Startseite Technik Development of gamma spectroscopy employing NaI(Tl) detector 3 inch × 3 inch and readout electronic of flash-ADC/FPGA-based technology
Artikel
Lizenziert
Nicht lizenziert Erfordert eine Authentifizierung

Development of gamma spectroscopy employing NaI(Tl) detector 3 inch × 3 inch and readout electronic of flash-ADC/FPGA-based technology

  • Vo Hong Hai , Nguyen Quoc Hung und Bui Tuan Khai
Veröffentlicht/Copyright: 24. April 2015
Veröffentlichen auch Sie bei De Gruyter Brill

Abstract

In this article the development of a gamma spectroscopy system is described using a scintillation detector NaI(Tl) of 3 inch × 3 inch. The readout electronic for the spectroscopy is built from the fast analog-digital conversion of Flash Analog-Digital Converter (Flash-ADC) 250 MHz – 8 bits resolution, and the embedded Field-Programmable Gate Array (FPGA) technology. The embedded VHSIC Hardware Description Language (VHDL) code for FPGA is built in such a way that it works as a multi channel analyser (MCA) with 4096 Digital Charge Integration (DCI) channels. A pulse generator with frequency varying from Hz up to 12 kHz is used to evaluate the time response of the system. Two standard radioisotope sources of 133Ba and 152Eu with multi gamma energies ranging from several tens keV to MeV are used to evaluate the linearity and energy resolution of the system.

References

1 Charge Integration: Analog Vs. Digital manual, CAEN, Inc. [Online] http://www.caen.it/Suche in Google Scholar

2 Peachousek, J.; Prochazka, R.; Frydrych, J.: Virtual instrumentation techniques used in the nuclear digital signal processing system design: Energy and time measurement tests, Palacky University-Czech Republic, 201110.1016/j.nima.2011.02.024Suche in Google Scholar

3 Nomachi, M.: 250 MHz-8bits FADC and Trigger Interface, The collaboration program between Graduate school of Science, Osaka University and Faculty of Physics, University of Science-HCMC, 2009Suche in Google Scholar

4 Buzzetti, S.; Capou, M.; GuazzoniC.; et al.: High-speed FPGA-based pulse-height analyzer for high resolution x-ray spectroscopy. IEEE Trans. Nucl. Sci.52 (2002) 85486010.1109/TNS.2005.852699Suche in Google Scholar

5 Vo HongHai: Cosmic ray measurements employing plastic scintillation detectors and Flash-ADC/FPGA-Based readout system. Nuclear Science and Technology4 (2011) 5360Suche in Google Scholar

6 Vo HongHai; Nguyen QuocHung: Develop the detection system for cosmic ray measurements using Plastic scintillation detectors and Flash-ADC/FPGA-based readout performed at University of Science-Hochiminh. Proceeding of IAU-Vietnam Workshop on Astronomy and Astrophysics, 2011, pp. 105114Suche in Google Scholar

7 Hai, V. H.; Dao, N. Q.; NomachiM.: Cosmic ray angular distribution employing plastic scintillation detectors and flash-ADC/FPGA-based readout systems. Kerntechnik77 (2012) 46246410.3139/124.110204Suche in Google Scholar

8 http://www.altera.com/Suche in Google Scholar

9 NI LabVIEW software, National Instruments Corp., [Online] http://www.ni.com/labview/Suche in Google Scholar

10 http://www.canberra.com/Suche in Google Scholar

11 Spectrum Techniques, Ins. [Online] http://www.spectrumtechniques.com/Suche in Google Scholar

Received: 2014-12-25
Published Online: 2015-04-24
Published in Print: 2015-04-28

© 2015, Carl Hanser Verlag, München

Heruntergeladen am 13.12.2025 von https://www.degruyterbrill.com/document/doi/10.3139/124.110491/html
Button zum nach oben scrollen