Long-term (in)stability of folate and vitamin B12 in human serum

  • Eugène H.J.M. Jansen EMAIL logo , Piet K. Beekhof , Johannes W.J.M. Cremers und Erna Schenk
Veröffentlicht/Copyright: 16. April 2012
Veröffentlichen auch Sie bei De Gruyter Brill

Abstract

Background: In epidemiological research it is very important to test the stability of biomarkers as a function of both storage time and temperature. In this study the stability of both folate and vitamin B12 in human serum samples have been tested after storage at three different temperatures up to 1 year.

Methods: Serum samples of 16 individuals were used in this study. The concentration of folate and vitamin B12 has been determined at T=0 and at several time points up to 1 year after storage at –20°C, –70°C and –196°C. The statistical difference from the initial value at T=0 were determined with a t-test.

Results: Folate in serum samples remained stable at –70°C but was not stable during storage at –20°C. A fast decrease was observed after Day 4 which resulted in a stable level of about 60% of the original value measured at T=0 (p<0.001). The rank order of folate concentration in the samples, however, was not affected. The stability of vitamin B12 was good at all temperatures tested.

Conclusions: Measurements of folate concentrations in serum stored at –20°C are not reliable. The rank order, however, was not changed. Vitamin B12 was stable at all temperatures tested. For both folate and vitamin B12 storage at –70°C is sufficient to maintain the original concentration for 1 year. Storage at –196°C in liquid nitrogen is not necessary for these nutrients.


Corresponding author: Eugène H.J.M. Jansen, Laboratory for Health Protection Research, National Institute of Public Health and the Environment, PO Box 1, 3720 BA Bilthoven, The Netherlands Phone: +31 302742940, Fax: +31 302744446

Received: 2012-2-21
Accepted: 2012-3-25
Published Online: 2012-04-16
Published in Print: 2012-10-01

©2012 by Walter de Gruyter Berlin Boston

Artikel in diesem Heft

  1. Masthead
  2. Masthead
  3. Editorials
  4. Cancer epigenomics: moving slowly, but at a steady pace from laboratory bench to clinical practice
  5. Laboratory networking and sample quality: a still relevant issue for patient safety
  6. Reviews
  7. DNA methylation biomarkers and their utility for solid cancer diagnostics
  8. DNA methylation biomarkers in biological fluids for early detection of respiratory tract cancer
  9. Global DNA hypomethylation in cancer: review of validated methods and clinical significance
  10. Genetics and Molecular Diagnostics
  11. δ0-Thalassemia in cis of βKnossos globin gene: first homozygous description in thalassemia intermedia Libyans and first combination with codon 39 (C→T) in thalassemia intermedia Tunisian patients
  12. Genetic-based reference values for angiotensin-converting enzyme (ACE) according to I/D polymorphism in a Spanish population sample
  13. General Clinical Chemistry and Laboratory Medicine
  14. Effects of sample transportation on commonly requested laboratory tests
  15. Long-term (in)stability of folate and vitamin B12 in human serum
  16. Information comparison of the effects of drugs on laboratory tests in drug labels and Young’s book
  17. First evaluation of Capillarys 2 Flex Piercing® (Sebia) as a new analyzer for HbA1c assay by capillary electrophoresis
  18. Antioxidant and oligonutrient status, distribution of amino acids, muscle damage, inflammation, and evaluation of renal function in elite rugby players
  19. Validation of the body fluid module on the new Sysmex XN-1000 for counting blood cells in cerebrospinal fluid and other body fluids
  20. Measuring Rivaroxaban in a clinical laboratory setting, using common coagulation assays, Xa inhibition and thrombin generation
  21. Cancer Diagnostics
  22. Increased concentrations of growth factors and activation of the EGFR system in breast cancer
  23. Infectious Diseases
  24. Incidence and significance of elevated lactate in the identification of critically ill patients
  25. Cardiovascular Diseases
  26. Lipoprotein-associated phospholipase A2 is elevated in patients with severe aortic valve stenosis without clinically overt atherosclerosis
  27. Diabetes
  28. Serum cystatin C as a marker for early detection of chronic kidney disease and grade 2 nephropathy in Japanese patients with type 2 diabetes
  29. Letters to the Editor
  30. Establishing professional phlebotomist group for quality control of the preanalytic variables of clinical laboratory
  31. Application of quality specification based on biological variation in planning quality control strategy
  32. Analytical and clinical evaluation of a new immunoassay for therapeutic drug monitoring of infliximab and adalimumab
  33. Comparison of relationships between FT4 and log TSH in Access DXI 800 Unicel, Modular E170 and ADVIA Centaur XP Analyzer
  34. Assay-specific pitfalls of catecholamine HPLC assays
  35. Evaluation of automated nucleated red blood cells counting on Sysmex XE5000 and Siemens ADVIA 2120
  36. Evaluation of the immature myeloid information (IMI) by Sysmex XE 2100® hematology analyzer in the identification of blasts of myeloid lineage
  37. Congress Abstracts
  38. Congress of Laboratory Medicine and Clinical Chemistry / 4th Annual Meeting of the Austrian Society for Laboratory Medicine and Clinical Chemistry (ÖGLMKC)
  39. Abstracts of the 2012 Convocation of Experts on Laboratory Quality / Embracing the Need of Continued Vigilance to Assure Quality Outcomes in the Modern Laboratory
Heruntergeladen am 12.9.2025 von https://www.degruyterbrill.com/document/doi/10.1515/cclm-2012-0108/html
Button zum nach oben scrollen