  89. Improvement of a subviral particle tracker by the use of a LAP-Kalman-algorithm
  90. Learning discriminative classification models for grading anal intraepithelial neoplasia
  91. Regularization of EIT reconstruction based on multi-scales wavelet transforms
  92. Assessing MRI susceptibility artefact through an indicator of image distortion
  93. EyeGuidance – a computer controlled system to guide eye movements
  94. A framework for feedback-based segmentation of 3D image stacks
  95. Doppler optical coherence tomography as a promising tool for detecting fluid in the human middle ear
  96. 3D Local in vivo Environment (LivE) imaging for single cell protein analysis of bone tissue
  97. Inside-Out access strategy using new trans-vascular catheter approach
  98. US/MRI fusion with new optical tracking and marker approach for interventional procedures inside the MRI suite
  99. Impact of different registration methods in MEG source analysis
  100. 3D segmentation of thyroid ultrasound images using active contours
  101. Designing a compact MRI motion phantom
  102. Cerebral cortex classification by conditional random fields applied to intraoperative thermal imaging
  103. Classification of indirect immunofluorescence images using thresholded local binary count features
  104. Analysis of muscle fatigue conditions using time-frequency images and GLCM features
  105. Numerical evaluation of image parameters of ETR-1
  106. Fabrication of a compliant phantom of the human aortic arch for use in Particle Image Velocimetry (PIV) experimentation
  107. Effect of the number of electrodes on the reconstructed lung shape in electrical impedance tomography
  108. Hardware dependencies of GPU-accelerated beamformer performances for microwave breast cancer detection
  109. Computer assisted assessment of progressing osteoradionecrosis of the jaw for clinical diagnosis and treatment
  110. Evaluation of reconstruction parameters of electrical impedance tomography on aorta detection during saline bolus injection
  111. Evaluation of open-source software for the lung segmentation
  112. Automatic determination of lung features of CF patients in CT scans
  113. Image analysis of self-organized multicellular patterns
  114. Effect of key parameters on synthesis of superparamagnetic nanoparticles (SPIONs)
  115. Radiopacity assessment of neurovascular implants
  116. Development of a desiccant based dielectric for monitoring humidity conditions in miniaturized hermetic implantable packages
  117. Development of an artifact-free aneurysm clip
  118. Enhancing the regeneration of bone defects by alkalizing the peri-implant zone – an in vitro approach
  119. Rapid prototyping of replica knee implants for in vitro testing
  120. Protecting ultra- and hyperhydrophilic implant surfaces in dry state from loss of wettability
  121. Advanced wettability analysis of implant surfaces
  122. Patient-specific hip prostheses designed by surgeons
  123. Plasma treatment on novel carbon fiber reinforced PEEK cages to enhance bioactivity
  124. Wear of a total intervertebral disc prosthesis
  125. Digital health and digital biomarkers – enabling value chains on health data
  126. Usability in the lifecycle of medical software development
  127. Influence of different test gases in a non-destructive 100% quality control system for medical devices
  128. Device development guided by user satisfaction survey on auricular vagus nerve stimulation
  129. Empirical assessment of the time course of innovation in biomedical engineering: first results of a comparative approach
  130. Effect of left atrial hypertrophy on P-wave morphology in a computational model
  131. Simulation of intracardiac electrograms around acute ablation lesions
  132. Parametrization of activation based cardiac electrophysiology models using bidomain model simulations
  133. Assessment of nasal resistance using computational fluid dynamics
  134. Resistance in a non-linear autoregressive model of pulmonary mechanics
  135. Inspiratory and expiratory elastance in a non-linear autoregressive model of pulmonary mechanics
  136. Determination of regional lung function in cystic fibrosis using electrical impedance tomography
  137. Development of parietal bone surrogates for parietal graft lift training
  138. Numerical simulation of mechanically stimulated bone remodelling
  139. Conversion of engineering stresses to Cauchy stresses in tensile and compression tests of thermoplastic polymers
  140. Numerical examinations of simplified spondylodesis models concerning energy absorption in magnetic resonance imaging
  141. Principle study on the signal connection at transabdominal fetal pulse oximetry
  142. Influence of Siluron® insertion on model drug distribution in the simulated vitreous body
  143. Evaluating different approaches to identify a three parameter gas exchange model
  144. Effects of fibrosis on the extracellular potential based on 3D reconstructions from histological sections of heart tissue
  145. From imaging to hemodynamics – how reconstruction kernels influence the blood flow predictions in intracranial aneurysms
  146. Flow optimised design of a novel point-of-care diagnostic device for the detection of disease specific biomarkers
  147. Improved FPGA controlled artificial vascular system for plethysmographic measurements
  148. Minimally spaced electrode positions for multi-functional chest sensors: ECG and respiratory signal estimation
  149. Automated detection of alveolar arches for nasoalveolar molding in cleft lip and palate treatment
  150. Control scheme selection in human-machine- interfaces by analysis of activity signals
  151. Event-based sampling for reducing communication load in realtime human motion analysis by wireless inertial sensor networks
  152. Automatic pairing of inertial sensors to lower limb segments – a plug-and-play approach
  153. Contactless respiratory monitoring system for magnetic resonance imaging applications using a laser range sensor
  154. Interactive monitoring system for visual respiratory biofeedback
  155. Development of a low-cost senor based aid for visually impaired people
  156. Patient assistive system for the shoulder joint
  157. A passive beating heart setup for interventional cardiology training
Downloaded on 21.4.2026 from https://www.degruyterbrill.com/document/doi/10.1515/cdbme-2016-0063/html
Scroll to top button