Startseite Impact of a satellite laboratory on turnaround times for the emergency department
Artikel
Lizenziert
Nicht lizenziert Erfordert eine Authentifizierung

Impact of a satellite laboratory on turnaround times for the emergency department

  • Gurdeep Dhatt , Joseph Manna , Bassam Bishawi , Diane Chetty , Ahlam Al Sheiban und David James
Veröffentlicht/Copyright: 1. Oktober 2008
Veröffentlichen auch Sie bei De Gruyter Brill

Abstract

Background: Prolonged laboratory turnaround time (TAT) contributes to prolonged length of stay in emergency departments (EDs). The TAT of laboratory test results is a common key performance indicator by which clinicians and regulatory bodies evaluate laboratory performance. Establishing satellite laboratories in EDs staffed by laboratory technologists is one approach towards reducing TAT.

Methods: TAT data were collected for three time intervals: (a) sampling time to time samples received in the laboratory (transportation time), (b) sample received in the laboratory until results were available for viewing on the laboratory information system monitor or collection by ED staff (within laboratory TAT), and (c) sampling to availability of results (total TAT, e.g., a+b). The target was to achieve a median within laboratory TAT of 45 min for samples received from the ED.

Results: The median transportation times for samples to be delivered to the central and satellite laboratory were 22 min and 1 min, respectively (p<0.0001). The median within laboratory TATs were 45 [95% confidence interval (CI) 43–49] and 34 (95% CI 33–35) min for the central and satellite laboratories, respectively (p<0.001).

Conclusions: A satellite laboratory in the ED can significantly reduce laboratory TAT.

Clin Chem Lab Med 2008;46:1464–7.


Corresponding author: Dr. G.S. Dhatt, Department of Pathology, Tawam Hospital, Al Ain, Abu Dhabi, United Arab Emirates Phone: +971-3-707-2417, Fax: +971-3-707-2418,

Received: 2008-1-17
Accepted: 2008-7-2
Published Online: 2008-10-01
Published in Print: 2008-10-01

©2008 by Walter de Gruyter Berlin New York

Artikel in diesem Heft

  1. Review
  2. Use of biochemical markers of bone turnover in the management of postmenopausal osteoporosis
  3. Minireview
  4. Is serum procalcitonin able to predict long-term kidney morbidity from urinary tract infections in children?
  5. Genetics and Molecular Diagnostics
  6. Association between the 2756A&gt; G variant in the gene encoding methionine synthase and myocardial infarction in Tunisian patients
  7. Common 894G>T single nucleotide polymorphism in the gene coding for endothelial nitric oxide synthase (eNOS) and risk of congenital heart defects
  8. New sequence variants in BRCA1 and BRCA2 genes detected by high-resolution melting analysis in an elderly healthy female population in Croatia
  9. Enzyme-free signal amplification of analyte in a single closed tube by fluorescent hybridization chain reaction
  10. Five X-chromosome short tandem repeats in a Western Mexican population
  11. General Clinical Chemistry and Laboratory Medicine
  12. Prolyl-hydroxyproline dipeptide in non-hydrolyzed morning urine and its value in postmenopausal osteoporosis
  13. Methionine metabolism in an animal model of sepsis
  14. Hypochlorous acid is a potent inactivator of human plasminogen at concentrations secreted by activated granulocytes
  15. Association of serum γ-glutamyltransferase with C-reactive protein levels and white blood cell count in Korean adults
  16. Immunoradiometric determination of thyroglobulin in serum samples by time calibration transfer
  17. Serum interleukin 6 (IL-6) and C-reactive protein (CRP) levels in colorectal adenoma and cancer patients
  18. Measurement of 10,11-dihydro-10-hydroxy-carbamazepine in serum and plasma by high-performance liquid chromatography
  19. The relationship between usual coffee consumption and serum C-reactive protein level in a Japanese female population
  20. Reference Values and Biological Variations
  21. Analytical quality goals for parathyroid hormone based on biological variation
  22. Preanalytical effects of pneumatic tube transport on routine haematology, coagulation parameters, platelet function and global coagulation
  23. Validation and Outcome Studies
  24. Automated immunoassay methods for ferritin: recovery studies to assess traceability to an international standard
  25. An expert system for the classification of serum protein electrophoresis patterns
  26. Impact of a satellite laboratory on turnaround times for the emergency department
  27. Effect of ampicillin-sulbactam on clinical capillary zone electrophoresis of serum proteins
  28. Guidelines and Recommendations
  29. Protein standardization V: value transfer. A practical protocol for the assignment of serum protein values from a Reference Material to a Target Material
  30. Letter to the Editor
  31. Biological variability evaluation and comparison of three different methods for C-peptide measurement
  32. Abstracts
  33. 10.1515/CCLM.2008.361
Heruntergeladen am 16.9.2025 von https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2008.290/html
Button zum nach oben scrollen