Home Destructive and nondestructive tests formulation for concrete containing polyolefin fibers
Article Open Access

Destructive and nondestructive tests formulation for concrete containing polyolefin fibers

  • Ihab S. Saleh EMAIL logo , Muthana Sh. Mahdi and Mohammed F. Ojaimi
Published/Copyright: December 2, 2022
Become an author with De Gruyter Brill

Abstract

Polyolefin fiber is a new type of fiber that was used in concrete to improve some of the poor properties of concrete including; tensile strength, ductility, and fracture energy. In this research, the contribution of Polyolefin fiber in improving the properties of hardened concrete was examined by adding polyolefin fibers to mix with different fiber content. The polypropylene fibers were added as a ratio of 0.5, 0.75, 1.0, 1.5, and 2% of concrete volume. Destructive and non-destructive tests were carried out: slump, compression, splitting, and bending, Schmidt Hammer, and ultrasonic pulse velocity tests. The results showed that, as the polyolefin fiber content increases, the workability of concrete reduces dramatically. The experimental findings demonstrate that the concrete tensile strength and ductility were improved by a small improvement in overall compressive strength. The results show that the compressive strength increased gradually with the increase in fiber content of up to 1.5%, and then, the compressive strength starts to decrease. However, the tensile strength increases continuously with the fiber content increasing. A good relationship was obtained between the destructive and nondestructive tests.

1 Introduction

Concrete is a relatively brittle material; therefore, the addition of fibers to concrete makes it more ductile, homogenous, and isotropic [1]. Variable fibers, such as carbon, alcohol polyvinyl, steel and glass fibers, will potentially increase strength due to strong modulation, whereas low resistance fibers like polypropylene, nylon, and acrylic increase the ductility and consequently, minimize cracking [2]. In the construction of the building, the mechanical properties of concrete have been improved by fiber-reinforced concrete. Workability, strength of compression, tension [3,4,5] polyethylene, and polypropylene are commonly used polyolefins and the fastest growing class of polymers, due to high development and low manufacturing costs in relation to plastics. Polyolefin fibers have wide usage in modern manufacturing. Low cost, good chemical tolerance, high resistance, and sustainability have been used extensively. Polyolefin fiber with a high tensile resistance and excellent corrosion resistance is typically solid [6,7]. Polyolefin-reinforced concrete has excellent post-cracking behavior. The total costs of the material can be greatly reduced by plastic fibers and the corrosion issues of SF can be prevented. In addition, several carbon footprint reductions have also been recorded as opposed to steel production [17]. Polyolefin fibers have been attractive to scientists in the concrete industries. Studies to eliminate stainless steel corrosion are also underway [8,9,10,11,12,13]. Based on the major advantages such as increasing structural strength, polyolefin fibers are commonly used [14,15]. Polyolefin fibers, which have no water reactions, are less weight than steel fibers. Despite steel degradation and cracks, polyolefin fiber-reinforced concrete exhibits stronger performance [16]. The structure and rugged construction of Polyolefin fibers improve the bonding properties with concrete. Reinforced concrete polyolefin fiber also has a higher bending power. Researchers have conducted several years of laboratory research on certain of the following studies, which include the advantages of polyolefin fibers in ordinary concrete, lightweight concrete, foamed concrete, and highly efficient concrete. Balaguru and Shah [17] have reported that, in general, there has been a small influence on compressive strength where the steel-fiber in the concrete is added, although in some cases others feel that the compressive strength has increased up to a maximum of 25%. Furthermore, significant improvements are normally found in tension and toughness. Furlan and De Hanai [18] have stated that the characteristics of concrete are highly affected when a large volume of fibers is added. At the same time, the authors have found that the tensile strength of concrete is not significantly modified when the volume of fibers added is lower than 2%. Meddah and Bencheikh [19] The feasibility of adding by-product fiber from metallic and polypropylene as the strengthening of standard concrete was addressed. The effects on mechanical properties of fiber-reinforced concrete have been experimentally studied by integrating different waste metallic fibers and waste polypropylene fibers (WPFs). The effect of the compressive, flexural strength, and hardness of reinforced fibers by the shape, volume, and length of waste fibers are evaluated; the results showed that the WPF diminished compressive strength, especially when using long, high-volume fibers.

2 Experimental program

The research experimental procedure is intended for fresh and reinforced concrete. The slump test is used to determine concrete workability. Tests for hardened concrete include preparation and evaluation of 150 mm × 150 mm × 150 mm concrete cubes, preparation, and measuring of concrete Prism of 100 mm × 100 mm × 350 mm as well as preparation and casting of 300 mm×150 mm concrete cylinders. The polyolefin fibers used in this study are in volume proportions of 0.5, 0.75, 1.0, 1.5, and 2.0% of the concrete volume.

2.1 Materials

Depending on the location, convenience, affordability, and availability, the following materials such as cement and components are used:

2.1.1 Cement

Ordinary Portland cement conforms to ASTM C150-15 [20] specification requirements and was used in this study. The chemical composition and physical test results of the cement used are listed in Table 1.

Table 1

Chemical composition and physical test results of the cement used

Physical test results
Test Unit Test result ASTM C 150 – 15 Limits
O.P.C – Type I
Initial setting time Minute 139 45 –375
Compressive strength MPa
3 Days age 15.7 12 min
7 Days age 23.6 19 min
Chemical test results
Test Test result ASTM C 150 – 15 Limits
O.P.C – Type I
Ratio% SiO2 18.5
Al2O3 4.1
Fe2O3 2.7
CaO 46.9
MgO 3.66 6 max.
C3A 3.3
SO3 2.25 3.0 max.
L.O.I % 2.75 3 max.
I.R % 0.52 0.75 max.

2.1.2 Fine aggregate

Natural sand was used in the city of Basrah in the Sanam Mountain zone. Table 2 displays fine aggregate grading and ASTM C33-13 limits [21], and Table 3 shows the physical and chemical test results of the used fine aggregate.

Table 2

Grading of the fine aggregate used

Sieve size (mm) Percent passing
Fine aggregate Limits of ASTM C33 [21]
9.5 100 100
4.75 98 95–100
2.36 85 80–100
1.18 66 50–85
0.6 40 25–60
0.3 13 5–30
0.15 2 0–10
0.075 1.5 0–3
Table 3

Properties of the fine aggregate

Test Result
Fineness modulus 2.91
Specific gravity 2.65
Sulfate content (SO3), (%) 0.33
Absorption, (%) 1.2
Loose bulk density (kg/m3) 1,645

2.1.3 Coarse aggregate

Crushed gravel with size (19–4.75) mm was used from the area of the Sanam mountains in Basrah town. Table 4 shows coarse aggregate grading complies with ASTM C33-13 [21]. The Specific gravity, content of sulfate, chloride, and absorption of the coarse aggregate are described in Table 5.

Table 4

Grading of the coarse aggregate used

Percent passing
Sieve size, mm Coarse aggregate used Limits of ASTM C33-13 [21]
25 100 100
19 92 90–100
9.5 39 20–55
4.75 4 0–10
2.36 1 0–5
0.075 0.4 0–1
Table 5

Physical and chemical test results of the coarse aggregate used

Test Result
Specific gravity 2.61
Sulfate content (SO3) 0.083%
Chloride content (Cl) 0.097%
Absorption 0.85%
Loose bulk density (kg/m3) 1,588

2.1.4 Polyolefin fibers

Polyolefin fibers consist mostly of macromolecules and saturated aliphatic (Figure 1). A polyolefin is classified as a produced fiber in which any synthetic long-chain polymer composed of a mass of ethene, propene, or other olefin units at least 85% is formed by the fiber former. In this study, SikaFiber® Force-60 was used. Table 6 displays the SikaFiber® Force-60 technical info.

Figure 1 
                     Polyolefin Fiber – SikaFiber® Force-60.
Figure 1

Polyolefin Fiber – SikaFiber® Force-60.

Table 6

Technical data of SikaFiber® Force-60

Physical properties Test results
Density 910 kg/m3
Dimension Length ∼60 mm, equivalent diameter ∼0,84 mm
Tensile strength ∼430 MPa
Modulus of elasticity in tension 6 GPa

2.1.5 Water

For mixing and curing of concrete, ordinary drinking water was used.

2.1.6 Superplasticizer

Superplasticizer (HWRA) based on polycarboxylic ether is used for manufacture of high-performance concrete. Sika F-180g is one of the latest copolymers in the generation. The ASTM C494(2004) [22], Type A, and Type F are compliant.

2.2 Mix proportions and concrete properties

In this study, there are only one mix proportion which was used with different polyolefin fiber content as summarized in Table 7, in order to clarify the effect of fiber content on the concrete workability; constant water cement ration (w/c) of 0.39 was used. For the control mix (zero fiber content), the slump and compressive strength target was 200 mm and 40 MPa, respectively. Superplasticizer was used to achieved goals of slump target (Figure 2).

Table 7

Mix proportion and polyolefin fiber percentage

Mix No. Coarse aggregate (kg/m3) Fine aggregate (kg/m3) Cement (kg/m3) Fiber (kg/m3) Fiber (%)
1 1,112 667 445 0 0
2 1,112 667 445 4.45 0.5
3 1,112 667 445 6.825 0.75
4 1,112 667 445 9.1 1
5 1,112 667 445 13.65 1.5
6 1,112 667 445 18.2 2
Figure 2 
                  Polyolefin fiber in concrete mix – SikaFiber® Force-6.
Figure 2

Polyolefin fiber in concrete mix – SikaFiber® Force-6.

3 Test method

The hardened concrete compressive strength test was conducted on the basis of the BS EN 12390-3:2009 model system [23], on the cubic component with dimensions 150 mm × 150 mm × 150 mm. Molded casting reveals in Figure 3. After 7 and 28 days of storage in water, six compressive specimens were produced for each blend. Processing samples were carried out in pool water. The employed machine for determination of the compressive strength had a capacity of 2,000 kN. Concrete Prism with dimensions of 100 mm × 100 mm × 350 mm and the test was conducted in accordance with the standard ASTM C78/C78M method [24] to assess the flexural strength of hardened concrete. After 28 days of specimen care, the examination was performed. The splitting power tensile was calculated in the cylindrical specimens with size 300 to 150 mm following 28 days of storage in water, according to standard ASTM C496/C496M method [25] on cylindrical specimens with dimensions of 300 × 150 mm after 28 days of storage in water.

Figure 3 
               Test specimen molds.
Figure 3

Test specimen molds.

The rebound number was measured of the 150 mm cube specimens using Schmidt Hammer according to ASTM C 805-02 [26]. The ultrasonic pulse velocities of the concrete cubes were measured according to ASTM C597-02 [27] using transducers with frequency 54 kHz, as shown in Figure 4.

Figure 4 
               Nondestructive tests.
Figure 4

Nondestructive tests.

4 Results and discussion

This study leads to the following results:

4.1 Fresh concrete

Table 8 shows the new concrete characteristics for each mixture form (slump value). The results demonstrate clearly that the concrete containing polypropylene fibers, in comparison to standard concrete, has lower slump values. The slump decreased as the fiber content rises as shown in Figure 5. The resistance strength of concrete containing polyolefin fiber can be the cause of this behavior.

Table 8

Slump of concrete mixes with different contents of polyolefin fibers

Specimen symbol Polyolefin fiber % Slump (mm)
F-1 0 220
B-2 0.5 200
B-3 0.75 170
B-1 1 140
B-4 1.5 100
B-5 2 80
Figure 5 
                  Slump of fresh concrete containing polyolefin percent in different mixes.
Figure 5

Slump of fresh concrete containing polyolefin percent in different mixes.

4.2 Hardened concrete

Destructive and non-destructive tests were carried out to establish the mechanical characteristics of the concrete that contains polyolefin fibers. Compressive power, bending strength, tensile cracking strength, Schmidt Hammer, and ultrasonic pulse speed (UPV) have been tested.

4.2.1 Compressive strength

For three samples per mixture, the compressive strength of the samples was measured at 7 and 28 days. Furthermore, the findings of concrete containing polyol Iven fiber were tested for non-destructive use. In the compressive strength of concrete with and without polyol Iven fibers, Schmitt Hummer and Ultrasound Testing are used. The overall compressive intensity results are shown in Table 9. The compressive strength of B-2, B-3, B-4, and B5 at 7 days shows increase in compressive strength when compared with plain concrete F-1. The ratios of increasing were 1.06, 1.09, 1.1, 1.05, and 1.01 respectively, while the ratios at 28 days were 1.11, 1.13, 1.28, 1.04 and 0.98 respectively, as shown in Figure 6.

Table 9

Compressive strength of concrete containing polyolefin fibers

Specimen symbol Polyolefin fiber % Compressive strength (MPa) at 7 days Compressive strength (MPa) at 28 days
F-1 0 41.76 44.3
B-2 0.5 44.63 49.15
B-3 0.75 45.73 50.36
B-1 1 46.27 57.07
B-4 1.5 44.0 46.5
B-5 2 42.46 43.66
Figure 6 
                     Compressive strength of concrete containing polyolefin % in different mixes.
Figure 6

Compressive strength of concrete containing polyolefin % in different mixes.

4.2.2 Flexural strength

The tested concrete prisms at the age of 28 were performed on three samples from each concrete mix as in Table 10. Clearly, the increase in the polyolefin fiber content of the concrete results in a considerable increase in the bending power of cement, as shown in Figure 7. If the polyolefin concrete fiber content rises from 0 to 2%, the bending power rises by about 1.28, 1.56, 1.67, 1.83, and 2%. This may be due to the fiber–matrix interface, with better links and fewer air voids. The inclusion of polyolefin fibers in the concrete matrix seems to be a major barrier to the spread of fine cracks against the load. The delayed development of the primary crack that induces failure is responsible for this resistance. Moreover, polyolefin fibers, which results in increasing intensity, can reduce the tension levels accumulated around the cracks.

Table 10

Effect of polyolefin fiber on flexural strength of concrete

Specimen symbol Polyolefin fiber percent % Flexural strength (MPa)
F-1 0 4.41
B-2 0.5 5.65
B-3 0.75 6.87
B-1 1 7.36
B-4 1.5 8.09
B-5 2 8.98
Figure 7 
                     Flexural strength of concrete containing polyolefin % in different mixes.
Figure 7

Flexural strength of concrete containing polyolefin % in different mixes.

4.2.3 Splitting tensile strength

The strength of the concrete cylinder was measured on three samples of every concrete mix for 28 days, and the average results are given in Table 11. Figure 8 shows the results of dividing the tensile solidity of polyolefin fiber-containing concrete. The polyolefin fiber ratio rose from 0 to 2% to show a substantial improvement in the values of the fracturing power of tensile. The divisor intensity levels were 1.23, 1.38, 1.45, 1.51, and 1.66% more than standard concrete F-1, respectively. This conduct goes beyond polyolefin fibers’ capacity to diminish the thick splits of the concrete. As splitting happened, fiber was transmitted from the matrix through the fibers, and hence, it eventually served the full load, which crossed the broken portions of the concrete matrix. The tension conversion enhanced the fiber-reinforced concrete’s tensile strength and thereby strengthened the fracturing strength of the reinforced concrete on the unreinforced controller. Duration, dosage, and shape of polyolefin fiber are the principal effects on the splitting tensile power. Polyolefin fiber with scalloped shape may provide the best bond to the cementitious matrix and highly increase the splitting tensile strength.

Table 11

Effect of polyolefin fiber on splitting tensile strength

Specimen symbol Polyolefin fiber % Splitting tensile strength (MPa)
F-1 0 2.87
B-2 0.5 3.54
B-3 0.75 3.96
B-1 1 4.16
B-4 1.5 4.34
B-5 2 4.77
Figure 8 
                     Splitting tensile strength of concrete containing polyolefin % in different mixes.
Figure 8

Splitting tensile strength of concrete containing polyolefin % in different mixes.

4.2.4 Nondestructive tests

Table 12 shows that the rebound number and UPV have risen to 1% with the growth of fiber content, but after that it was reduced as the content of fiber. The polyolefin fiber tends to influence compressive power, rebound, and UPV number, as shown in Figures 9 and 10. When the polyolefin fibers reach 1.0%, the compressive resistance falls as a result of lower concrete cohesion and compacting difficulty of the concrete cubes. Depending on the earlier, the fiber quality of the prediction of compressive intensity is from 0 to 1%. Figure 11 reveals that the compressive strength of concrete and the ultrasonic pulse velocity of concrete are related regardless of the difference in fiber content; the increase in one is similarly reflected in an increase in the other. From this figure, the relationship between cube compressive strength (f cu) and the ultrasonic pulse velocity (V) is obtained as given in equation (1).

(1) f cu = 0 . 0026 V 2 26 . 254 V 1 + 65 , 922 .

Table 12

Compressive strength and results of nondestructive tests at 28 days

Specimen symbol Polyolefin fiber content (%) Compressive strength (MPa) Rebound number (RN) Compressive strength estimated by RN (MPa) UPV (m/s) Compressive strength estimated by UPV (MPa)
F-1 0 44.3 37.7 44.5 5,035 57.1
B-2 0.5 49.15 38.3 47.1 5,060 50.4
B-3 0.75 50.36 39.3 53.5 5,075 49.2
B-1 1 57.07 39.7 56.8 5,088 46.5
B-4 1.5 46.5 37.5 43.8 5,050 44.3
B-5 2 43.66 36.3 41.9 4,947 43.7
Figure 9 
                     Rebound number and fibers content relationship.
Figure 9

Rebound number and fibers content relationship.

Figure 10 
                     Ultrasonic pulse velocity and fibers content relationship.
Figure 10

Ultrasonic pulse velocity and fibers content relationship.

Figure 11 
                     Ultrasonic pulse velocity and compressive strength relationship for concrete with fiber content from 0 to 1%.
Figure 11

Ultrasonic pulse velocity and compressive strength relationship for concrete with fiber content from 0 to 1%.

Figure 12 describes the relationship between the rebound number and the compressive strength of the concrete with different fiber content. Test findings for mixtures made of concrete fiber containing polyolefin have shown a positive association between compressive strength and rebound number. The relationship between the cube compressive strength (f cu) and the rebound number (RN) is determined as shown in the equation (2).

(2) f cu = 1 . 2681 RN 2 92 . 009 RN + 1 , 710 .

Figure 12 
                     Rebound number and compressive strength relationship for concrete with fiber content from 0 to 1%.
Figure 12

Rebound number and compressive strength relationship for concrete with fiber content from 0 to 1%.

5 Conclusions

The main objective of this study was improving the concrete mix properties by adding the olefin fibers in order to improving the compressive, flexural, and splitting strength. The practical tests in 7 and 28 day of samples ages were recorded. Consequently, and depending on the investigation finding in this study, it can be inferred that the slump in horn with poor workability and compaction of concrete decreases considerably as that of the polyolefin fibers increase. Polyolefin fibers have a little influence on the frequency of the compressive strength. This includes a drop in the compressive capacity of the polyolefin ratio to over 1.5%, while as the polypropylene fiber content rise up to 2%, the concrete ductility improved dramatically. The ultimate tensile strength was not increased by further improvement in polypropylene fibers (values of more than 1.5 vol.%), but much more ductile connections. The compressive strength of concrete mixtures that produce polyolefin fibers with rebound number and ultrasonic pulse velocity is well established. The effect of adding polyolefin fibers can be observed clearly by the considerable increase in the concrete compressive strength as well as the rising of concrete ductility which reflected on the flexural resisting of the concrete mix with fibers. The improving of the fresh and hardened concrete can be demonstrated as the result of fiber’s action which increases the bond between the concrete mix contents; consequently, the concrete shows better properties.

  1. Conflict of interest: Authors state no conflict of interest.

References

[1] ACI Committee 544. Measurements of properties of fiber reinforced concrete. ACI Mater J. 1988;85(6):583–93.10.14359/2355Search in Google Scholar

[2] Pakravan HR, Latifi M, Jamshidi M. Hybrid short fiber reinforcement system in concrete: A review. Constr Build Mater. 2017;142:280–94.10.1016/j.conbuildmat.2017.03.059Search in Google Scholar

[3] Konig G. New concepts for high performance concrete with improved ductility. proceedings of the 12th FIP Congress on Challenges for Concrete in the Next Millennium. Netherlands: 1998. p. 49–53.Search in Google Scholar

[4] Ramezanianpour AA, Najimi M, Pourkhorshidi A. The role of polypropylene fibers on concrete properties. First Disaster Management Symposium. University of Tehran; 2006. p. 542–9.Search in Google Scholar

[5] Breitenbucher R. High strength concrete C 105 with increased fiber resistance due to polypropylene fibers. 4th International Symposium on the Utilization of hIgh Strength-high Performance Concrete. Paris: 1996. p. 571–7.Search in Google Scholar

[6] Pyle RW. Product and method for incorporating synthetic polymer fibers into cement mixtures. U.S. Patent 6. 258, 10 July 2001. p. 159.Search in Google Scholar

[7] Islam GS, Gupta SD. Evaluating plastic shrinkage and permeability of polyolefin fibber reinforced concrete. Int J Sustain Built Env. 2016;5:345–54.10.1016/j.ijsbe.2016.05.007Search in Google Scholar

[8] Alizade E, Jandaghi AF, Zabihi S. Effect of steel fiber corrosion on mechanical properties of steel fiber reinforced concrete. Asian J Civ Eng. 2016;17:147–58.Search in Google Scholar

[9] Berrocal CG, Lundgren K, Löfgren I. Influence of steel fibers on corrosion of reinforcement in concrete in chloride environments: A review. Proceedings of the 7th International Conference Fibre Concrete. Prague, Czech Republic: 2013. p. 12–3.Search in Google Scholar

[10] Anandan S, Manoharan SV, Sengottian T. Corrosion effects on the strength properties of steel fibre reinforced concrete containing slag and corrosion inhibitor. Int J Corros. 2014;2014:595040.10.1155/2014/595040Search in Google Scholar

[11] Granju JL, Balouch SU. Corrosion of steel fiber reinforced concrete from the cracks. Cem Concr Res. 2005;35:572–7.10.1016/j.cemconres.2004.06.032Search in Google Scholar

[12] Mihashi H, Ahmed SFU, Kobayakawa A. Corrosion of reinforcement steel in steel fiber reinforced concrete structures. J Adv Concr Tech. 2011;9:159–67.10.3151/jact.9.159Search in Google Scholar

[13] Bagherzadeh R, Pakravan HR, Sadeghi AH, Latifi M, Merati AA. An investigation on adding polypropylene fibers to reinforce lightweight cement composites. J Eng Fibers Fabr. 2012;7:13–9.10.1177/155892501200700410Search in Google Scholar

[14] Tagnit A, Vanhove Y, Petrov N. Microstructural analysis of the bond mechanism between polyolefin fibers and cement pastes. Cem Concr Res. 2005;35:364370.10.1016/j.cemconres.2004.05.046Search in Google Scholar

[15] Neeley BD, O’Neil EF. Polyolefin fiber reinforced concrete. Proceedings of the Materials Engineering Conference: Materials for the New Millennium. 1, Washington, DC, USA: November 1996. p. 113–122.Search in Google Scholar

[16] Lin W, Cheng A. Effect of polyolefin fibers and supplementary cementitious materials on corrosion behavior of cement-based composites. J Inorg Organomet Polym. 2013;23:888–96.10.1007/s10904-013-9866-1Search in Google Scholar

[17] Balaguru PN, Shah SP. Fiber reinforced cement composites. Singapore: McGrawHill. Inc, 1992.Search in Google Scholar

[18] Furlan S, De Hanai J. Shear behavior of fiber reinforced concrete. Cem Compos. 1997;19(4):359–66.10.1016/S0958-9465(97)00031-0Search in Google Scholar

[19] Meddah MS, Bencheikh M. Properties of concrete reinforced with different kinds of industrial waste fiber materials. Constr Build Mater 23(10):3196–205.10.1016/j.conbuildmat.2009.06.017Search in Google Scholar

[20] Iraqi Standards No.5/1984. Ordinary Portland cement. Ministry of Housing and Construction, Baghdad; 2004.Search in Google Scholar

[21] Iraqi Standards No.45/1984. Aggregate from Natural Sources for Concrete and Construction. Ministry of Housing and Construction, Baghdad; 2004.Search in Google Scholar

[22] ASTM C 494-04. Standard specification for Chemical Admixtures for Concrete. ASTM International, American Society of Testing Materials, USA. 4.2, 2004.Search in Google Scholar

[23] BS EN 12390-3, 2009, “Methods for Determination of Compressive Strength of Concrete Cubes,” published by BSI.Search in Google Scholar

[24] ASTM C78-02. Standard Test Method for Flexural Strength of Concrete (Using Simple Beam with Third-point Loading). 4.2, 2002. p. 1–3.Search in Google Scholar

[25] ASTM C496/C496M-04. Standard Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens. 4.2, 2004. p. 1–5.Search in Google Scholar

[26] ASTM C 805-02. Standard Test Method for Rebound Number of Hardened Concrete. 4.2, USA: ASTM International, American Society of Testing Materials; 2002.Search in Google Scholar

[27] ASTM C 597-02. Standard Test Method for Pulse Velocity through Concrete. 4.2, USA: ASTM International. American Society of Testing Materials; 2002.Search in Google Scholar

Received: 2022-04-01
Revised: 2022-07-24
Accepted: 2022-08-01
Published Online: 2022-12-02

© 2022 the author(s), published by De Gruyter

This work is licensed under the Creative Commons Attribution 4.0 International License.

Articles in the same Issue

  1. Regular Articles
  2. Performance of a horizontal well in a bounded anisotropic reservoir: Part I: Mathematical analysis
  3. Key competences for Transport 4.0 – Educators’ and Practitioners’ opinions
  4. COVID-19 lockdown impact on CERN seismic station ambient noise levels
  5. Constraint evaluation and effects on selected fracture parameters for single-edge notched beam under four-point bending
  6. Minimizing form errors in additive manufacturing with part build orientation: An optimization method for continuous solution spaces
  7. The method of selecting adaptive devices for the needs of drivers with disabilities
  8. Control logic algorithm to create gaps for mixed traffic: A comprehensive evaluation
  9. Numerical prediction of cavitation phenomena on marine vessel: Effect of the water environment profile on the propulsion performance
  10. Boundary element analysis of rotating functionally graded anisotropic fiber-reinforced magneto-thermoelastic composites
  11. Effect of heat-treatment processes and high temperature variation of acid-chloride media on the corrosion resistance of B265 (Ti–6Al–4V) titanium alloy in acid-chloride solution
  12. Influence of selected physical parameters on vibroinsulation of base-exited vibratory conveyors
  13. System and eco-material design based on slow-release ferrate(vi) combined with ultrasound for ballast water treatment
  14. Experimental investigations on transmission of whole body vibration to the wheelchair user's body
  15. Determination of accident scenarios via freely available accident databases
  16. Elastic–plastic analysis of the plane strain under combined thermal and pressure loads with a new technique in the finite element method
  17. Design and development of the application monitoring the use of server resources for server maintenance
  18. The LBC-3 lightweight encryption algorithm
  19. Impact of the COVID-19 pandemic on road traffic accident forecasting in Poland and Slovakia
  20. Development and implementation of disaster recovery plan in stock exchange industry in Indonesia
  21. Pre-determination of prediction of yield-line pattern of slabs using Voronoi diagrams
  22. Urban air mobility and flying cars: Overview, examples, prospects, drawbacks, and solutions
  23. Stadiums based on curvilinear geometry: Approximation of the ellipsoid offset surface
  24. Driftwood blocking sensitivity on sluice gate flow
  25. Solar PV power forecasting at Yarmouk University using machine learning techniques
  26. 3D FE modeling of cable-stayed bridge according to ICE code
  27. Review Articles
  28. Partial discharge calibrator of a cavity inside high-voltage insulator
  29. Health issues using 5G frequencies from an engineering perspective: Current review
  30. Modern structures of military logistic bridges
  31. Retraction
  32. Retraction note: COVID-19 lockdown impact on CERN seismic station ambient noise levels
  33. Special Issue: Trends in Logistics and Production for the 21st Century - Part II
  34. Solving transportation externalities, economic approaches, and their risks
  35. Demand forecast for parking spaces and parking areas in Olomouc
  36. Rescue of persons in traffic accidents on roads
  37. Special Issue: ICRTEEC - 2021 - Part II
  38. Switching transient analysis for low voltage distribution cable
  39. Frequency amelioration of an interconnected microgrid system
  40. Wireless power transfer topology analysis for inkjet-printed coil
  41. Analysis and control strategy of standalone PV system with various reference frames
  42. Special Issue: AESMT
  43. Study of emitted gases from incinerator of Al-Sadr hospital in Najaf city
  44. Experimentally investigating comparison between the behavior of fibrous concrete slabs with steel stiffeners and reinforced concrete slabs under dynamic–static loads
  45. ANN-based model to predict groundwater salinity: A case study of West Najaf–Kerbala region
  46. Future short-term estimation of flowrate of the Euphrates river catchment located in Al-Najaf Governorate, Iraq through using weather data and statistical downscaling model
  47. Utilization of ANN technique to estimate the discharge coefficient for trapezoidal weir-gate
  48. Experimental study to enhance the productivity of single-slope single-basin solar still
  49. An empirical formula development to predict suspended sediment load for Khour Al-Zubair port, South of Iraq
  50. A model for variation with time of flexiblepavement temperature
  51. Analytical and numerical investigation of free vibration for stepped beam with different materials
  52. Identifying the reasons for the prolongation of school construction projects in Najaf
  53. Spatial mixture modeling for analyzing a rainfall pattern: A case study in Ireland
  54. Flow parameters effect on water hammer stability in hydraulic system by using state-space method
  55. Experimental study of the behaviour and failure modes of tapered castellated steel beams
  56. Water hammer phenomenon in pumping stations: A stability investigation based on root locus
  57. Mechanical properties and freeze-thaw resistance of lightweight aggregate concrete using artificial clay aggregate
  58. Compatibility between delay functions and highway capacity manual on Iraqi highways
  59. The effect of expanded polystyrene beads (EPS) on the physical and mechanical properties of aerated concrete
  60. The effect of cutoff angle on the head pressure underneath dams constructed on soils having rectangular void
  61. An experimental study on vibration isolation by open and in-filled trenches
  62. Designing a 3D virtual test platform for evaluating prosthetic knee joint performance during the walking cycle
  63. Special Issue: AESMT-2 - Part I
  64. Optimization process of resistance spot welding for high-strength low-alloy steel using Taguchi method
  65. Cyclic performance of moment connections with reduced beam sections using different cut-flange profiles
  66. Time overruns in the construction projects in Iraq: Case study on investigating and analyzing the root causes
  67. Contribution of lift-to-drag ratio on power coefficient of HAWT blade for different cross-sections
  68. Geotechnical correlations of soil properties in Hilla City – Iraq
  69. Improve the performance of solar thermal collectors by varying the concentration and nanoparticles diameter of silicon dioxide
  70. Enhancement of evaporative cooling system in a green-house by geothermal energy
  71. Destructive and nondestructive tests formulation for concrete containing polyolefin fibers
  72. Quantify distribution of topsoil erodibility factor for watersheds that feed the Al-Shewicha trough – Iraq using GIS
  73. Seamless geospatial data methodology for topographic map: A case study on Baghdad
  74. Mechanical properties investigation of composite FGM fabricated from Al/Zn
  75. Causes of change orders in the cycle of construction project: A case study in Al-Najaf province
  76. Optimum hydraulic investigation of pipe aqueduct by MATLAB software and Newton–Raphson method
  77. Numerical analysis of high-strength reinforcing steel with conventional strength in reinforced concrete beams under monotonic loading
  78. Deriving rainfall intensity–duration–frequency (IDF) curves and testing the best distribution using EasyFit software 5.5 for Kut city, Iraq
  79. Designing of a dual-functional XOR block in QCA technology
  80. Producing low-cost self-consolidation concrete using sustainable material
  81. Performance of the anaerobic baffled reactor for primary treatment of rural domestic wastewater in Iraq
  82. Enhancement isolation antenna to multi-port for wireless communication
  83. A comparative study of different coagulants used in treatment of turbid water
  84. Field tests of grouted ground anchors in the sandy soil of Najaf, Iraq
  85. New methodology to reduce power by using smart street lighting system
  86. Optimization of the synergistic effect of micro silica and fly ash on the behavior of concrete using response surface method
  87. Ergodic capacity of correlated multiple-input–multiple-output channel with impact of transmitter impairments
  88. Numerical studies of the simultaneous development of forced convective laminar flow with heat transfer inside a microtube at a uniform temperature
  89. Enhancement of heat transfer from solar thermal collector using nanofluid
  90. Improvement of permeable asphalt pavement by adding crumb rubber waste
  91. Study the effect of adding zirconia particles to nickel–phosphorus electroless coatings as product innovation on stainless steel substrate
  92. Waste aggregate concrete properties using waste tiles as coarse aggregate and modified with PC superplasticizer
  93. CuO–Cu/water hybrid nonofluid potentials in impingement jet
  94. Satellite vibration effects on communication quality of OISN system
  95. Special Issue: Annual Engineering and Vocational Education Conference - Part III
  96. Mechanical and thermal properties of recycled high-density polyethylene/bamboo with different fiber loadings
  97. Special Issue: Advanced Energy Storage
  98. Cu-foil modification for anode-free lithium-ion battery from electronic cable waste
  99. Review of various sulfide electrolyte types for solid-state lithium-ion batteries
  100. Optimization type of filler on electrochemical and thermal properties of gel polymer electrolytes membranes for safety lithium-ion batteries
  101. Pr-doped BiFeO3 thin films growth on quartz using chemical solution deposition
  102. An environmentally friendly hydrometallurgy process for the recovery and reuse of metals from spent lithium-ion batteries, using organic acid
  103. Production of nickel-rich LiNi0.89Co0.08Al0.03O2 cathode material for high capacity NCA/graphite secondary battery fabrication
  104. Special Issue: Sustainable Materials Production and Processes
  105. Corrosion polarization and passivation behavior of selected stainless steel alloys and Ti6Al4V titanium in elevated temperature acid-chloride electrolytes
  106. Special Issue: Modern Scientific Problems in Civil Engineering - Part II
  107. The modelling of railway subgrade strengthening foundation on weak soils
  108. Special Issue: Automation in Finland 2021 - Part II
  109. Manufacturing operations as services by robots with skills
  110. Foundations and case studies on the scalable intelligence in AIoT domains
  111. Safety risk sources of autonomous mobile machines
  112. Special Issue: 49th KKBN - Part I
  113. Residual magnetic field as a source of information about steel wire rope technical condition
  114. Monitoring the boundary of an adhesive coating to a steel substrate with an ultrasonic Rayleigh wave
  115. Detection of early stage of ductile and fatigue damage presented in Inconel 718 alloy using instrumented indentation technique
  116. Identification and characterization of the grinding burns by eddy current method
  117. Special Issue: ICIMECE 2020 - Part II
  118. Selection of MR damper model suitable for SMC applied to semi-active suspension system by using similarity measures
Downloaded on 8.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/eng-2022-0363/html
Scroll to top button