Home Calibration and analysis of the potable water network in the Al-Yarmouk region employing WaterGEMS and GIS
Article Open Access

Calibration and analysis of the potable water network in the Al-Yarmouk region employing WaterGEMS and GIS

  • Abdulrahman A. Abdulsamad EMAIL logo and Khalid Adel Abdulrazzaq
Published/Copyright: June 10, 2022

Abstract

Water supply and distribution networks play an important role in our daily activities. They make a substantial contribution to public health by providing potable water for public consumption and non-potable applications such as firefighters and other purposes such as irrigation. This study used ArcMap 10.8 and WaterGEMS CONNECT Edition update 1 version to create a hydraulic network model to simulate the pipes’ network. Detailed network information, including pipe lengths, layouts, and diameters, was given by the Baghdad Water Department. The TUF-2000H Handheld digital ultrasonic flow meter has been used to measure the water flows in the network’s source nodes. In eight junctions, the model was calibrated by measuring the pressures using the Bourdon gauge at selected junctions. The analysis was based on the steady-state time at the average demand. The analysis results showed that the pressures in the network ranged from 8 to 21 m H2O with a correlation coefficient of 0.988, with a noticeable decrease in pressures in the distant pipes from the sources supplying water to the network. The velocity of the main pipes was within acceptable limits 0.5–2 m/s. While for the internal distribution network, it was noticed that there is an increase in velocity for the main pipes due to low consumption in the lateral pipes.

1 Introduction

Drinking safe and drinkable water is a prerequisite for living [1]. The most critical responsibility of every municipality is to ensure that its residents have access to clean drinking water [2]. The primary purpose of the water distribution system is to provide water to every home and public place. Each home must be provided with adequate water supply at the required pressure [3]. A good water distribution network should be easy to maintain, deliver consistent quality and quantity of water to all consumers, and be designed and laid out economically [4,5]. Models of water supply systems are practical decision support tools that can be used to construct various management scenarios to improve the efficiency and reliability of existing networks and develop new networks. The hydraulic relative equations are used in the water distribution network (WDN) to compute the hydraulic parameters, such as flow rate, velocity, and water pressure. The results are given in diagrammatical representations, which the users may review [6,7]. The accuracy was determined through input parameters or estimated, and the model calibration and verification were carried out [8]. Hydraulic simulation software is a tool that a skilled operator may use to analyze drinking water distribution networks [9]. To simulate network models, several approaches have been presented. A Hardy cross method with an advantage for the computing flow in complicated networks was used [10]. These papers assessed the analyzed results from modeling the hydraulic of the potable water in the al-Yarmouk water network using WaterGEMS and GIS.

WaterGEMS and GIS were used to analyze the Al-Karada WDN. The investigation considers two scenarios: daily average and peak consumption. Calibration was performed by measuring pressures and discharges in the network using a bourdon gauge and the number of population in the study area assuming 350 l/c/day. During peak demand, the network performed well with 0.04–1.19 m/s velocities and 0.28–1.85 bar pressures [11].

The water distribution system in Makurdi was analyzed using Watercad and Epanet programs. After entering the data into the network, the analysis process was done. The evaluation was based on the comparison data of the two programs. According to the results, the distribution system’s valve placement led to a weak pressure system. An insufficient pipe count in the network leads to high velocities at high node demand, leading to increased leakage and cracks in the pipes [12].

A hydraulic model was made using GIS and Epanet to simulate the Chetouane town in Algeria. GIS provides network data such as length, topographic, and so on according to the results of the analysis; the velocity in 200 of 306 pipes had a value of less than 0.5 m/s, which may lead to deposit buildup caused by settling, while 64 pipes had a velocity between 0.5 and 1.5 m/s, which is within the permissible limits, and the remaining pipes had a velocity of more than 1.5 m/s. The pressures in 115 of 296 nodes had a value greater than 6 bar [13].

Epanet and GIS programs were used to make a hydraulic model for the distribution system to Al-Hakeem Quarter at Maqil district in the Governorate of Basrah. A bourdon gauge measures the pressures at five different locations throughout the calibration procedure. Typically, parameters such as minor loss, pipe roughness, demand, and so on, were entered into the program. Trial-and-error methods are used to choose the model’s best results based on three typical statistical coefficients [root-mean-squared error (RMSE), standard error, and correlation coefficient]. The Hazen–Williams coefficient, demands, and pattern demands significantly affect the output results [14].

2 Methodology

2.1 Study area

The Al-Yarmouk region is one of the old regions established in Baghdad, Iraq, located on the Karkh side (33°17′49.6″N 44°20′19.5″E) with an area of about 4.82 km2, consisting of six subdivisions (608, 610, 612, 614, 616, 618) according to the division of the Municipality of Baghdad. The region consists of many residential houses, schools, mosques, recreational parks, the municipal council, the civil defense, and the police station. In the last few years, the area witnessed a huge population increase and unplanned cutting of houses and land. Although it is a residential area, it now contains many restaurants and entertainment places, and it has become a destination for many people. Figure 1 shows the study area.

Figure 1 
                  The AL-Yarmouk studied area.
Figure 1

The AL-Yarmouk studied area.

2.2 Data collection

The study area’s population, a general layout map of the area under study, altitudes of nodal junctions in the water distribution system derived from a topographic map, and water demand at every node in the distribution network data are all utilized in the analyses. The data were obtained from the Baghdad Municipality Department, the Ministry of Planning and the Municipality of Al-Mansour.

2.3 Description of network

The Al-Yarmouk water network was established in the last decade by French company SOBEA in 1984 and is still up to the present time. This network has not been renewed until the current time, so it is always subject to fractures due to the high pressures in the network. Also, the inner walls of the pipes consist of layers as a result of corrosion and sedimentation in the lines. The responsible authority for this network is the Municipality of Baghdad, and the pipes are water-carrying pipes. The internal network consists of pipes with a diameter of 100–200 mm; it was renewed in the years 2009–2012. It is made of ductile iron and is under the responsibility of the Municipality of Al-Mansour. The WDN in Baghdad has been divided into two main networks, the Al-Rusafa WDN, symbolized by symbol R. It is divided according to the regions on this side into R 1, R 2,…, R n . The areas on the Karkh side are symbolized by symbol K and divided according to regions K 1, K 2,…,K n . The Al-Yarmouk region is located in part K 2, while locality 618 is located in the K 6 part of the network. The water in the network is supplied from different water treatment plants. Because it is a loop network, it is not possible to limit the supply of water to a specific station, taking into account that the primary water source in the network is the Karkh water project and the Al-Qadisiya water project.

2.4 Geographic information system

Geographic information system (GIS) has emerged as a critical water resource spatial and statistical study instrument, allowing for more effective management [15]. GIS offers a consistent environment for viewing the display model and the input/output data. This ability is beneficial in the choice process in urban hydraulic systems since it allows for faster decision-making. In addition to being time-consuming and expensive, developing a GIS model and creating the information necessary for successful water services management are challenging to achieve [16]. It has become evident that it is impossible to accomplish all of the intended management objectives without linking GIS applications in water distribution systems and hydraulic simulation models. Additionally, the integration of GIS with external models improves the overall management of the efficiency of water distribution systems [17]. The network layout was achieved using a GIS, as shown in Figure 2.

Figure 2 
                  The layout of the network.
Figure 2

The layout of the network.

2.5 WaterGEMS program

Designed for water distribution systems, WaterGEMS is a hydraulic modeling program that includes enhanced interoperability, GIS model construction, optimization, and asset management features. WaterGEMS is an easy-to-use environment for engineers to study, design, and optimize water distribution systems. Assessments of fire flow, constituent concentration and power consumption, and total cost management can all benefit from its utilization. In addition to enhanced interoperability, GIS model building, optimization, and asset management features, WaterGEMS is a multi-platform hydraulic and water quality modeling solution for water distribution systems. WaterGEMS is an easy-to-use environment for engineers to study, design, and optimize water distribution systems. Other data related to water systems and infrastructure may be managed using WaterGEMS [18].

2.6 Field work

The field measurements that were taken are divided into two parts. The first is measurement of pressures in the network. It was accomplished by using the bourdon gauge located within the washing chamber. Second, a TUF-2000H handheld digital ultrasonic flow meter was used for flow rate measures. The measurement was performed inside the valve chamber. The points at which field measurements were taken are shown in Figure 3. The data were obtained from fieldwork are shown in Table 1. The points taken represent the water sources entering the network.

Figure 3 
                  Locations of measuring points and tools used.
Figure 3

Locations of measuring points and tools used.

Table 1

Field data for source point

Point Flow (m3/h) Pressure [m (H2O)]
1 1,543 17.2
2 309 19.6
3 894 20.2
4 308 21.2
5 1,697 22.8

3 Calibration of the model

Models of water distribution systems can help design, manage, and analyze water distribution systems. Calibration is typically regarded as one of the essential parts of simulating water distribution systems. Therefore, it is included in this category. It is the method of producing changes to the model’s initial input data. Following this procedure, one may discover that the output of the simulated hydraulic and water quality simulations is sufficiently similar to that of observed field data [19]. In order to achieve high levels of precision, calibration is costly and time-consuming, and it is difficult to achieve with low precision. By generating a realistic set of fundamental inputs that accurately replicate the entire network and its components, the scope and complexity of calibration may be reduced to a minimal level [9]. The parameters that have been relied upon to reach high accuracy in the calibration process are pipe roughness and demands at junctions. A process of trial-and-error process has been implemented. Differentiation values for Hazen–William coefficients were determined through the calibration process ranging between 120 and 150 for the main pipes due to the age of the network being approximately 40 years, while for the internal network, a fixed value of 130 was adopted since the laid pipes are new. As for water, demand has relied on the population and the assumed consumption rate of 350 l/day for each person. The water requirement was distributed in the junctions relative to the area covered by each junction, and then, the water demands were modified in a number of junctions.

4 Results and discussion

After analyzing the entered data by WaterGEMS software and using steady-state time analysis type in the base calculation options, the results showed that the pressures in the network had a value ranging 8 m, which is located at 614 localities. It is considered the end of the network to 19 m at the beginning. The pressure data results show a significant degree of matching between the analytical data and the field data, as shown in Table 2. The two following standard statistical coefficients were used to determine the results of the tests, and Table 3 shows the results for the statistical coefficients:

  1. Root-mean-squared error.

  2. Coefficient of correlation (R).

(1) RMSE = 1 n 1 n ( y i y ) 2 ,

(2) R = 1 n ( y i y i ) ( y y ) 1 n ( y i y i ) 2 1 n ( y y ) 2 ,

where n is the number of readings, y i is the observed reading, y i is the average of the observed reading, y is the predicted reading, and y is the average of the predicted reading.

Table 2

The comparison between the analytical data and the field data

No. Node label Predicted pressure (m H2O) Observed pressure (m H2O) Error (%)
1 J-34 15 14.1 0.04
2 J-686 19 17.5 0.079
3 J-448 18 17.5 0.02
4 J-660 15 13.8 0.08
5 J-570 19 17.4 0.084
6 J-587 8 6.8 0.15
7 J-31 18 17.3 0.038
8 J-676 9 8.1 0.1
Table 3

Statically coefficients

No. of junctions RMSE R 2
8 1.12 0.988

The results of the velocity analysis at the main pipes consisting of 47 pipes showed that the velocity ranged from 2.83 to 0.13 m/s with an average rate of 1.14 m/s and a standard deviation of 0.62 m/s, which refers to that about 83% of velocity is more than 0.5 m/s (Figure 4).

Figure 4 
               velocity distribution in the main pipes.
Figure 4

velocity distribution in the main pipes.

As for the internal distribution network consisting of 732 pipes, the velocities in the pipes range from 0.01 to 1.68 m/s at a rate of 0.32 m/s with a standard deviation of 0.31 m/s. The overall analysis shows that the Al-Yarmouk WDN works correctly in the main pipelines, except for 614 subdivisions where the velocities and pressures are low compared to the rest of the network. The direction of flow in pipes is shown in Figure 5.

Figure 5 
               Results output example for the al-Yarmouk water network distribution.
Figure 5

Results output example for the al-Yarmouk water network distribution.

5 Conclusion

Al-Yarmouk water network’s hydraulic analysis and modeling were conducted in this study, and the following was found, as a consequence of this analysis:

  1. It is safe to say that the main pipes of the network are working well when using steady-state time analysis during the research period in the winter season.

  2. All of the resulting pressures at all junctions are sufficient for supplying water to the consumer.

  3. At times of high demand, water pressures will be low at the source of the supply, resulting in users depending on their home pumps to boost water levels, which leads to damage to the pipes network.

  4. The results indicate that coupling GIS and WaterGEMS allows the network to have a management system that can investigate problems, respond to incidents, and evaluate network operations.

  5. Multiple scenarios may simulate the network under various situations to make network administration more manageable.

  1. Funding information: The authors state no funding involved.

  2. Author contributions: All authors have accepted responsibility for the entire content of this manuscript and approved its submission.

  3. Conflict of interest: The authors state that there is no conflict of interest.

References

[1] Roy PK, Banerjee G, Mazumdar A. Development and hydraulic analysis of a proposed drinking water distribution network using WaterGEMS and GIS. Pollut Res West Bengal, India. 2015;34(2):371–9.Search in Google Scholar

[2] Swamee PK, Sharma AK. Design of water supply pipe networks. Hoboken, New Jersey: John Wiley and Sons Inc; 2008.10.1002/9780470225059Search in Google Scholar

[3] Al-hashim PMAI, Al-mansori NJ. Analysis and evaluation of the potable water network and water quality in Al-Diwaniya city. Diyala J Eng Sci. 2012;5(1):191–204.10.24237/djes.2012.05116Search in Google Scholar

[4] Garg SK, Rajeswari G. Water supply engineering. New Delhi: Khanna Publishers; 2010.Search in Google Scholar

[5] Heavens JW, Gumbel JE. To dig or not to dig: design, specification and selection issues in the trench less renovation of water mains. In: Hughes DM, editor. Assessing the future of water utility Infrastructure Management. Denver, CO, USA: AWWA; 2002.Search in Google Scholar

[6] Kapelan ZS, Savic DA, Walters GA. Multiobjective design of water distribution systems under uncertainty. Water Resour Res. 2005;41:1–15.10.1029/2004WR003787Search in Google Scholar

[7] Romano M, Kapelan Z, Savic DA. Automated detection of pipe bursts and other events in water distribution systems. J Water Resour Plan Manage. 2012;140:457–67.10.1061/(ASCE)WR.1943-5452.0000339Search in Google Scholar

[8] Kara S, Ethem Karadirek I, Muhammetoglu A, Muhammetoglu H. Hydraulic modeling of a water distribution network in a tourism area with highly varying characteristics. Proc Eng. 2016;162(November):521–9.10.1016/j.proeng.2016.11.096Search in Google Scholar

[9] Al Aboodi AH, Abbas SA, Dawood AS. Hydraulic network model of water distribution system in Al Hakeem Quarter, Maqil District, Basrah, South of Iraq. Int J Sci Eng Res. 2014;5(10):570–4.Search in Google Scholar

[10] Cross H. Analysis of flow in networks of conduits or conductors. Vol. 286. Urbana, IL: University of Illinois Engineering Experiment Station Bulletin, 1936.Search in Google Scholar

[11] Kadhim NR, Abdulrazzaq KA, Mohammed AH. Hydraulic analysis and modelling of water distribution network using WATERCAD and GIS: AL-Karada area. 2021;04004:1–8.10.1051/e3sconf/202131804004Search in Google Scholar

[12] Agunwamba JC, Ekwule OR, Nnaji CC. Performance evaluation of a municipal water distribution system using WaterCAD and Epanet. J Water Sanitation Hyg Dev. 2018;8(3):459–67.10.2166/washdev.2018.262Search in Google Scholar

[13] Abdelbaki C, Benchaib MM, Benziada S, Mahmoudi H, Goosen M. Management of a water distribution network by coupling GIS and hydraulic modeling: a case study of Chetouane in Algeria. Appl Water Sci. 2016;7:1561–7.10.1007/s13201-016-0416-1Search in Google Scholar

[14] Jonkergouw PM, Khu S-T, Kapelan ZS, Savić DA. Water quality model calibration under unknown demands. J Water Resour Plan Manag. 2008;134(4):326–36.10.1061/(ASCE)0733-9496(2008)134:4(326)Search in Google Scholar

[15] Udovyk O. GIS for intergrated water resources management. In: Hlavinek P, Kukharchyk T, Marsalek J, Mahrikova I, editors. Integrated urban water resources management. The Netherlands: Springer; 2006. p. 35–42.10.1007/1-4020-4685-5_4Search in Google Scholar

[16] Abdelbaki C, Benchaib MM, Benziada S, Mahmoudi H, Goosen M. Management of a water distribution network by coupling GIS and hydraulic modeling: a case study of Chetouane in Algeria. Appl Water Sci. 2017;7(3):1561–7.10.1007/s13201-016-0416-1Search in Google Scholar

[17] Vairavamoorthy K, Yan J, Galgale HM, Gorantiwar SD. IRA-WDS: a GIS-based risk analysis tool for water distribution systems. Env Model Softw. 2007;22:951–65.10.1016/j.envsoft.2006.05.027Search in Google Scholar

[18] Mehta D, Yadav V, Prajapati K, Waikhom S. Design of optimal water distribution systems using WaterGEMS: a case study of Surat city. In: Ghani AA, editor. Proceedings of the 37th IAHR World Congress; 2017 Aug 14-18; Kuala Lumpur, Malaysia. IAHR & USAINS HOLDING SDN BHD.Search in Google Scholar

[19] Walski TM, Chase DV, Savic DA, Grayman W, Beckwith S, Koelle E. Advanced water distribution modeling and management. Waterbury, CT: Haestad Press; 2003.Search in Google Scholar

Received: 2022-03-14
Revised: 2022-04-08
Accepted: 2022-04-12
Published Online: 2022-06-10

© 2022 Abdulrahman A. Abdulsamad and Khalid Adel Abdulrazzaq, published by De Gruyter

This work is licensed under the Creative Commons Attribution 4.0 International License.

Articles in the same Issue

  1. Research Articles
  2. Calcium carbonate nanoparticles of quail’s egg shells: Synthesis and characterizations
  3. Effect of welding consumables on shielded metal arc welded ultra high hard armour steel joints
  4. Stress-strain characteristics and service life of conventional and asphaltic underlayment track under heavy load Babaranjang trains traffic
  5. Corrigendum to: Statistical mechanics of cell decision-making: the cell migration force distribution
  6. Prediction of bearing capacity of driven piles for Basrah governatore using SPT and MATLAB
  7. Investigation on microstructural features and tensile shear fracture properties of resistance spot welded advanced high strength dual phase steel sheets in lap joint configuration for automotive frame applications
  8. Experimental and numerical investigation of drop weight impact of aramid and UHMWPE reinforced epoxy
  9. An experimental study and finite element analysis of the parametric of circular honeycomb core
  10. The study of the particle size effect on the physical properties of TiO2/cellulose acetate composite films
  11. Hybrid material performance assessment for rocket propulsion
  12. Design of ER damper for recoil length minimization: A case study on gun recoil system
  13. Forecasting technical performance and cost estimation of designed rim wheels based on variations of geometrical parameters
  14. Enhancing the machinability of SKD61 die steel in power-mixed EDM process with TGRA-based multi criteria decision making
  15. Effect of boron carbide reinforcement on properties of stainless-steel metal matrix composite for nuclear applications
  16. Energy absorption behaviors of designed metallic square tubes under axial loading: Experiment-based benchmarking and finite element calculation
  17. Synthesis and study of magnesium complexes derived from polyacrylate and polyvinyl alcohol and their applications as superabsorbent polymers
  18. Artificial neural network for predicting the mechanical performance of additive manufacturing thermoset carbon fiber composite materials
  19. Shock and impact reliability of electronic assemblies with perimeter vs full array layouts: A numerical comparative study
  20. Influences of pre-bending load and corrosion degree of reinforcement on the loading capacity of concrete beams
  21. Assessment of ballistic impact damage on aluminum and magnesium alloys against high velocity bullets by dynamic FE simulations
  22. On the applicability of Cu–17Zn–7Al–0.3Ni shape memory alloy particles as reinforcement in aluminium-based composites: Structural and mechanical behaviour considerations
  23. Mechanical properties of laminated bamboo composite as a sustainable green material for fishing vessel: Correlation of layer configuration in various mechanical tests
  24. Singularities at interface corners of piezoelectric-brass unimorphs
  25. Evaluation of the wettability of prepared anti-wetting nanocoating on different construction surfaces
  26. Review Article
  27. An overview of cold spray coating in additive manufacturing, component repairing and other engineering applications
  28. Special Issue: Sustainability and Development in Civil Engineering - Part I
  29. Risk assessment process for the Iraqi petroleum sector
  30. Evaluation of a fire safety risk prediction model for an existing building
  31. The slenderness ratio effect on the response of closed-end pipe piles in liquefied and non-liquefied soil layers under coupled static-seismic loading
  32. Experimental and numerical study of the bulb's location effect on the behavior of under-reamed pile in expansive soil
  33. Procurement challenges analysis of Iraqi construction projects
  34. Deformability of non-prismatic prestressed concrete beams with multiple openings of different configurations
  35. Response of composite steel-concrete cellular beams of different concrete deck types under harmonic loads
  36. The effect of using different fibres on the impact-resistance of slurry infiltrated fibrous concrete (SIFCON)
  37. Effect of microbial-induced calcite precipitation (MICP) on the strength of soil contaminated with lead nitrate
  38. The effect of using polyolefin fiber on some properties of slurry-infiltrated fibrous concrete
  39. Typical strength of asphalt mixtures compacted by gyratory compactor
  40. Modeling and simulation sedimentation process using finite difference method
  41. Residual strength and strengthening capacity of reinforced concrete columns subjected to fire exposure by numerical analysis
  42. Effect of magnetization of saline irrigation water of Almasab Alam on some physical properties of soil
  43. Behavior of reactive powder concrete containing recycled glass powder reinforced by steel fiber
  44. Reducing settlement of soft clay using different grouting materials
  45. Sustainability in the design of liquefied petroleum gas systems used in buildings
  46. Utilization of serial tendering to reduce the value project
  47. Time and finance optimization model for multiple construction projects using genetic algorithm
  48. Identification of the main causes of risks in engineering procurement construction projects
  49. Identifying the selection criteria of design consultant for Iraqi construction projects
  50. Calibration and analysis of the potable water network in the Al-Yarmouk region employing WaterGEMS and GIS
  51. Enhancing gypseous soil behavior using casein from milk wastes
  52. Structural behavior of tree-like steel columns subjected to combined axial and lateral loads
  53. Prospect of using geotextile reinforcement within flexible pavement layers to reduce the effects of rutting in the middle and southern parts of Iraq
  54. Ultimate bearing capacity of eccentrically loaded square footing over geogrid-reinforced cohesive soil
  55. Influence of water-absorbent polymer balls on the structural performance of reinforced concrete beam: An experimental investigation
  56. A spherical fuzzy AHP model for contractor assessment during project life cycle
  57. Performance of reinforced concrete non-prismatic beams having multiple openings configurations
  58. Finite element analysis of the soil and foundations of the Al-Kufa Mosque
  59. Flexural behavior of concrete beams with horizontal and vertical openings reinforced by glass-fiber-reinforced polymer (GFRP) bars
  60. Studying the effect of shear stud distribution on the behavior of steel–reactive powder concrete composite beams using ABAQUS software
  61. The behavior of piled rafts in soft clay: Numerical investigation
  62. The impact of evaluation and qualification criteria on Iraqi electromechanical power plants in construction contracts
  63. Performance of concrete thrust block at several burial conditions under the influence of thrust forces generated in the water distribution networks
  64. Geotechnical characterization of sustainable geopolymer improved soil
  65. Effect of the covariance matrix type on the CPT based soil stratification utilizing the Gaussian mixture model
  66. Impact of eccentricity and depth-to-breadth ratio on the behavior of skirt foundation rested on dry gypseous soil
  67. Concrete strength development by using magnetized water in normal and self-compacted concrete
  68. The effect of dosage nanosilica and the particle size of porcelanite aggregate concrete on mechanical and microstructure properties
  69. Comparison of time extension provisions between the Joint Contracts Tribunal and Iraqi Standard Bidding Document
  70. Numerical modeling of single closed and open-ended pipe pile embedded in dry soil layers under coupled static and dynamic loadings
  71. Mechanical properties of sustainable reactive powder concrete made with low cement content and high amount of fly ash and silica fume
  72. Deformation of unsaturated collapsible soils under suction control
  73. Mitigation of collapse characteristics of gypseous soils by activated carbon, sodium metasilicate, and cement dust: An experimental study
  74. Behavior of group piles under combined loadings after improvement of liquefiable soil with nanomaterials
  75. Using papyrus fiber ash as a sustainable filler modifier in preparing low moisture sensitivity HMA mixtures
  76. Study of some properties of colored geopolymer concrete consisting of slag
  77. GIS implementation and statistical analysis for significant characteristics of Kirkuk soil
  78. Improving the flexural behavior of RC beams strengthening by near-surface mounting
  79. The effect of materials and curing system on the behavior of self-compacting geopolymer concrete
  80. The temporal rhythm of scenes and the safety in educational space
  81. Numerical simulation to the effect of applying rationing system on the stability of the Earth canal: Birmana canal in Iraq as a case study
  82. Assessing the vibration response of foundation embedment in gypseous soil
  83. Analysis of concrete beams reinforced by GFRP bars with varying parameters
  84. One dimensional normal consolidation line equation
Downloaded on 5.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/jmbm-2022-0038/html
Scroll to top button