Home Modeling Human Pupil Dilation to Decouple the Pupillary Light Reflex
Article Open Access

Modeling Human Pupil Dilation to Decouple the Pupillary Light Reflex

  • Piotr Napieralski EMAIL logo and Filip Rynkiewicz
Published/Copyright: September 17, 2019

Abstract

The aim of this paper is to present methods to calculate pupil size based on various parameters, such as: luminance, age, corneal flux density or monocular/binocular effect. These models allow to distinguish pupil dilation caused by the influence of light and other factors such as psychological state of participants.The developed methods were presented based on empirical data. Various researchers estimate their equations based on oculographic data obtained in the course of experiments. The presented plots are based on those equations. Different approaches can be compared to show the difference between particular models.The methods presented in this paper enable a more detailed investigation of the influence of various parameters on the pupil. It can be used to better estimate the influence of light on pupil size. The main changes occurring in pupil size, i.e. contractions and dilation, are caused by light. Other criteria such emotional arousal, cognitive processes or even memory operations can also alter the pupil, among which the decoupling of light is important. The presented approach is distinct from other similar studies because it decouples the pupillary light reflex.

1 Introduction

The human eye is a complex biological structure, sensitive to light and pressure. Thanks to its structure, this organ provides one of the most important senses for humans, which is vision. For million years of evolution, the mammal eye has been able to differentiate between about 10 million colors and it is possibly capable of detecting a single photon. For the purpose of this research, the anatomy of the eye human has been simplified (see Figure 1).

Figure 1 Anatomy of human eye https://goo.gl/k5qap4
Figure 1

Anatomy of human eye https://goo.gl/k5qap4

Light passes through the cornea, the pupil and the lens to finally fall on the light-sensitive cells of the retina. When the amount of light coming through the iris exceeds the normal requisition, or there is a shortage of light for the eye to achieve normal vision, the iris sphincter muscleand iris dilator muscle react, creating what is known as the pupillary light reflex. The first muscle constricts the pupil when light is too bright, while the other expands it in poor light conditions. In a heightened sympathetic activity, these muscles can follow the same response pattern as in the case of various light conditions. The varying size of the pupil is a physiological response to many external factors (the pupillary response). The change in pupil size can be prompted by an involuntary reflex reaction to light (exposure to light) [1]. An increase in the size of the pupil of the eye has been found to accompany interest understood in the context of attention, and even sexual arousal [2, 3]. Other factors are memory operations [4] or a cognitive effort to distinguish between automated and controlled cognitive processing [5, 6] In normal light conditions, the pupil the pupil diameter is around 3.09mm, and 4.93mm for darkness [7]. In Figure 2, the effect of bright light and dim light is presented. As far as the latency of the light reflex, the shortest one was recorded in [8] and it was 220 ms. Some algorithms aiming to create a virtual pupil [14] can be found in the literature,which can be used to conduct experiments without the need for human subjects.

Figure 2 Pupil dilatation based on given light [9]
Figure 2

Pupil dilatation based on given light [9]

The pupillary light reflex is modeled as a physiologically-based non-linear delay differential equation. Subsequent pupillary measurements will be made with a different physiological index. It is observed that the pupil diameter changes each fixation cross location in the different emotional state [16]. The magnitude of the pupil is strongly correlated with visual attention and task performance [28]. The numerical accuracy of different variants of integral image computation algorithms allow for the possibility of multiple evaluations of different statistical characteristics of the image [27] to extract the differences from different parameters of the pupil size. The other solution is based on artificial neural networks [17, 18] used to predict the pupillary response and factor localization. [16] propose a model based on the fact that the pupil’s response to brightness changes is linear and they try to cover the range of pupillary behavior. They assume that the response of the pupil, at each time instant, is independent of the previous light intensity that it was exposed to. Models of pupil changes under the influence of light may allow us to separate factors related to the emotional state of the human study subject from the rate of these emotional cues. We propose to collect information about pupil dilation and then decouple the pupillary light reflex from this data. It is important to know the behavior of the eye due to changes in the light environment. Currently, studies on emotional states based on pupil size are performed in isolated laboratory environments. Accordingly, knowing and modeling pupil changes based on light conditions will allow us to isolate these changes. To ensure the most accurate simulation of pupil behavior, we implemented and the most popular mathematical models of the pupillary light reflex

2 Pupillary light reflex in equilibrium state

The pupillary light reflex is the main mechanism that regulates the pupillary diameter.Most models so far have been developed against the background of empirical research. Data gathered in those experiment was obtained after the pupil reached the equilibrium state, when the pupil stabilized for each illumination level. Those models are not suitable for describing dynamic changes of the pupil, but are used as a base for some models of dynamic changes of the pupil. The literature describes several dynamic behavior models built around experiments designed to measure the values of some parameters as a function of incident light intensity [10], described in Dynamic model of pupillary light reflex section. Calculation of pupil size in am equilibrium state based on given illumination can be performed using multiple formulas, which are presented at below. Based on [15], the entire equation was transformed to use nit(cd/m−2) as the main unit of luminance.

The first study was aimed at extrapolating pupil size based on given luminance was conducted by Holladay [11]. Data was collected for 3 participants of unknown age and binocular viewing.

(1) D H ( L ) = 7 exp ( 0.1007 L 0.4 )
(2) D C ( L ) = 5 tanh [ 0.61151 + 0.447 log L ]

Equation 1 plotted at Figure 3 fails for high luminance beyond ≈ 600cd/m−2 for 2mm asymptote. As in the previous study, a study by Crawford [12] also fails to reveal the age of its subjects, but their adapting field diameter is 55. In this examination, the author took samples from 10 people. It can be observed that the asymptote of 2mm given in Holladay is not present (see Figure 4). Moon and Spencer [19],

Figure 3 Pupil size for Equation 1 of Holladay
Figure 3

Pupil size for Equation 1 of Holladay

Figure 4 Pupil size for Equation 2 of Crawford
Figure 4

Pupil size for Equation 2 of Crawford

based on the equation and data approximation provided by Crawford, Blanchard [25] and Reeves [26], developed a slightly different formula, plotted in Figure 5.

Figure 5 Pupil size for Equation 3 of Moon and Spencer
Figure 5

Pupil size for Equation 3 of Moon and Spencer

(3) D M S ( L ) = 4.9 3 tanh [ 0.4 log L ]

De Groot and Gebhard [20] formulated an equation based on the averaged data from previous work, taking into consideration the number of people examined in the experiment. As can be seen in Figure 6, the asymptote of 2mm is not present in this formula either.According to the authors, it is not necessarily demanded by the data of the physiological restrictions.

Figure 6 Pupil size for Equation 4 of De Groot and Gebhard
Figure 6

Pupil size for Equation 4 of De Groot and Gebhard

Figure 7 Pupil size for Equation 5 of Stanley and Davies. Field diameter 0.4∘(first line) and 25.4∘(second line)
Figure 7

Pupil size for Equation 5 of Stanley and Davies. Field diameter 0.4(first line) and 25.4(second line)

Figure 8 Pupil size for Equation 6 Barten plotted against Stanley and Davies
Figure 8

Pupil size for Equation 6 Barten plotted against Stanley and Davies

Figure 9 Pupil size for Equation 7 Blackie and Howland
Figure 9

Pupil size for Equation 7 Blackie and Howland

(4) D D G ( L ) = 7.175 exp [ 0.00092 ( 7.597 + log L ) 3 ]

Important changes in the formulas were introduced by Stanley and Davies [13]. In contrast to previous work which assumed that dilatation depend only on a given luminance, they went on to conclude, based on Crawford, that the pupil diameter is directly correlated with the product of luminance L and the adapting field size, expressed

by a in deq2,which gives corneal flux density(cdm−2deq2). To arrive at this formula, data was gathered from 6 volunteers whose adapting field size ranged from 0.4 to 25.4. These two values were plotted at Figure 7 and used as thresholds for this experiment.

(5) D S D ( L , a ) = 7.75 5.759 ( L a / 846 ) 0.41 ( L a / 846 ) 0.41 + 2

Barten [21] developed his own formula based on Moon and Spencer and Stanley Davies consideration of field size.

(6) D S D ( L , a ) = 5 3 tanh ( 0.4 log L a 40 2 )

Blackie and Howland [22], based on a big project of modeling the emmetropization experiment, designed a formula expressed by:

(7) D B H ( L ) = 5.697 0.658 log L 0.07 ( log L ) 2

[23] Winn carried out an experiment for 91 subjects aged from 17 to 83, including students, staff and the clinical population of Aston University. Subjects maintained a steady fixation at the center of an evenly illuminated circular field with a 10 diameter. Pupil diameter was measured at five luminance levels (9, 44, 220, 1100, and 4400 cdm−2). The mean pupil size of 91 subjects was plotted as a function of age for five different levels of luminance. Thanks to this data, the slope and intercept were estimated. These values are given in Table 1.

Table 1

Estimated slopes and intercept for Winn etc

cd m−2 slope intercept r2
9 -0.043 8.046 0.0557
44 -0.04 7.413 0.0486
220 -0.032 6.275 0.377
1100 -0.02 4.854 0.0226
4400 -0.015 4.07 0.214

Luminance was restricted to illumination in Winn et al.’s experiment. To use values from Table 1 in pupil prediction equation, the slope needs to be presented as a function of log luminance with a cubic polynomial (see Equation 8). The same pattern was followed in the case of the intercept (see Equation 9).

(8) W s ( L ) = k = 0 3 S K log min 4400 , max 9 , L k s 0 = 0.24501 s 1 = 0.0368073 s 2 = 0.210892 s 3 = 0.00281557
(9) W I ( L ) = k = 0 3 b K log min 4400 , max 9 , L k b 0 = 6.9039 b 1 = 2.7765 b 2 = 1.909 b 3 = 0.25599

hen, to estimate the data of Winn et al., both functions were combined:

(10) D W ( L , y ) = W S ( L ) y + W I ( L )

where y denotes the age of a participant.

Wattson and Yellot [15] created unified formula, which combines the previously described equation as well as considering new parameters.

Taking into account previously conducted experiments in which only the dilatation of one eye was measured where the result differs from the experiments with

Figure 10 Pupil size for Equation 10 off Winn.
Figure 10

Pupil size for Equation 10 off Winn.

both, given in the same adapting light (as in the Figure 11), the monocular effect was created. Based on a comparison of mono and binocular data the conclusion was that the modeling of the monocular effect can be superimposed by a horizontal shift on a log axis. In which the average optimal shift of monocular data to match binocular data amounted to 0.1015. With this information, a the factor of 0.1 can be used to shift data when in an experiment only one eye is examined, and 1 when the data is collected on the binocular (Equation 11)

Figure 11 Binocular and monocular data from Doesschate and Alpem [24]
Figure 11

Binocular and monocular data from Doesschate and Alpem [24]

(11) M ( 1 ) = 0.1
(12) M ( 2 ) = 1

In addition to using the monocular effect, the effective corneal flux density formula was also developed, which extends the previous corneal flux density by:

(13) F = L a M ( e )

The result is the product of luminance, adapting area and monocular effect.

In Winn et al. the age of participant was given as a crucial parameter in pupil size approximation, although data was limited to 4400 cdm2 and the adapting field size of 10. Assuming a linear relation between the slope function from Winnet al. and the pupil diameter calculated in Stanley Davies for the same luminance, the new general slope function could be designed.

(14) S ( L , a , e ) = 0.02132 0.0095623 D S D ( L M ( e ) , a )

The rate of change of the pupil diameter with age was estimated based on the function of luminance, area flux density, age, referenced age and eye function.

(15) A ( L , a , y , y 0 , e ) = ( y y 0 ) S ( L , a , e ) , 20 y 83

Age must be in the range of that of the subjects in Winn et al. Reference age is the age of observers in the experiment. As far as reference age in the equation of Wattson Yellot, it is equal to 28.58, which is the average age of the subjects in the Stanley Davies study.

Figure 12 and 13 show all the described methods and they demonstrate that these methods can differ depending on the parameters. Figure 12 presents monocular e=2 data from a small adapting area a=10. It can be seen that the Unified formula, based on Stanley and Davies, gives similar results to the Barten formula. Meanwhile In Figure 13, it can be observed that the Unified, Barten, Stanley Davies and Moon-Spencer formulas give similar results, which shows that the Watson and Yellot model can be used to predict pupil size more precisely than previous models

Figure 12 Pupil size for Equation 15 of Watson and Yellot, compared to all previous models. a=10°, monocular.
Figure 12

Pupil size for Equation 15 of Watson and Yellot, compared to all previous models. a=10°, monocular.

Figure 13 Pupil size for Equation 15 of Watson and Yellot, compared to all previous models. a=60°, binocular.
Figure 13

Pupil size for Equation 15 of Watson and Yellot, compared to all previous models. a=60°, binocular.

3 Dynamic model of pupillary light reflex

As described in previous chapter, models only give information about pupil size after adaptation to a given light luminosity. Meaning that it does not describe changes of the pupil in a time interval. This poses a significant problem in research which includes constant changes of light or in monitoring the changes on psychological impulses. Models of such changes need to take into consideration the specific physiological behavior of the pupil. In the case of PLR, iridial reaction is caused by light striking through the retina. This action sends a neural signal, but it needs time to cause the iridial reaction, which is why it is modelled by a time delayed equation. Another parameter that affects the pupil change is the threshold value of light flux. Luminosity higher than that given threshold will not cause the pupil to react. As the final visual effect of PLR is the movement of dilator and sphincter muscles, there are PLR models that are designed to simulate behavior of those muscles based on autonomic nervous system input. In [29] the model is targeted to simulate only short light flashes, which does not cover all possible cases of PLR behavior. The model presented at [30] is over complicated with multiple second-order delay differential equations, and thus it is impractical for designing a robust inverse algorithm to obtain model parameters from experimental data. The model used in this experiment is based on the Moon and Spencer (Equation 3), for equilibrium pupil state, and Longtin and Milton’s time dependent pupil size which is described by a time delayed equation. The Equation 16 describes the behavior of dynamic changes of the pupil in response to light where the pupillary latency – the time delay between the instant in which the light pulse reaches the retina and the beginning of iridial reaction – is given by τ and time t. Parameter D describes the pupil diameter in millimeters, which is the output of the solved equation. This model is able to describe changes of the individual pupil in specific light conditions. Despite the fact that Pamplona is based on Moon and Spencer’s function and not the newest Wattson and Yellot, the literature shows that this method gives very high correlation with real life scenarios.

(16) d M d D d D d t + 2.3026 atanh D 4.9 3 = 5.2 0.45 ln ϕ ( t τ ) ϕ ¯

4 Description of the research environment

In order to record pupil changes caused by either internal or external factors, a device called an eye-tracker can be used. The main task of this device is to track and record gaze, but in addition, vital oculography parameters can be recorded. Blink occurrence frequency, saccades detection and real time pupil size monitoring, are the most common ones. In order to record those changes multiple cameras, either InfraRed or RGB, must be used. The arrangement of those cameras can be used to distinguish two main types of eye trackers.

Head-mounted eye trackers, mostly in the shape of glasses, have multiple cameras aimed directly onto the subject’s eyes, and one so-called global camera to record the scene in front of the subject. The greatest advantage of these devices is their mobility, which allows the subject to move their head freely and change locations. The biggest disadvantage is that they have lower precision and accuracy compared with stationary ones, because of the subject’s head movement.

The second type of eye-trackers are so-called remoteeye trackers. This is a nonintrusive peripheral device that has no contact with human body. Cameras that are placed inside this device are aimed in front of the scene, where the face of subject must be present. These are stationary devices with no possibility of changing its location, thus the test must take place in same area. The biggest advantage over the wearable eye tracker is that this kind of eye tracker is nonintrusive, which is more suitable to study psychological reflexes. Thus, the device is calibrated in a way that has a certain window where the eye of the subject must be visible and there is no head movement of subject. Accuracy is higher in comparison with a wearable one.

Taking into consideration that experiment is aimed at real life scenarios like shopping, walking in the street, or sport event activity, the most important property of the device must be its mobility. Based on other research and solutions available on the market, the wearable eye tracker was chosen for this experiment. The second attribute of the device must be the possibility to develop and implement new algorithms for measuring pupil changes over time. There are multiple DYI wearable eye-trackers, but they lack precision and accuracy in comparison to devices provided by commercial solutions. Based on devices available for our use, the Tobii Pro Glasses 2, and Pupil Lab, both were tested in accuracy and precision. The conclusion of the preliminary conducted experiment was that the Tobii Pro Glasses 2 have slightly better results than the other device. However, the lack of possibility to extend usage of Tobii by adding new algorithms or another peripheral device resulted in the Pupil Lab being chosen as the best choice.

This device is capable of gaze estimation with 0.6 degree of visual angle (0.08 degree precision) with a processing pipeline latency of only 0.045 seconds, blink detection, pupil size monitoring and more. The glasses-like headset eye tracker, presented at Figure 14a, consists of two RGB cameras with an IR filter and one global directed RGB camera at the front of the user. The frontal camera is able to capture an image at a max resolution of 1920x1080 pixels at 30Hz with a 90-degree diagonal field of view. Two IR cameras, which can operate up to 200Hz, are located at glasses frames and aimed directly at the eyes of the subject. Software used in Pupil Lab uses the “dark pupil” detection method,presented at Figure 15, thus, IR cameras must be able to capture video at a specific range of the IR spectrum, in this device it is a 860nm wavelength. Each image captured by the IR camera is analyzed by open source Pupil Lab software. Thanks to the flexibility and extensibility of the source code, additional sensors can be added to this eye tracker. Additionally, in the case of this research, a simple luxometer was added to eye tracker as an external sensor.

Figure 14 Pupil Lab eye tracker and BH1603FVC Rohm sensor.
Source https://bit.ly/2TH3hby https://bit.ly/2VbrV1d
Figure 14

Pupil Lab eye tracker and BH1603FVC Rohm sensor.

Source https://bit.ly/2TH3hby https://bit.ly/2VbrV1d

Figure 15 Pupil recognition algorithm in PupilLab device
Figure 15

Pupil recognition algorithm in PupilLab device

The BH1603FVC Rohm [1](Figure 14b) analog current output ambient light sensor was used to determine the amount of light cast at the pupil. It is a device with a compacted surface of 3.0 x 1.6 mm and a spectral sensitivity close to human eye sensitivity. The sensor is capable of measuring ambient light in a range of 0 - 1 000 lux on H-Gain Mode, 0 – 10 000 in M-Gain and 0 – 100 000 on L-Gain. To measure which range will be most suitable for the conducted experiment the sensor was placed with 50cm range from LED lamp. This experiment gave values from 6 000 to 9 000 lux,which remains in the H-Gain range of the sensor and in that mode the sensor was calibrated. This sensor was placed near the IR camera of the left eye, and only these eye responses are recorded during the experiment.

To recognize and measure the changes of the pupil over time, the Pupil Lab method was used, as a default for the hardware. The detection method used in the software provided by Pupil Lab consists of 7 steps, presented at Figure 15. First the image of eye is converted to grayscale.

Using a Haar-like feature, the region of interest – the estimated region where pupil can be – is calculated, and significantly cut the unwanted pixels from source image (Figure 15a). The region obtained in the previous step is filtered by a Canny edge detector (Figure 15b). For the region of interest, the histogram is calculated (Figure 15c), and the “dark” region is defined by the offset from the lowest spike in the histogram. All edges with spectral reflections and not in the “dark” region are excluded(Figure 15d). Remaining edges are filtered and split into sub contours, based on the criteria of curvature continuity (Figure 15e). Finally, the ellipse is fitted using the least square method and additional criteria like ellipse circumference (Figure 15f).

5 Experiment

In the experiment, various scenarios were tested. In each of them, the person on whom the experiment is carried out was asked to always look forward, with the freedom to move their head, without squinting eyes to ensure that both th eye-tracker and light detector will give the best results. The figures presented below show the deviation that can be treated as non-light triggered changes. Data from luxometer and eye-tracker gathered along the experiment was used to generate the artificial signal using Equation 16, plotted as solid line. The real data, points, was plotted against the generated one to find how much those two signals differ at, example at Figure 16. All not convergence is treated as pupil change caused by non-light factors, such as emotion, accommodation, etc.

Figure 16 Plot of data generated by [10] (solid line), and data gathered by PupilLab (points)
Figure 16

Plot of data generated by [10] (solid line), and data gathered by PupilLab (points)

6 Comparison of data and model

To compare data gathered by device and data calculated by Pamplona (Equation 16) the difference in pupil size have been calculated. For experiment presented at Figure 16a the difference was plotted at Figure 17a where the mean difference in distance is −0.215916mm. For second experiment presented at Figure 16b the difference was plotted at Figure 17b where the mean difference in distance is 0.041678mm. For third experiment presented at Figure 16c the difference was plotted at Figure 17c where the mean difference in distance is −0.278634mm.

Figure 17 Plot of difference between pupil size gathered by device and calculated by Equation 16
Figure 17

Plot of difference between pupil size gathered by device and calculated by Equation 16

That information shows how much prediction from Pamplona differ from data gathered by device. Those values can give information how much change in pupil size was cause by specific type of stimulus, either internal or external one.

7 Conclusion

Based on the existing models, the method for measuring a light-adapted pupil diameter was implemented for pupil in equilibrium and dynamic case. The solution to predict pupil size changes under visible light stimuli was presented in this article. The change in pupil size under the influence of light has been modeled and tested against the existing popular models and real life data. Those data has been gathered using constructed device that consist of eye-tracker and additional ambient light sensor. This device has gave the opportunity to verify implemented methods and to find light and non-light factors that can affect human pupillary light reflex. Conducted experiment have shown the lack of possibility to distinguish, analyze and classify the root cause of each change in size of the pupil.

8 Future work

Next conducted experiments will be focused on finding and classifying the causes of each deviation in scenarios which the light can change its intensity. Additional diagnostic methods like EEG will be use, because of the connectivity between human sympathetic nervous system and the eye.

References

[1] Saladin K., Anatomy and physiology, New York: McGraw-Hill, 2012.Search in Google Scholar

[2] Hess E., Polt J., Pupil Size as Related to Interest Value of Visual Stimuli, Science, 1960132(3423), pp.349-350.10.1126/science.132.3423.349Search in Google Scholar

[3] Hammerer D., Hopkins A., Betts M., Maaß A., Dolan R. and Düzel E., Emotional arousal and recognition memory are differentially reflected in pupil diameter responses during emotional memory for negative events in younger and older adults, Neurobiology of Aging, 2017, 58, pp.129-139.10.1016/j.neurobiolaging.2017.06.021Search in Google Scholar

[4] Bradley M., Miccoli L., Escrig M. and Lang P., The pupil as a measure of emotional arousal and autonomic activation, Psychophysiology, 2008, 45(4), pp.602-607.10.1111/j.1469-8986.2008.00654.xSearch in Google Scholar

[5] Querino E., dos Santos L., Ginani G., Nicolau E., Miranda D., Romano-Silva M. and Malloy-Diniz L., Cognitive effort and pupil dilation in controlled and automatic processes, Translational Neuroscience, 2015 6(1).10.1515/tnsci-2015-0017Search in Google Scholar

[6] Staniucha R., Wojciechowski A., Mouth features extraction for emotion classification, 2016.10.15439/2016F390Search in Google Scholar

[7] Wyatt H., The form of the human pupil, Vision Research, 1995, 35(14), pp.2021-2036.10.1016/0042-6989(94)00268-QSearch in Google Scholar

[8] Ellis C., The pupillary light reflex in normal subjects, British Journal of Ophthalmology, 1981, 65(11), pp.754-759.10.1136/bjo.65.11.754Search in Google Scholar PubMed PubMed Central

[9] Walker H., Hall W., Hurst J., Clinical methods, Boston: Butter-worths, 1990.Search in Google Scholar

[10] Pamplona V., Oliveira M., Baranoski G., Photorealistic models for pupil light reflex and iridal pattern deformation, ACM Transactions on Graphics, 2009, 28(4), pp.1-12.10.1145/1559755.1559763Search in Google Scholar

[11] Holladay L. ,The Fundamentals of Glare and Visibility, Journal of the Optical Society of America, 1926, 12(4), 271.10.1364/JOSA.12.000271Search in Google Scholar

[12] Crawford B., The Dependence of Pupil Size upon External Light Stimulus under Static and Variable Conditions, Proceedings of the Royal Society B: Biological Sciences, 1936, 121(823), pp.376-395.10.1098/rspb.1936.0072Search in Google Scholar

[13] Stanley P., Davies A., The effect of field of view size on steady-state pupil diameter, Ophthalmic and Physiological Optics, 1995, 15(6), pp.601-603.10.1046/j.1475-1313.1995.9400019v.xSearch in Google Scholar

[14] Walraven P., The virtual pupil, Journal of Modern Optics, 2009, 56(20), pp.2251-2253.10.1080/09500340903380927Search in Google Scholar

[15] Watson A., Yellott J., A unified formula for light-adapted pupil size, Journal of Vision, 2012, 12(10), pp.12-12.10.4016/40193.01Search in Google Scholar

[16] Raiturkar P., Kleinsmith A., Keil A., Banerjee A., Jain E., Decoupling light reflex from pupillary dilation to measure emotional arousal in videos, SAP ’16) ACM, New York, NY, USA, 2016, 89-96.10.1145/2931002.2931009Search in Google Scholar

[17] Garbaa H., Jackowska-Strumillo L., Grudzien K., Romanowski A., Neural network approach to ECT inverse problem solving for estimation of gravitational solids flow, 2014 Federated Conference on Computer Science and Information Systems, Warsaw, 2014, pp. 19-26. doi: 10.15439/2014F368.10.15439/2014F368Search in Google Scholar

[18] Lipinski P., Watermarking software in practical applications, Bulletin of the Polish Academy of Sciences: Technical Sciences, 2011, 59(1), 21-25.10.2478/v10175-011-0004-3Search in Google Scholar

[19] Moon P., Spencer D., The Transient Stiles-Crawford Effect, Journal of the Optical Society of America, 1944, 34(12), p.744.10.1364/JOSA.34.000744Search in Google Scholar

[20] de Groot S., Gebhard J., Pupil Size as Determined by Adapting Luminance, Journal of the Optical Society of America, 1952, 42(7), p.492.10.1364/JOSA.42.000492Search in Google Scholar

[21] Barten P., Contrast Sensitivity of the Human Eye and Its Effects on Image Quality, Bellingham: SPIE. 2000.10.1117/3.353254Search in Google Scholar

[22] Blackie C., Howland H., An extension of an accommodation and convergence model of emmetropization to include the effects of illumination intensity, Ophthalmic and Physiological Optics, 1999, 19(2), pp.112-125.10.1046/j.1475-1313.1999.00436.xSearch in Google Scholar

[23] Winn B., Whitaker D., Elliott D.B., Phillips N., Factors affecting light-adapted pupil size in normal human subjects, Investigative ophthalmology & visual science, 1994, 35 3, 1132-7.Search in Google Scholar

[24] Doesschate J., Alpern M., Effect of photoexcitation of the two retinas on pupil size, Journal of Neurophysiology, 1967, 30(3), 562–576.10.1152/jn.1967.30.3.562Search in Google Scholar PubMed

[25] Blanchard J., The Brightness Sensibility of the Retina, Physical Review, 1918, 11(2), pp.81-99.10.1103/PhysRev.11.81Search in Google Scholar

[26] Reeves P., Rate of pupillary dilation and contraction, Psychological Review, 1918, 25(4), pp.330-340.10.1037/h0075293Search in Google Scholar

[27] Puchala D., Stokfiszewski K., Numerical accuracy of integral images computation algorithms, in IET Image Processing, vol. 12, no. 1, pp. 31-41, 1 2018. doi: 10.1049/iet-ipr.2017.0161.10.1049/iet-ipr.2017.0161Search in Google Scholar

[28] Ebitz R., Pearson J., Platt M., Pupil size and social vigilance in rhesus macaques. Frontiers in Neuroscience, 8. Computation Algorithms, IET Image Processing, 2014, vol. 12, no. 1, pp. 31-41.10.3389/fnins.2014.00100Search in Google Scholar PubMed PubMed Central

[29] Fan X., Yao G., Modeling Transient Pupillary Light Reflex Induced by a Short Light Flash, IEEE Transactions on Biomedical Engineering, 2011, 58, 36-42.10.1109/TBME.2010.2080678Search in Google Scholar PubMed PubMed Central

[30] Suaste-Gómez E., Reyes Cruz H., Inverse dynamic model of the pupil muscle plant in the simulation of response to sound, stimuli and hippus, WIT Transactions on Biomedicine and Health. 2011, 15. 407-414. 10.2495/EHR110351.10.2495/EHR110351Search in Google Scholar

[31] Morelli M. S., Giannoni A., Passino C., Landini L., Emdin M., Vanello N., A Cross-Correlational Analysis between Electroencephalographic and End-Tidal Carbon Dioxide Signals: Methodological Issues in the Presence of Missing Data and Real Data Results, Sensors (Basel, Switzerland), 2016, 16(11), 1828. doi:10.3390/s16111828.10.3390/s16111828Search in Google Scholar PubMed PubMed Central

Received: 2019-06-21
Accepted: 2019-07-02
Published Online: 2019-09-17

© 2019 P. Napieralski and F. Rynkiewicz, published by De Gruyter

This work is licensed under the Creative Commons Attribution 4.0 International License.

Articles in the same Issue

  1. Regular Articles
  2. Non-equilibrium Phase Transitions in 2D Small-World Networks: Competing Dynamics
  3. Harmonic waves solution in dual-phase-lag magneto-thermoelasticity
  4. Multiplicative topological indices of honeycomb derived networks
  5. Zagreb Polynomials and redefined Zagreb indices of nanostar dendrimers
  6. Solar concentrators manufacture and automation
  7. Idea of multi cohesive areas - foundation, current status and perspective
  8. Derivation method of numerous dynamics in the Special Theory of Relativity
  9. An application of Nwogu’s Boussinesq model to analyze the head-on collision process between hydroelastic solitary waves
  10. Competing Risks Model with Partially Step-Stress Accelerate Life Tests in Analyses Lifetime Chen Data under Type-II Censoring Scheme
  11. Group velocity mismatch at ultrashort electromagnetic pulse propagation in nonlinear metamaterials
  12. Investigating the impact of dissolved natural gas on the flow characteristics of multicomponent fluid in pipelines
  13. Analysis of impact load on tubing and shock absorption during perforating
  14. Energy characteristics of a nonlinear layer at resonant frequencies of wave scattering and generation
  15. Ion charge separation with new generation of nuclear emulsion films
  16. On the influence of water on fragmentation of the amino acid L-threonine
  17. Formulation of heat conduction and thermal conductivity of metals
  18. Displacement Reliability Analysis of Submerged Multi-body Structure’s Floating Body for Connection Gaps
  19. Deposits of iron oxides in the human globus pallidus
  20. Integrability, exact solutions and nonlinear dynamics of a nonisospectral integral-differential system
  21. Bounds for partition dimension of M-wheels
  22. Visual Analysis of Cylindrically Polarized Light Beams’ Focal Characteristics by Path Integral
  23. Analysis of repulsive central universal force field on solar and galactic dynamics
  24. Solitary Wave Solution of Nonlinear PDEs Arising in Mathematical Physics
  25. Understanding quantum mechanics: a review and synthesis in precise language
  26. Plane Wave Reflection in a Compressible Half Space with Initial Stress
  27. Evaluation of the realism of a full-color reflection H2 analog hologram recorded on ultra-fine-grain silver-halide material
  28. Graph cutting and its application to biological data
  29. Time fractional modified KdV-type equations: Lie symmetries, exact solutions and conservation laws
  30. Exact solutions of equal-width equation and its conservation laws
  31. MHD and Slip Effect on Two-immiscible Third Grade Fluid on Thin Film Flow over a Vertical Moving Belt
  32. Vibration Analysis of a Three-Layered FGM Cylindrical Shell Including the Effect Of Ring Support
  33. Hybrid censoring samples in assessment the lifetime performance index of Chen distributed products
  34. Study on the law of coal resistivity variation in the process of gas adsorption/desorption
  35. Mapping of Lineament Structures from Aeromagnetic and Landsat Data Over Ankpa Area of Lower Benue Trough, Nigeria
  36. Beta Generalized Exponentiated Frechet Distribution with Applications
  37. INS/gravity gradient aided navigation based on gravitation field particle filter
  38. Electrodynamics in Euclidean Space Time Geometries
  39. Dynamics and Wear Analysis of Hydraulic Turbines in Solid-liquid Two-phase Flow
  40. On Numerical Solution Of The Time Fractional Advection-Diffusion Equation Involving Atangana-Baleanu-Caputo Derivative
  41. New Complex Solutions to the Nonlinear Electrical Transmission Line Model
  42. The effects of quantum spectrum of 4 + n-dimensional water around a DNA on pure water in four dimensional universe
  43. Quantum Phase Estimation Algorithm for Finding Polynomial Roots
  44. Vibration Equation of Fractional Order Describing Viscoelasticity and Viscous Inertia
  45. The Errors Recognition and Compensation for the Numerical Control Machine Tools Based on Laser Testing Technology
  46. Evaluation and Decision Making of Organization Quality Specific Immunity Based on MGDM-IPLAO Method
  47. Key Frame Extraction of Multi-Resolution Remote Sensing Images Under Quality Constraint
  48. Influences of Contact Force towards Dressing Contiguous Sense of Linen Clothing
  49. Modeling and optimization of urban rail transit scheduling with adaptive fruit fly optimization algorithm
  50. The pseudo-limit problem existing in electromagnetic radiation transmission and its mathematical physics principle analysis
  51. Chaos synchronization of fractional–order discrete–time systems with different dimensions using two scaling matrices
  52. Stress Characteristics and Overload Failure Analysis of Cemented Sand and Gravel Dam in Naheng Reservoir
  53. A Big Data Analysis Method Based on Modified Collaborative Filtering Recommendation Algorithms
  54. Semi-supervised Classification Based Mixed Sampling for Imbalanced Data
  55. The Influence of Trading Volume, Market Trend, and Monetary Policy on Characteristics of the Chinese Stock Exchange: An Econophysics Perspective
  56. Estimation of sand water content using GPR combined time-frequency analysis in the Ordos Basin, China
  57. Special Issue Applications of Nonlinear Dynamics
  58. Discrete approximate iterative method for fuzzy investment portfolio based on transaction cost threshold constraint
  59. Multi-objective performance optimization of ORC cycle based on improved ant colony algorithm
  60. Information retrieval algorithm of industrial cluster based on vector space
  61. Parametric model updating with frequency and MAC combined objective function of port crane structure based on operational modal analysis
  62. Evacuation simulation of different flow ratios in low-density state
  63. A pointer location algorithm for computer visionbased automatic reading recognition of pointer gauges
  64. A cloud computing separation model based on information flow
  65. Optimizing model and algorithm for railway freight loading problem
  66. Denoising data acquisition algorithm for array pixelated CdZnTe nuclear detector
  67. Radiation effects of nuclear physics rays on hepatoma cells
  68. Special issue: XXVth Symposium on Electromagnetic Phenomena in Nonlinear Circuits (EPNC2018)
  69. A study on numerical integration methods for rendering atmospheric scattering phenomenon
  70. Wave propagation time optimization for geodesic distances calculation using the Heat Method
  71. Analysis of electricity generation efficiency in photovoltaic building systems made of HIT-IBC cells for multi-family residential buildings
  72. A structural quality evaluation model for three-dimensional simulations
  73. WiFi Electromagnetic Field Modelling for Indoor Localization
  74. Modeling Human Pupil Dilation to Decouple the Pupillary Light Reflex
  75. Principal Component Analysis based on data characteristics for dimensionality reduction of ECG recordings in arrhythmia classification
  76. Blinking Extraction in Eye gaze System for Stereoscopy Movies
  77. Optimization of screen-space directional occlusion algorithms
  78. Heuristic based real-time hybrid rendering with the use of rasterization and ray tracing method
  79. Review of muscle modelling methods from the point of view of motion biomechanics with particular emphasis on the shoulder
  80. The use of segmented-shifted grain-oriented sheets in magnetic circuits of small AC motors
  81. High Temperature Permanent Magnet Synchronous Machine Analysis of Thermal Field
  82. Inverse approach for concentrated winding surface permanent magnet synchronous machines noiseless design
  83. An enameled wire with a semi-conductive layer: A solution for a better distibution of the voltage stresses in motor windings
  84. High temperature machines: topologies and preliminary design
  85. Aging monitoring of electrical machines using winding high frequency equivalent circuits
  86. Design of inorganic coils for high temperature electrical machines
  87. A New Concept for Deeper Integration of Converters and Drives in Electrical Machines: Simulation and Experimental Investigations
  88. Special Issue on Energetic Materials and Processes
  89. Investigations into the mechanisms of electrohydrodynamic instability in free surface electrospinning
  90. Effect of Pressure Distribution on the Energy Dissipation of Lap Joints under Equal Pre-tension Force
  91. Research on microstructure and forming mechanism of TiC/1Cr12Ni3Mo2V composite based on laser solid forming
  92. Crystallization of Nano-TiO2 Films based on Glass Fiber Fabric Substrate and Its Impact on Catalytic Performance
  93. Effect of Adding Rare Earth Elements Er and Gd on the Corrosion Residual Strength of Magnesium Alloy
  94. Closed-die Forging Technology and Numerical Simulation of Aluminum Alloy Connecting Rod
  95. Numerical Simulation and Experimental Research on Material Parameters Solution and Shape Control of Sandwich Panels with Aluminum Honeycomb
  96. Research and Analysis of the Effect of Heat Treatment on Damping Properties of Ductile Iron
  97. Effect of austenitising heat treatment on microstructure and properties of a nitrogen bearing martensitic stainless steel
  98. Special Issue on Fundamental Physics of Thermal Transports and Energy Conversions
  99. Numerical simulation of welding distortions in large structures with a simplified engineering approach
  100. Investigation on the effect of electrode tip on formation of metal droplets and temperature profile in a vibrating electrode electroslag remelting process
  101. Effect of North Wall Materials on the Thermal Environment in Chinese Solar Greenhouse (Part A: Experimental Researches)
  102. Three-dimensional optimal design of a cooled turbine considering the coolant-requirement change
  103. Theoretical analysis of particle size re-distribution due to Ostwald ripening in the fuel cell catalyst layer
  104. Effect of phase change materials on heat dissipation of a multiple heat source system
  105. Wetting properties and performance of modified composite collectors in a membrane-based wet electrostatic precipitator
  106. Implementation of the Semi Empirical Kinetic Soot Model Within Chemistry Tabulation Framework for Efficient Emissions Predictions in Diesel Engines
  107. Comparison and analyses of two thermal performance evaluation models for a public building
  108. A Novel Evaluation Method For Particle Deposition Measurement
  109. Effect of the two-phase hybrid mode of effervescent atomizer on the atomization characteristics
  110. Erratum
  111. Integrability analysis of the partial differential equation describing the classical bond-pricing model of mathematical finance
  112. Erratum to: Energy converting layers for thin-film flexible photovoltaic structures
Downloaded on 9.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/phys-2019-0047/html
Scroll to top button