Startseite Recording of focal direct current (DC) changes in the human cerebral cortex using refined non-invasive DC-EEG methodology
Artikel
Lizenziert
Nicht lizenziert Erfordert eine Authentifizierung

Recording of focal direct current (DC) changes in the human cerebral cortex using refined non-invasive DC-EEG methodology

  • Stefanie Leistner , Hans-Juergen Scheer , Tilmann Sander , Martin Burghoff , Lutz Trahms , Gabriel Curio und Bruno-Marcel Mackert
Veröffentlicht/Copyright: 22. Februar 2007
Veröffentlichen auch Sie bei De Gruyter Brill
Biomedical Engineering / Biomedizinische Technik
Aus der Zeitschrift Band 52 Heft 1

Abstract

A non-invasive DC electroencephalographic (DC-EEG) method was developed to record and analyze focal low-frequency (<0.1 Hz) DC changes in the human cerebral cortex. A simple repetitive finger-movement task was used as a physiological activation paradigm. DC-EEG amplitudes were recorded using a custom-made DC amplifier with automatic offset correction. A total of 16 standard Ag/AgCl electrodes covered the left primary motor cortex. In three of six subjects, reliable focal motor-related DC-EEG shifts over the hand cortex were monitored. This study demonstrates that refined DC-EEG recording and data analysis procedures allow non-invasive recording of low-frequency and low-amplitude focal cortical changes in humans. An important clinical perspective of this technology is the detection of stroke-associated cortical DC activity.


Corresponding author: Stefanie Leistner, Dept. of Neurology, Campus Benjamin Franklin, Charité– University Medicine Berlin, Hindenburgdamm 30, 12203 Berlin, Germany Phone: +49-30-8445-2276 Fax: +49-30-8445-4264

References

[1] Back T, Kohno K, Hossmann KA. Cortical negative DC deflections following middle cerebral artery occlusion and KCl-induced spreading depression: effect on blood flow, tissue oxygenation and electroencephalogram. J Cereb Blood Flow Metab1994; 14: 12–19.10.1038/jcbfm.1994.3Suche in Google Scholar

[2] Barkley GL, Moran JE, Takanashi Y, Tepley N. Techniques for DC magnetoencephalography. J Clin Neurophysiol1991; 8: 189–199.10.1097/00004691-199104000-00006Suche in Google Scholar

[3] Burghoff M, Sander TH, Schnabel A, Drung D, Curio G, Trahms L, Mackert BM. DC magnetoencephalography: direct measurement in a magnetically extremely well shielded room. Appl Phys Lett2004; 85: 6278–6280.10.1063/1.1836869Suche in Google Scholar

[4] Elbert T, Rockstroh B, Lutzenberger W, Birbaumer N. The influence of low-level, event-related DC currents during time estimation in humans. Int J Neurosci1981; 15: 103–106.10.3109/00207458108985850Suche in Google Scholar

[5] Gardner-Medwin AR, Tepley N, Barkley GL, et al. Magnetic fields associated with spreading depression in anaesthetized rabbits. Brain Res1991; 540: 153–158.10.1016/0006-8993(91)90502-MSuche in Google Scholar

[6] Kasischke KA, Vishwasrao HD, Fisher PJ, Zipfel WR, Webb WW. Neural activity triggers neuronal oxidative metabolism followed by astrocytic glycolysis. Science2004; 305: 99–103.10.1126/science.1096485Suche in Google Scholar

[7] Lagerlund TD, Gross RA. DC-EEG recording. A paradigm shift in seizure localization. Neurology2003; 60: 1062–1063.10.1212/WNL.60.7.1062Suche in Google Scholar

[8] Lauritzen M. Cortical spreading depression in migraine. Cephalalgia2001; 21: 757–760.10.1046/j.1468-2982.2001.00244.xSuche in Google Scholar

[9] Lauritzen M. Pathophysiology of the migraine aura. The spreading depression theory. Brain1994; 117: 199–210.10.1093/brain/117.1.199Suche in Google Scholar

[10] Leao AAP. The slow voltage variation of cortical spreading depression of activity. Electroecephalogr Clin Neurophysiol1951; 3: 315–321.10.1016/0013-4694(51)90079-XSuche in Google Scholar

[11] Mackert BM, Wubbeler G, Leistner S, Trahms L, Curio G. Non-invasive single-trial monitoring of human movement-related brain activation based on DC-magnetoencephalography. Neuroreport2001; 12: 1689–1692.10.1097/00001756-200106130-00034Suche in Google Scholar PubMed

[12] Mackert BM. The discovery of slowness – recent progress in DC-MEG research. Neurol Clin Neurophysiol2004; 30: 41–47.Suche in Google Scholar

[13] Müller W, Grunwald P, Riedel W, Burghoff M. Mehrkanal – Aufnahmesystem für Biosignale mit bis zu 512 analogen Eingängen. Biomed Tech2003; 48: 40–41.10.1515/bmte.2003.48.s1.40Suche in Google Scholar

[14] Niemann J, Winker T, Gerling J, Landwehrmeyer B, Jung R. Changes of slow cortical negative DC-potentials during the acquisition of a complex finger motor task. Exp Brain Res1991; 85: 417–422.10.1007/BF00229418Suche in Google Scholar PubMed

[15] Scheer HJ, Sander T, Burghoff M. A high resolution preamplifier for DC-EEG. Biomed Tech2005; 50(Suppl 1): 165–166.Suche in Google Scholar

[16] Scheer HJ, Sander T, Trahms L. The influence of amplifier, interface and biological noise in high resolution EEG recordings. Physiol Meas2006; 27: 109–117.10.1088/0967-3334/27/2/002Suche in Google Scholar PubMed

[17] Strong AJ, Fabricius M, Boutelle MG, et al. Spreading and synchronous depressions of cortical activity in acutely injured human brain. Stroke2002; 33: 2738–2743.10.1161/01.STR.0000043073.69602.09Suche in Google Scholar

[18] Okada Y, Lauritzen M, Nicholson C. MEG source models and physiology. Phys Med Biol1987; 32: 43–51.10.1088/0031-9155/32/1/007Suche in Google Scholar PubMed

[19] Tallgren P, Vanhatalo S, Kaila K, Voipio J. Evaluation of commercially available electrodes and gels for recording of slow EEG potentials. Clin Neurophysiol2005; 116: 799–806.10.1016/j.clinph.2004.10.001Suche in Google Scholar PubMed

[20] Vanhatalo S, Holmes MD, Tallgren P, Voipio J, Kaila K, Miller JW. Very slow EEG responses lateralize temporal lobe seizures: an evaluation of non-invasive DC-EEG. Neurology2003; 60: 1098–1104.10.1212/01.WNL.0000052993.37621.CCSuche in Google Scholar

[21] Vanhatalo S, Voipio J, Kaila K. Full-band EEG (FbEEG): an emerging standard in electroencephalography. Clin Neurophysiol2005; 116: 1–8.10.1016/j.clinph.2004.09.015Suche in Google Scholar PubMed

[22] Yoshinaga H, Nakahori T, Ohtsuka Y, et al. Benefit of simultaneous recording of EEG and MEG in dipole localization. Epilepsia2002; 43: 924–928.10.1046/j.1528-1157.2002.42901.xSuche in Google Scholar PubMed

Published Online: 2007-02-22
Published in Print: 2007-02-01

©2007 by Walter de Gruyter Berlin New York

Artikel in diesem Heft

  1. Ralph Mueller and Herbert Witte join the Associate Editor team of Biomedizinische Technik/Biomedical Engineering
  2. Technological innovations in information engineering demand sustained updating and upgrading in biosignal processing applications: a continual renaissance
  3. Predicting initiation and termination of atrial fibrillation from the ECG
  4. Predicting the QRS complex and detecting small changes using principal component analysis
  5. The role of independent component analysis in the signal processing of ECG recordings
  6. Implantable cardioverter defibrillator algorithms: status review in terms of computational cost
  7. Assessment of dynamic changes in cerebral autoregulation
  8. Corrected body surface potential mapping
  9. Autonomic cardiac control in animal models of cardiovascular diseases. I. Methods of variability analysis
  10. Autonomic cardiac control in animal models of cardiovascular diseases II. Variability analysis in transgenic rats with α-tropomyosin mutations Asp175Asn and Glu180Gly
  11. Fetal ECG extraction during labor using an adaptive maternal beat subtraction technique
  12. Heart rate variability in the fetus: a comparison of measures
  13. Estimation of spontaneous baroreflex sensitivity using transfer function analysis: effects of positive pressure ventilation
  14. Mobile nocturnal long-term monitoring of wheezing and cough
  15. Vigilance monitoring – review and practical aspects
  16. Coupled oscillators for modeling and analysis of EEG/MEG oscillations
  17. Auditory evoked potentials for the assessment of depth of anaesthesia: different configurations of artefact detection algorithms
  18. NeuMonD: a tool for the development of new indicators of anaesthetic effect
  19. Recording of focal direct current (DC) changes in the human cerebral cortex using refined non-invasive DC-EEG methodology
  20. Comparing a template approach and complex bandpass filtering for single-trial analysis of auditory evoked M100
  21. Wavelet-based analysis of MMN responses in children
  22. Branched EMG electrodes for stable and selective recording of single motor unit potentials in humans
  23. EMG analysis of the thenar muscles as a model for EMG-triggered larynx stimulation
  24. Physiological MR signal variations within the brain at 3 T
  25. Application of decorrelation-independent component analysis to biomagnetic multi-channel measurements
  26. A method for locating gradual changes in time series
  27. The use of digital signal processors (DSPs) in real-time processing of multi-parametric bioelectronic signals
  28. Steps towards a miniaturized, robust and autonomous measurement device for the long-term monitoring of patient activity: ActiBelt
  29. Motor timing and more – additional options using advanced registration and evaluation of tapping data
  30. Cellular signaling: aspects for tumor diagnosis and therapy
  31. List of reviewers engaged in the Special Issues on Biosignal Processing
  32. Stellungnahme zu „In vitro Langzeitkultur von humanem Knochen unter physiologischen Lastbedingungen“; Biomed Tech 2004; 49: 364–367
Heruntergeladen am 30.9.2025 von https://www.degruyterbrill.com/document/doi/10.1515/BMT.2007.019/html
Button zum nach oben scrollen