Abstract
Background: Equivalent results between different laboratories enable optimal patient care and can be achieved with harmonisation. We report on EQA-initiated national harmonisation of seven enzymes using commutable samples.
Methods: EQA samples were prepared from human serum spiked with human recombinant enzymes. Target values were assigned with the IFCC Reference Measurement Procedures. The same samples were included at four occasions in the EQA programmes of 2012 and 2013. Laboratories were encouraged to report IFCC traceable results. A parallel study was done to confirm commutability of the samples.
Results: Of the 223 participating laboratories, 95% reported IFCC traceable results, ranging from 98% (ASAT) to 87% (amylase). Users of Roche and Siemens (97%) more frequently reported in IFCC traceable results than users of Abbott (91%), Beckman (90%), and Olympus (87%). The success of harmonisation, expressed as the recovery of assigned values and the inter-laboratory CV was: ALAT (recovery 100%; inter-lab CV 4%), ASAT (102%; 4%), LD (98%; 3%), CK (101%; 5%), GGT (98%; 4%), AP (96%; 6%), amylase (99%; 4%). There were no significant differences between the manufacturers. Commutability was demonstrated in the parallel study. Equal results in the same sample in the 2012 and 2013 EQA programmes demonstrated stability of the samples.
Conclusions: The EQA-initiated national harmonisation of seven enzymes, using stable, commutable human serum samples, spiked with human recombinant enzymes, and targeted with the IFCC Reference Measurement Procedures, was successful in terms of implementation of IFCC traceable results (95%), recovery of the target (99%), and inter-laboratory CV (4%).
Acknowledgments
The authors acknowledge Dr. Joost Swaanenburg and Dr. Hans van der Vuurst for performing assays in their laboratory, Jeffrey Sigger for the collection of sera and Liesbeth Schröer-Jansen for processing the data.
Conflict of interest statement
Author’s conflict of interest disclosure: The authors stated that there are no conflicts of interest regarding the publication of this article.
Research funding: None declared.
Employment or leadership: None declared.
Honorarium: None declared.
References
1. Miller WG, Myers GL, Lou Ganzer M, Kahn SE, Schönbrunner ER, Thienpont LM, et al. Roadmap for harmonization of clinical laboratory measurement procedures. Clin Chem 2011;57:1108–17.10.1373/clinchem.2011.164012Search in Google Scholar PubMed
2. Available from: http://www.ifcc.org.Accessed 21 January, 2014.Search in Google Scholar
3. Available from: http://www.harmonization.net.Accessed 21 January, 2014.Search in Google Scholar
4. Plebani M. Harmonization in laboratory medicine: the complete picture. Clin Chem Lab Med 2013;51:741–51.10.1515/cclm-2013-0075Search in Google Scholar PubMed
5. AACC position statement harmonization of clinical laboratory test result. November 2013. Available from: http://www.aacc.org/gov/gov_affairs/Documents/Position_Statement-Harmonization_V11.pdf.Accessed 25 January, 2014.Search in Google Scholar
6. Infusino I, Panteghini M. Standardization in clinical enzymology. eJIFCC 2009;20:7 pages. Available from: http://www.ifcc.org/ifcc-communications-publications-division-(cpd)/ifcc-publications/eifcc-(journal)/e-journal-volumes/eifcc-2009-vol-20/vol-20-n%C2%BO-3/standardization-in-clinical-enzymology/. Accessed 3 February, 2014.Search in Google Scholar
7. Ceriotti F. The role of external quality assessment schemes in monitoring and improving the standardization process. Clin Chim Acta 2014. doi: 10.1016/j.cca.2013.12.032. Accessed 19 May, 2014 on www.pub.med.10.1016/j.cca.2013.12.032Search in Google Scholar PubMed
8. Miller WG, Jones GR, Horowitz GL, Weykamp C. Proficiency testing/external quality assessment: current challenges and future directions. Clin Chem 2011;57:1670–80.10.1373/clinchem.2011.168641Search in Google Scholar PubMed
9. Available from: www.bipm.org/committees/jc/jctlm. Accessed 25 January, 2014.Search in Google Scholar
10. Schumann G, Bonora R, Ceriotti F, Ferard G, Ferrero CA, Franck PF, et al. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase. Clin Chem Lab Med 2002;40:718–24.10.1515/CCLM.2002.124Search in Google Scholar PubMed
11. Schumann G, Bonora R, Ceriotti F, Ferard G, Ferrero CA, Franck PF, et al. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase. Clin Chem Lab Med 2002;40:725–33.10.1515/CCLM.2002.125Search in Google Scholar PubMed
12. Schumann G, Bonora R, Ceriotti F, Clerc-Renaud P, Ferrero CA, Ferard G, et al. Reference procedure for the measurement of catalytic concentration of creatine kinase. Clin Chem Lab Med 2002;40:635–42.10.1515/CCLM.2002.110Search in Google Scholar PubMed
13. Schumann G, Bonora R, Ceriotti F, Clerc-Renaud P, Ferrero CA, Ferard G, et al. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase. Clin Chem Lab Med 2002;40:643–8.10.1515/CCLM.2002.111Search in Google Scholar PubMed
14. Schumann G, Bonora R, Ceriotti F, Ferard G, Ferrero CA, Franck PF, et al. Reference procedure for the measurement of catalytic concentration of gamma-glutamyltransferase. Clin Chem Lab Med 2002;40:734–8.Search in Google Scholar
15. Schumann G, Klauke R, Canalias F, Bossert-Reuther S, Franck P, Gella FJ, et al. Reference procedure for the measurement of catalytic concentration of alkaline phosphatase. Clin Chem Lab Med 2011;49:1439–46.10.1515/CCLM.2011.621Search in Google Scholar PubMed
16. Schumann G, Aoki R, Ferrero C, Ehlers G, Ferard F, Javier G, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Clin Chem Lab Med 2006;44:1146–55.10.1515/CCLM.2006.212Search in Google Scholar PubMed
17. Schumann G, Canalias F, Joergensen PJ, Kang D, Lessinger JM, Klauke R, et al. IFCC reference procedures for measurement of the catalytic concentrations of enzymes: corrigendum, notes and useful advice. International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) – IFCC Scientific Division. Clin Chem Lab Med 2010;48:615–21.Search in Google Scholar
18. Baadenhuijsen H, Steigstra H, Cobbaert C, Kuypers A, Weykamp C, Jansen R. Commutability assessment of potential reference materials using a multi-centre split-patient-sample between-field-method (twin-study) design. Clin Chem 2002;48:1520–5.10.1093/clinchem/48.9.1520Search in Google Scholar
19. Baadenhuijsen H, Kuypers A, Weykamp C, Cobbaert C, Jansen R. External quality assessment in the Netherlands: time to introduce commutable survey specimens. Lessons from the Dutch “Calibration 2000” project. Clin Chem Lab Med 2005;43: 304–7.Search in Google Scholar
20. Cobbaert C, Weykamp C, Franck P, de Jonge R, Kuypers A, Steigstra H, et al. Systematic monitoring of standardisation and harmonisation status with commutable EQA-samples – five year experience from the Netherlands. Clin Chim Acta 2012;414:234–40.10.1016/j.cca.2012.09.027Search in Google Scholar PubMed
21. CLSI EP30-A. Characterization and qualification of commutable reference materials for laboratory medicine; approved guideline, EP 30AE. Wayne, PA: CLSI, 2010.Search in Google Scholar
Supplemental Material
The online version of this article (DOI: 10.1515/cclm-2014-0458) offers supplementary material, available to authorized users.
©2014 by De Gruyter
Articles in the same Issue
- Frontmatter
- Editorial
- From symptoms to biomarkers: a change of paradigm
- Reviews
- Biochemical markers in early diagnosis and management of systemic amyloidoses
- The accuracy of the anti-mitochondrial antibody and the M2 subtype test for diagnosis of primary biliary cirrhosis: a meta-analysis
- Genetics and Molecular Diagnostics
- Selection of an optimal method for co-isolation of circulating DNA and miRNA from the plasma of pregnant women
- General Clinical Chemistry and Laboratory Medicine
- Harmonisation of seven common enzyme results through EQA
- Harmonization in hemolysis detection and prevention. A working group of the Catalonian Health Institute (ICS) experience
- Adopting European Network for Health Technology Assessments (EunetHTA) core model for diagnostic technologies for improving the accuracy and appropriateness of blood gas analyzers’ assessment
- Impact of assay design on test performance: lessons learned from 25-hydroxyvitamin D
- Anti-ruthenium antibodies mimic macro-TSH in electrochemiluminescent immunoassay
- The relationship between the Spine Deformity Index, biochemical parameters of bone metabolism and vascular calcifications: results from the Epidemiological VERtebral FRACtures iTalian Study (EVERFRACT) in dialysis patients
- Quantification of polyclonal free light chains in clinical samples using a single turbidimetric immunoassay
- Global coagulation tests: their applicability for measuring direct factor Xa- and thrombin inhibition and reversal of anticoagulation by prothrombin complex concentrate
- Reference Values and Biological Variations
- The importance of individual biology in the clinical use of serum biomarkers for ovarian cancer
- The quality of diagnostic testing may be impaired during shipment of lithium-heparin gel tubes
- Cancer Diagnostics
- Serum human epididymis protein 4 (HE4) as a tumor marker in men with lung cancer
- Intestinal permeability in patients with metastatic colon cancer treated with patupilone
- Cardiovascular Diseases
- European multicenter analytical evaluation of the Abbott ARCHITECT STAT high sensitive troponin I immunoassay
- Infectious Diseases
- Early indicators of severity and construction of a risk model for prognosis based upon laboratory parameters in patients with hemorrhagic fever with renal syndrome
- Corrigendum
- Automated indirect immunofluorescence antinuclear antibody analysis is a standardized alternative for visual microscope interpretation
- Letters to the Editor
- The future of the laboratory information system – what are the requirements for a powerful system for a laboratory data management?
- Hypernatraemia in disguise
- Interference of therapeutic monoclonal immunoglobulins in the investigation of M-proteins
- The impact of exercise on the variation of serum free light chains
- Response to Jacobs: N Latex FLC serum free light-chain assays in patients with renal impairment
- Reply to Berlanga et al. (DOI 10.1515/cclm-2014-0420)
- Mean platelet volume in patients with non-alcoholic fatty liver disease: is mean platelet volume ready as a surrogate marker?
- False-positive D-dimer result in a latex-enhanced immunoassay caused by interfering human anti-mouse antibodies
- D-Dimer in normal pregnancy: determination of reference values for three commercially available assays
- Paraoxonase 2 sequence variation (c.311 C>G) is associated with a modest decrease in circulating LDL size in children and adolescents
- The effect of volume of hydrochloric acid preservation on 24-hour urinary catecholamine test
- Congress Abstracts
- Congress of Clinical Chemistry and Laboratory Medicine
- The 3rd EFLM-UEMS Congress
- 46th National Congress of the Italian Society of Clinical Biochemistry and Clinical Molecular Biology (SIBioC – Laboratory Medicine)
Articles in the same Issue
- Frontmatter
- Editorial
- From symptoms to biomarkers: a change of paradigm
- Reviews
- Biochemical markers in early diagnosis and management of systemic amyloidoses
- The accuracy of the anti-mitochondrial antibody and the M2 subtype test for diagnosis of primary biliary cirrhosis: a meta-analysis
- Genetics and Molecular Diagnostics
- Selection of an optimal method for co-isolation of circulating DNA and miRNA from the plasma of pregnant women
- General Clinical Chemistry and Laboratory Medicine
- Harmonisation of seven common enzyme results through EQA
- Harmonization in hemolysis detection and prevention. A working group of the Catalonian Health Institute (ICS) experience
- Adopting European Network for Health Technology Assessments (EunetHTA) core model for diagnostic technologies for improving the accuracy and appropriateness of blood gas analyzers’ assessment
- Impact of assay design on test performance: lessons learned from 25-hydroxyvitamin D
- Anti-ruthenium antibodies mimic macro-TSH in electrochemiluminescent immunoassay
- The relationship between the Spine Deformity Index, biochemical parameters of bone metabolism and vascular calcifications: results from the Epidemiological VERtebral FRACtures iTalian Study (EVERFRACT) in dialysis patients
- Quantification of polyclonal free light chains in clinical samples using a single turbidimetric immunoassay
- Global coagulation tests: their applicability for measuring direct factor Xa- and thrombin inhibition and reversal of anticoagulation by prothrombin complex concentrate
- Reference Values and Biological Variations
- The importance of individual biology in the clinical use of serum biomarkers for ovarian cancer
- The quality of diagnostic testing may be impaired during shipment of lithium-heparin gel tubes
- Cancer Diagnostics
- Serum human epididymis protein 4 (HE4) as a tumor marker in men with lung cancer
- Intestinal permeability in patients with metastatic colon cancer treated with patupilone
- Cardiovascular Diseases
- European multicenter analytical evaluation of the Abbott ARCHITECT STAT high sensitive troponin I immunoassay
- Infectious Diseases
- Early indicators of severity and construction of a risk model for prognosis based upon laboratory parameters in patients with hemorrhagic fever with renal syndrome
- Corrigendum
- Automated indirect immunofluorescence antinuclear antibody analysis is a standardized alternative for visual microscope interpretation
- Letters to the Editor
- The future of the laboratory information system – what are the requirements for a powerful system for a laboratory data management?
- Hypernatraemia in disguise
- Interference of therapeutic monoclonal immunoglobulins in the investigation of M-proteins
- The impact of exercise on the variation of serum free light chains
- Response to Jacobs: N Latex FLC serum free light-chain assays in patients with renal impairment
- Reply to Berlanga et al. (DOI 10.1515/cclm-2014-0420)
- Mean platelet volume in patients with non-alcoholic fatty liver disease: is mean platelet volume ready as a surrogate marker?
- False-positive D-dimer result in a latex-enhanced immunoassay caused by interfering human anti-mouse antibodies
- D-Dimer in normal pregnancy: determination of reference values for three commercially available assays
- Paraoxonase 2 sequence variation (c.311 C>G) is associated with a modest decrease in circulating LDL size in children and adolescents
- The effect of volume of hydrochloric acid preservation on 24-hour urinary catecholamine test
- Congress Abstracts
- Congress of Clinical Chemistry and Laboratory Medicine
- The 3rd EFLM-UEMS Congress
- 46th National Congress of the Italian Society of Clinical Biochemistry and Clinical Molecular Biology (SIBioC – Laboratory Medicine)