Preanalytical effects of pneumatic tube transport on routine haematology, coagulation parameters, platelet function and global coagulation
-
Olof Wallin
Abstract
Background: Pneumatic tube transport of blood samples reduces turnaround times and labour. However, the preanalytical effects on new clinical chemistry parameters and instruments are not fully known. The aim of this study was to evaluate the effect of pneumatic tube transport on haematology and coagulation parameters, including platelet function with PFA-100®, and global coagulation with a thromboelastograph.
Methods: Paired venous blood samples from healthy volunteers were obtained before and after 1 week of treatment with acetylsalicylic acid. One sample was transported by pneumatic tube transport, while the other remained in the laboratory.
Results: No preanalytical effect of pneumatic tube transport could be seen for most haematology and coagulation parameters, as well as analysis with PFA-100®. For the thromboelastographic analysis, time to clot formation was shorter (–16%, p=0.037) in the transported samples. Treatment with acetylsalicylic acid had no effect on the majority of the test results.
Conclusions: Pneumatic tube transport does not introduce preanalytical errors when transporting samples for analysis of routine haematology, coagulation parameters and platelet function with the PFA-100®. We recommend manual transport of samples for analysis with thromboelastographic techniques.
Clin Chem Lab Med 2008;46:1443–9.
©2008 by Walter de Gruyter Berlin New York
Articles in the same Issue
- Review
- Use of biochemical markers of bone turnover in the management of postmenopausal osteoporosis
- Minireview
- Is serum procalcitonin able to predict long-term kidney morbidity from urinary tract infections in children?
- Genetics and Molecular Diagnostics
- Association between the 2756A> G variant in the gene encoding methionine synthase and myocardial infarction in Tunisian patients
- Common 894G>T single nucleotide polymorphism in the gene coding for endothelial nitric oxide synthase (eNOS) and risk of congenital heart defects
- New sequence variants in BRCA1 and BRCA2 genes detected by high-resolution melting analysis in an elderly healthy female population in Croatia
- Enzyme-free signal amplification of analyte in a single closed tube by fluorescent hybridization chain reaction
- Five X-chromosome short tandem repeats in a Western Mexican population
- General Clinical Chemistry and Laboratory Medicine
- Prolyl-hydroxyproline dipeptide in non-hydrolyzed morning urine and its value in postmenopausal osteoporosis
- Methionine metabolism in an animal model of sepsis
- Hypochlorous acid is a potent inactivator of human plasminogen at concentrations secreted by activated granulocytes
- Association of serum γ-glutamyltransferase with C-reactive protein levels and white blood cell count in Korean adults
- Immunoradiometric determination of thyroglobulin in serum samples by time calibration transfer
- Serum interleukin 6 (IL-6) and C-reactive protein (CRP) levels in colorectal adenoma and cancer patients
- Measurement of 10,11-dihydro-10-hydroxy-carbamazepine in serum and plasma by high-performance liquid chromatography
- The relationship between usual coffee consumption and serum C-reactive protein level in a Japanese female population
- Reference Values and Biological Variations
- Analytical quality goals for parathyroid hormone based on biological variation
- Preanalytical effects of pneumatic tube transport on routine haematology, coagulation parameters, platelet function and global coagulation
- Validation and Outcome Studies
- Automated immunoassay methods for ferritin: recovery studies to assess traceability to an international standard
- An expert system for the classification of serum protein electrophoresis patterns
- Impact of a satellite laboratory on turnaround times for the emergency department
- Effect of ampicillin-sulbactam on clinical capillary zone electrophoresis of serum proteins
- Guidelines and Recommendations
- Protein standardization V: value transfer. A practical protocol for the assignment of serum protein values from a Reference Material to a Target Material
- Letter to the Editor
- Biological variability evaluation and comparison of three different methods for C-peptide measurement
- Abstracts
- 10.1515/CCLM.2008.361
Articles in the same Issue
- Review
- Use of biochemical markers of bone turnover in the management of postmenopausal osteoporosis
- Minireview
- Is serum procalcitonin able to predict long-term kidney morbidity from urinary tract infections in children?
- Genetics and Molecular Diagnostics
- Association between the 2756A> G variant in the gene encoding methionine synthase and myocardial infarction in Tunisian patients
- Common 894G>T single nucleotide polymorphism in the gene coding for endothelial nitric oxide synthase (eNOS) and risk of congenital heart defects
- New sequence variants in BRCA1 and BRCA2 genes detected by high-resolution melting analysis in an elderly healthy female population in Croatia
- Enzyme-free signal amplification of analyte in a single closed tube by fluorescent hybridization chain reaction
- Five X-chromosome short tandem repeats in a Western Mexican population
- General Clinical Chemistry and Laboratory Medicine
- Prolyl-hydroxyproline dipeptide in non-hydrolyzed morning urine and its value in postmenopausal osteoporosis
- Methionine metabolism in an animal model of sepsis
- Hypochlorous acid is a potent inactivator of human plasminogen at concentrations secreted by activated granulocytes
- Association of serum γ-glutamyltransferase with C-reactive protein levels and white blood cell count in Korean adults
- Immunoradiometric determination of thyroglobulin in serum samples by time calibration transfer
- Serum interleukin 6 (IL-6) and C-reactive protein (CRP) levels in colorectal adenoma and cancer patients
- Measurement of 10,11-dihydro-10-hydroxy-carbamazepine in serum and plasma by high-performance liquid chromatography
- The relationship between usual coffee consumption and serum C-reactive protein level in a Japanese female population
- Reference Values and Biological Variations
- Analytical quality goals for parathyroid hormone based on biological variation
- Preanalytical effects of pneumatic tube transport on routine haematology, coagulation parameters, platelet function and global coagulation
- Validation and Outcome Studies
- Automated immunoassay methods for ferritin: recovery studies to assess traceability to an international standard
- An expert system for the classification of serum protein electrophoresis patterns
- Impact of a satellite laboratory on turnaround times for the emergency department
- Effect of ampicillin-sulbactam on clinical capillary zone electrophoresis of serum proteins
- Guidelines and Recommendations
- Protein standardization V: value transfer. A practical protocol for the assignment of serum protein values from a Reference Material to a Target Material
- Letter to the Editor
- Biological variability evaluation and comparison of three different methods for C-peptide measurement
- Abstracts
- 10.1515/CCLM.2008.361