Home Best practice: surgeon driven application in pelvic operations
Article Open Access

Best practice: surgeon driven application in pelvic operations

From Neurophysiological Scientific Research towards Applied Technology
  • Thilo B. Krueger EMAIL logo , Celine Wegner , Karin H. Somerlik-Fuchs , Klaus-Peter Hoffmann and Rudi Mattmueller
Published/Copyright: September 30, 2016

Abstract

In applied biomedical engineering and medical industry the transfer of established technology towards customers’ needs is essential for successful development and therefore business opportunities. In chronological order, we can show the transfer of scientific results of neurophysiological research into an existing neuromonitoring system and product which can be used by non-experts in medical technology in the operating room environment. All neurophysiology functions were realized in an intuitive graphical user interface. To stimulate the autonomous nerves, a specialized parameter paradigm was used, different from motor nerve stimulation. In the background, a complex signal processing algorithm recorded smooth muscle and bladder manometry data in synchronized time and automatically detected neurophysiological signals. The acquired data was then presented in real-time. With this effort a complex scientific task could be simplified to a Yes/No statement to the end-user. Beside all the reduction of complexity, the scientific challenge was still obtained, as raw-data is still possible to be recorded.

1 Introduction

Intraoperative Neurophysiological Neuromonitoring (IONM) is a tool for surgeons, neurologists and neurophysiologists to map and continuously supervise nerve functions during surgical interventions. To perform this procedure, a technical device is placed in the operation room (OR) and is operated by trained staff.

IONM during the standard procedure of many surgical interventions is well established; e.g. in neurosurgical, spine or orthopaedic surgeries, the central nervous system, either the brain or the spine, can be endangered. Therefore, IONM is used and established as a standard method with complex setups. In general surgery and ear-nose-and-throat surgery, monitoring is also a fact – standard setups to monitor specific nerves are well established [1].

However, for the pelvic region, a monitoring method for the autonomous nerves was lacking for a long time. One of the challenges lied within finding the possibilities of recording the responses of the autonomous nervous system which could be monitored to perform IONM in the pelvic region. But the need for a method was clearly required due to the postoperative urogenital and anorectal functional disorders. They are accounted to the special complications after surgeries in the pelvic region [2].

A nerve-preserving operation technique could lead to an increased postoperative quality of life. To achieve this goal, a suitable method for identification and sparing of the nerves at risk had to be developed. Many paradigms were comparable to existing IONM methods but needed adjustment in their details. As a result, in recent years, neuromonitoring in the pelvic region, especially during total mesorectal excision (TME) was introduced in Germany as a new monitoring method [3] and was well received. This is now known as pelvic intraoperative (neurophysiologic) neuromonitoring pIONM® or short pIOM®.

We describe the adaptions towards today’s needs from the initial development in the following chapters.

2 Surgeon’s requirements

One major requirement in the OR is the clear representation of recorded data from the device. Regardless of the data complexity, the representation has to be simple and intuitive. In the past the classic visualization of electrophysiological signals was done by displaying the signal amplitudes over time. This needed minimum expertise in curve interpretation of evoked potentials. This display method proved feasible because the signals could be interpreted directly. In contrast, the positive reactions of autonomous nervous stimulation are harder to interpret. Refer to Figure 1 for a comparison of striated and smooth muscle reactions to direct nerve stimulation. Therefore, the most important and clear requirement was to get clear feedback of a positive answer. The user interface depicted the results of a complex signal processing routine in the form of visual clues and parallel audio signal feedback (see Figure 2) [4].

Figure 1: Upper curve (A) presents a muscle response signal of vocal cords after indirect stimulation. Lower picture (B) shows the increasing power content of the signal.
Figure 1:

Upper curve (A) presents a muscle response signal of vocal cords after indirect stimulation. Lower picture (B) shows the increasing power content of the signal.

Figure 2: Recorded EMG in the top graph and pressure signals in the bottom; positive signal responses area automatically recognized and a green bar is lit as feedback.
Figure 2:

Recorded EMG in the top graph and pressure signals in the bottom; positive signal responses area automatically recognized and a green bar is lit as feedback.

During the lifetime of the project, several additional requirements arose and led to changes of the developed system. Of course, this input came mainly from the user, most often the surgeon, but not only. In an early phase of the project, it became clear that neurophysiological needs were different than first thought [5]. Figure 3 illustrates examples of the different information stages of pIONM®, especially in the very beginning. The nervous structure of the pelvic region is much more sophisticated than first thought (compare Figures 3 and 4). Although the understanding of the neuro-anatomic features is already comprehensive, many functions of the autonomous nervous system are still not yet fully understood to guarantee a safe medical OR system.

Figure 3: Left, simplified nervous structure in the pelvic region as believed in 2004 and adapted [5], [6] and right, recorded EMG of the detrusor vesicae after stimulation of the N. Hypogastricus which is not shown left.
Figure 3:

Left, simplified nervous structure in the pelvic region as believed in 2004 and adapted [5], [6] and right, recorded EMG of the detrusor vesicae after stimulation of the N. Hypogastricus which is not shown left.

Figure 4: Left: Correct dissection technique according to [7]. Right: Understanding in year 2016 of nervous structure in the pelvic region, white are the nerve structures drawn.
Figure 4:

Left: Correct dissection technique according to [7]. Right: Understanding in year 2016 of nervous structure in the pelvic region, white are the nerve structures drawn.

In addition, technical-wise, the first recorded data-sets were of poor quality compared to those delivered using the contemporary amplifying and filtering possibilities. In parallel to these fundamental changes, the developing and financial requirements were gathered and realized in a standard V-model of requirements engineering and adjusted to the different generations of the devices.

2.1 First generation and approach

As the operation strategy during TME changed and the tissue containing the nearby nerve structures is dissected [7] (see Figure 4) the urgent need for identification of nerves meanwhile TME arose as direct consequence of post-operative patient care. As consequence of this operation strategy, the survival rate of cancer patients increased and the postoperative quality of life came even more into focus.

A needed and easy-to-use method for intraoperative monitoring was investigated with the aim to directly stimulate and identify the autonomous nerves. At first, existing stimulators were used. Afterwards, the ones supplied by medical companies as IONM devices offered the advantage of the integrated recording possibility and of course the CE certification as medical product. However, the usage of pressure sensing was not yet standard in IONM, although crucial for the application in pelvic monitoring. Direct nerve stimulation with bladder manometry and electromyography (EMG) of the sphincter muscles became later the standard.

Stimulation paradigms to elicit autonomous nervous structures are different than for motor or sensory nerves. The stimulation frequency is higher with approximately 30 Hz, also stimulation currents were chosen higher, in the range of 6–15 mA. As stimulation probes are different in design and having bigger surface areas, the current density remained in the same range. In addition, the recording paradigms had to be adjusted. Muscle recording in the frequency range of 50–250 Hz as main frequency content is standard in IONM. Smooth muscles instead have significant frequency peaks and much lower ranges, mainly between 0.1 and 30 Hz. Therefore, the amplifiers of the monitoring system had to be adjusted to perform reliably in this frequency range.

Also pressure sensing was introduced electronically: a pressure transducer was integrated in the monitoring system and approved as a medical product. With this solution, the first used open water column became redundant and handling in the OR much easier and safe, mainly because the open water system turned into a closed system. Although pressure sensing during intraoperative monitoring was new and never used before, the principles of the closed liquid system were well understood by the OR personnel and teaching of staff was focused on the differences of the intraoperative monitoring system instead. This made the introduction as a product feasible. Last but not least, the usability of all new devices and accessories were augmented by an adequate graphical user interface. This was designed according to the needs of the user [8].

2.2 Current devices

pIOM® during open TME is performed nowadays with a neuromonitoring system enabling bipolar electric stimulation of pelvic autonomic nerves under continuous EMG of the internal and external anal sphincter and manometry of the urinary bladder. For electromyography, bipolar needle electrodes are inserted usually under endosonographic guidance. Prior to neurostimulation, the bladder is filled with 200 ml of saline solution and connected to the interface box (see Figure 5). Intermittent neurostimulation was carried out with a bipolar microfork probe repetitively posterolateral, lateral, anterior and at the level of the pelvic floor.

Figure 5: EMG and pressure setup as described [2].
Figure 5:

EMG and pressure setup as described [2].

2.3 Future devices

The pIOM® systems described in this contribution are only the first of their kind. In TME surgery, still not all needs are addressed. One open main topic to be addressed is the continuous monitoring in addition to the intermittent quality control. To achieve this goal, several techniques were tested [9] but their usability in the OR was lacking good performance. Currently, additional techniques will be investigated to provide continuous monitoring, comparable to thyroid monitoring or neurosurgical monitoring methods [1].

The overall system in terms of a recording and stimulation device and user interface is well established and, in its usage, easy to comprehend and apply. But new generations of hardware and software will follow. Graphical user interfaces have changed significantly in the past. Especially consumer electronics had a high impact on the requirements and needs of the user. Touch based devices of consumer electronics are suggesting easier to use systems and wizard-like structures, comparable to Figure 6 and this need has to be transferred to IONM and pIOM§ devices.

Figure 6: Example of Wizard-Like graphical user interface to guide through a procedure. In spine surgery the user can choose the level to monitor (A), is helped to place the electrodes (B), gets clear and interpreted feedback of the stimulation response (C) and is warned if anything is wrong (D).
Figure 6:

Example of Wizard-Like graphical user interface to guide through a procedure. In spine surgery the user can choose the level to monitor (A), is helped to place the electrodes (B), gets clear and interpreted feedback of the stimulation response (C) and is warned if anything is wrong (D).

New developments will also be done for the accessories, even if existing types are very suitable for current operation techniques. So recording electrodes and stimulation probes will be available in new designs and may also provide additional features. As surgical techniques are changing and new surgical tools are introduced, the accessories will be adapted to the new tools and surgical techniques [10].

3 Conclusion

We established a functional system to intraoperatively monitor autonomous nervous signals in the pelvic region. The high quality of the surgical system addresses especially laparoscopic interventions, e.g. TME. As the development of a medical device is a complex task, the approach was based on an already existing system for intraoperative neuromonitoring. Within this scope, we could investigate a new generation platform to perform optimal during surgical interventions. We presented the first technical results, software algorithms, graphical user representation, the approach of stimulation, and recordings in the field of experimental surgery.

Acknowledgement

The authors would like to thank the autoPIN consortium for their support.

Author’s Statement

Research funding: The autoPIN project was funded by the Federal Ministry of Education and Research (BMBF, Grand number 13GW0022C). Conflict of interest: Thilo Krüger, Celine Wegner and KH Somerlik-Fuchs are full-time employees of the research and development department of inomed Medizintechnik GmbH. Material and Methods: Informed consent: Informed consent is not applicable. Ethical approval: The conducted research is not related to either human or animal use.

References

[1] Loftus CM, Biller J, Baron EM. Intraoperative Neuromonitoring. 1st ed. McGraw Hill Education; 2013.Search in Google Scholar

[2] Lange MM, van de Velde CJ. Urinary and sexual dysfunction after rectal cancer treatment. Nat Rev Urol. 2011;8:51–7.10.1038/nrurol.2010.206Search in Google Scholar

[3] Kneist W, Kauff DW, Juhre V, Hoffmann KP, Lang H. Is IONM associated with better functional outcome in patients undergoing open TME? Results of a case-control study. Eur J Surg Onc. 2013;39:994–9.10.1016/j.ejso.2013.06.004Search in Google Scholar

[4] Kauff DW, Koch KP, Somerlik KH, Hoffmann KP, Lang H, Kneist W. Evaluation of two-dimensional intraoperative neuromonitoring for predicting urinary and anorectal function after rectal cancer surgery. Int J Col Dis. 2013;28:659–64.10.1007/s00384-013-1662-4Search in Google Scholar

[5] Krueger T, Kneist W, Junginger Th. Intraoperative Stimulation und Messtechnik an autonomen Beckennerven zur Evaluierung und Optimierung nervenschonender Operationstechniken. Automed Saarbrücken, 2004;49–50, ISBN 3-00-013509-X.Search in Google Scholar

[6] Rijkhoff NJM Wijkstra H, van Kerrebroeck EPV, Bebruyne FMJ. Urinary bladder control by electrical stimulation: review of electrical stimulation techniquees in spinal cord injury. Neur Urodynam. 1997;16:39–53.10.1002/(SICI)1520-6777(1997)16:1<39::AID-NAU6>3.0.CO;2-FSearch in Google Scholar

[7] Bleday R, Garcia-Aquilar J. Surgical treatment of rectal cancer. In: Wolff BG, Fleshman JW, Beck DE, et al, editors. The ASCRS textbook of colon and rectal surgery. New York: Springer Science; 2007. P. 413–36.10.1007/978-0-387-36374-5_30Search in Google Scholar

[8] Kauff DW, Koch KP, Hoffmann KP, Lang H, Kneist W. Minimal invasive pelvic neuromonitoring – technical demands and requirements. Biom Tech. 2013;1:4369–70.10.1515/bmt-2013-4369Search in Google Scholar

[9] Kauff DW, Kempski O, Koch KP, Huppert S, Hoffmann KP, Lang H, et al. Continuous intraoperative monitoring of autonomic nerves during low anterior rectal resection: an innovative approach for observation of functional nerve integrity in pelvic surgery. Lang Arch Surg. 2012;397:787–92.10.1007/s00423-011-0900-xSearch in Google Scholar

[10] Grade M, Beham AW, Schüler P, Kneist W, Ghadimi BM. Pelvic intraoperative neuromonitoring during robotic-assisted low anterior resection for rectal cancer. J Robot Surg. 2016;10:157–60.10.1007/s11701-015-0556-6Search in Google Scholar

Published Online: 2016-9-30
Published in Print: 2016-9-1

©2016 Thilo B. Krueger et al., licensee De Gruyter.

This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.

Articles in the same Issue

  1. Synthesis and characterization of PIL/pNIPAAm hybrid hydrogels
  2. Novel blood protein based scaffolds for cardiovascular tissue engineering
  3. Cell adhesion and viability of human endothelial cells on electrospun polymer scaffolds
  4. Effects of heat treatment and welding process on superelastic behaviour and microstructure of micro electron beam welded NiTi
  5. Long-term stable modifications of silicone elastomer for improved hemocompatibility
  6. The effect of thermal treatment on the mechanical properties of PLLA tubular specimens
  7. Biocompatible wear-resistant thick ceramic coating
  8. Protection of active implant electronics with organosilicon open air plasma coating for plastic overmolding
  9. Examination of dielectric strength of thin Parylene C films under various conditions
  10. Open air plasma deposited antimicrobial SiOx/TiOx composite films for biomedical applications
  11. Systemic analysis about residual chloroform in PLLA films
  12. A macrophage model of osseointegration
  13. Towards in silico prognosis using big data
  14. Technical concept and evaluation of a novel shoulder simulator with adaptive muscle force generation and free motion
  15. Usability evaluation of a locomotor therapy device considering different strategies
  16. Hypoxia-on-a-chip
  17. Integration of a semi-automatic in-vitro RFA procedure into an experimental setup
  18. Fabrication of MEMS-based 3D-μECoG-MEAs
  19. High speed digital interfacing for a neural data acquisition system
  20. Bionic forceps for the handling of sensitive tissue
  21. Experimental studies on 3D printing of barium titanate ceramics for medical applications
  22. Patient specific root-analogue dental implants – additive manufacturing and finite element analysis
  23. 3D printing – a key technology for tailored biomedical cell culture lab ware
  24. 3D printing of hydrogels in a temperature controlled environment with high spatial resolution
  25. Biocompatibility of photopolymers for additive manufacturing
  26. Biochemical piezoresistive sensors based on pH- and glucose-sensitive hydrogels for medical applications
  27. Novel wireless measurement system of pressure dedicated to in vivo studies
  28. Portable auricular device for real-time swallow and chew detection
  29. Detection of miRNA using a surface plasmon resonance biosensor and antibody amplification
  30. Simulation and evaluation of stimulation scenarios for targeted vestibular nerve excitation
  31. Deep brain stimulation: increasing efficiency by alternative waveforms
  32. Prediction of immediately occurring microsleep events from brain electric signals
  33. Determining cardiac vagal threshold from short term heart rate complexity
  34. Classification of cardiac excitation patterns during atrial fibrillation
  35. An algorithm to automatically determine the cycle length coverage to identify rotational activity during atrial fibrillation – a simulation study
  36. Deriving respiration from high resolution 12-channel-ECG during cycling exercise
  37. Reducing of gradient induced artifacts on the ECG signal during MRI examinations using Wilcoxon filter
  38. Automatic detection and mapping of double potentials in intracardiac electrograms
  39. Modeling the pelvic region for non-invasive pelvic intraoperative neuromonitoring
  40. Postprocessing algorithm for automated analysis of pelvic intraoperative neuromonitoring signals
  41. Best practice: surgeon driven application in pelvic operations
  42. Vasomotor assessment by camera-based photoplethysmography
  43. Classification of morphologic changes in photoplethysmographic waveforms
  44. Novel computation of pulse transit time from multi-channel PPG signals by wavelet transform
  45. Efficient design of FIR filter based low-pass differentiators for biomedical signal processing
  46. Nonlinear causal influences assessed by mutual compression entropy
  47. Comparative study of methods for solving the correspondence problem in EMD applications
  48. fNIRS for future use in auditory diagnostics
  49. Semi-automated detection of fractional shortening in zebrafish embryo heart videos
  50. Blood pressure measurement on the cheek
  51. Derivation of the respiratory rate from directly and indirectly measured respiratory signals using autocorrelation
  52. Left cardiac atrioventricular delay and inter-ventricular delay in cardiac resynchronization therapy responder and non-responder
  53. An automatic systolic peak detector of blood pressure waveforms using 4th order cumulants
  54. Real-time QRS detection using integrated variance for ECG gated cardiac MRI
  55. Preprocessing of unipolar signals acquired by a novel intracardiac mapping system
  56. In-vitro experiments to characterize ventricular electromechanics
  57. Continuous non-invasive monitoring of blood pressure in the operating room: a cuffless optical technology at the fingertip
  58. Application of microwave sensor technology in cardiovascular disease for plaque detection
  59. Artificial blood circulatory and special Ultrasound Doppler probes for detecting and sizing gaseous embolism
  60. Detection of microsleep events in a car driving simulation study using electrocardiographic features
  61. A method to determine the kink resistance of stents and stent delivery systems according to international standards
  62. Comparison of stented bifurcation and straight vessel 3D-simulation with a prior simulated velocity profile inlet
  63. Transient Euler-Lagrange/DEM simulation of stent thrombosis
  64. Automated control of the laser welding process of heart valve scaffolds
  65. Automation of a test bench for accessing the bendability of electrospun vascular grafts
  66. Influence of storage conditions on the release of growth factors in platelet-rich blood derivatives
  67. Cryopreservation of cells using defined serum-free cryoprotective agents
  68. New bioreactor vessel for tissue engineering of human nasal septal chondrocytes
  69. Determination of the membrane hydraulic permeability of MSCs
  70. Climate retainment in carbon dioxide incubators
  71. Multiple factors influencing OR ventilation system effectiveness
  72. Evaluation of an app-based stress protocol
  73. Medication process in Styrian hospitals
  74. Control tower to surgical theater
  75. Development of a skull phantom for the assessment of implant X-ray visibility
  76. Surgical navigation with QR codes
  77. Investigation of the pressure gradient of embolic protection devices
  78. Computer assistance in femoral derotation osteotomy: a bottom-up approach
  79. Automatic depth scanning system for 3D infrared thermography
  80. A service for monitoring the quality of intraoperative cone beam CT images
  81. Resectoscope with an easy to use twist mechanism for improved handling
  82. In vitro simulation of distribution processes following intramuscular injection
  83. Adjusting inkjet printhead parameters to deposit drugs into micro-sized reservoirs
  84. A flexible standalone system with integrated sensor feedback for multi-pad electrode FES of the hand
  85. Smart control for functional electrical stimulation with optimal pulse intensity
  86. Tactile display on the remaining hand for unilateral hand amputees
  87. Effects of sustained electrical stimulation on spasticity assessed by the pendulum test
  88. An improved tracking framework for ultrasound probe localization in image-guided radiosurgery
  89. Improvement of a subviral particle tracker by the use of a LAP-Kalman-algorithm
  90. Learning discriminative classification models for grading anal intraepithelial neoplasia
  91. Regularization of EIT reconstruction based on multi-scales wavelet transforms
  92. Assessing MRI susceptibility artefact through an indicator of image distortion
  93. EyeGuidance – a computer controlled system to guide eye movements
  94. A framework for feedback-based segmentation of 3D image stacks
  95. Doppler optical coherence tomography as a promising tool for detecting fluid in the human middle ear
  96. 3D Local in vivo Environment (LivE) imaging for single cell protein analysis of bone tissue
  97. Inside-Out access strategy using new trans-vascular catheter approach
  98. US/MRI fusion with new optical tracking and marker approach for interventional procedures inside the MRI suite
  99. Impact of different registration methods in MEG source analysis
  100. 3D segmentation of thyroid ultrasound images using active contours
  101. Designing a compact MRI motion phantom
  102. Cerebral cortex classification by conditional random fields applied to intraoperative thermal imaging
  103. Classification of indirect immunofluorescence images using thresholded local binary count features
  104. Analysis of muscle fatigue conditions using time-frequency images and GLCM features
  105. Numerical evaluation of image parameters of ETR-1
  106. Fabrication of a compliant phantom of the human aortic arch for use in Particle Image Velocimetry (PIV) experimentation
  107. Effect of the number of electrodes on the reconstructed lung shape in electrical impedance tomography
  108. Hardware dependencies of GPU-accelerated beamformer performances for microwave breast cancer detection
  109. Computer assisted assessment of progressing osteoradionecrosis of the jaw for clinical diagnosis and treatment
  110. Evaluation of reconstruction parameters of electrical impedance tomography on aorta detection during saline bolus injection
  111. Evaluation of open-source software for the lung segmentation
  112. Automatic determination of lung features of CF patients in CT scans
  113. Image analysis of self-organized multicellular patterns
  114. Effect of key parameters on synthesis of superparamagnetic nanoparticles (SPIONs)
  115. Radiopacity assessment of neurovascular implants
  116. Development of a desiccant based dielectric for monitoring humidity conditions in miniaturized hermetic implantable packages
  117. Development of an artifact-free aneurysm clip
  118. Enhancing the regeneration of bone defects by alkalizing the peri-implant zone – an in vitro approach
  119. Rapid prototyping of replica knee implants for in vitro testing
  120. Protecting ultra- and hyperhydrophilic implant surfaces in dry state from loss of wettability
  121. Advanced wettability analysis of implant surfaces
  122. Patient-specific hip prostheses designed by surgeons
  123. Plasma treatment on novel carbon fiber reinforced PEEK cages to enhance bioactivity
  124. Wear of a total intervertebral disc prosthesis
  125. Digital health and digital biomarkers – enabling value chains on health data
  126. Usability in the lifecycle of medical software development
  127. Influence of different test gases in a non-destructive 100% quality control system for medical devices
  128. Device development guided by user satisfaction survey on auricular vagus nerve stimulation
  129. Empirical assessment of the time course of innovation in biomedical engineering: first results of a comparative approach
  130. Effect of left atrial hypertrophy on P-wave morphology in a computational model
  131. Simulation of intracardiac electrograms around acute ablation lesions
  132. Parametrization of activation based cardiac electrophysiology models using bidomain model simulations
  133. Assessment of nasal resistance using computational fluid dynamics
  134. Resistance in a non-linear autoregressive model of pulmonary mechanics
  135. Inspiratory and expiratory elastance in a non-linear autoregressive model of pulmonary mechanics
  136. Determination of regional lung function in cystic fibrosis using electrical impedance tomography
  137. Development of parietal bone surrogates for parietal graft lift training
  138. Numerical simulation of mechanically stimulated bone remodelling
  139. Conversion of engineering stresses to Cauchy stresses in tensile and compression tests of thermoplastic polymers
  140. Numerical examinations of simplified spondylodesis models concerning energy absorption in magnetic resonance imaging
  141. Principle study on the signal connection at transabdominal fetal pulse oximetry
  142. Influence of Siluron® insertion on model drug distribution in the simulated vitreous body
  143. Evaluating different approaches to identify a three parameter gas exchange model
  144. Effects of fibrosis on the extracellular potential based on 3D reconstructions from histological sections of heart tissue
  145. From imaging to hemodynamics – how reconstruction kernels influence the blood flow predictions in intracranial aneurysms
  146. Flow optimised design of a novel point-of-care diagnostic device for the detection of disease specific biomarkers
  147. Improved FPGA controlled artificial vascular system for plethysmographic measurements
  148. Minimally spaced electrode positions for multi-functional chest sensors: ECG and respiratory signal estimation
  149. Automated detection of alveolar arches for nasoalveolar molding in cleft lip and palate treatment
  150. Control scheme selection in human-machine- interfaces by analysis of activity signals
  151. Event-based sampling for reducing communication load in realtime human motion analysis by wireless inertial sensor networks
  152. Automatic pairing of inertial sensors to lower limb segments – a plug-and-play approach
  153. Contactless respiratory monitoring system for magnetic resonance imaging applications using a laser range sensor
  154. Interactive monitoring system for visual respiratory biofeedback
  155. Development of a low-cost senor based aid for visually impaired people
  156. Patient assistive system for the shoulder joint
  157. A passive beating heart setup for interventional cardiology training
Downloaded on 8.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/cdbme-2016-0044/html
Scroll to top button