Startseite Application of umbelliferone molecularly imprinted polymer in analysis of plant samples
Artikel
Lizenziert
Nicht lizenziert Erfordert eine Authentifizierung

Application of umbelliferone molecularly imprinted polymer in analysis of plant samples

  • Katarína Hroboňová EMAIL logo , Andrea Spevak , Ľubica Spišská , Jozef Lehotay und Jozef Čižmárik
Veröffentlicht/Copyright: 14. Februar 2013
Veröffentlichen auch Sie bei De Gruyter Brill

Abstract

The molecularly imprinted polymers (MIPs) were synthesised and the influence of the type of porogen, the nature of sample solvent, and the binding capacity of material were tested by high-performance liquid chromatography (HPLC). Umbelliferone was used as the template for imprint formation. Methacrylic acid was used as the monomer and acetonitrile, ethanol, and chloroform as porogen. Non-imprinted polymers (NIPs) were prepared by the same procedure. The highest value of the specific binding capacity (269 μg of umbelliferone per 100 mg of polymer) was obtained for polymers prepared in chloroform as porogen and methanol/water (φ r = 1: 1) as the sample solvent. The group-selective MIP was used as sorbent for the SPE pre-treatment of umbelliferone from plant extracts prior to HPLC analysis. Analysis of the spiked samples showed good recoveries (> 77 %). The limit of detection, limit of determination, and repeatability of the method were also calculated.

[1] Blahová, E., & Brandšteterová, E. (2004). Approaches in sample handling before HPLC analysis of complex matrices. Chemical Papers, 58, 362–373. Suche in Google Scholar

[2] Ciésla, Ł., & Waksmundzka-Hajnos, M. (2009). Two-dimensional thin-layer chromatography in the analysis of secondary plant metabolites. Journal of Chromatography A, 1216, 1035–1052. DOI: 10.1016/j.chroma.2008.12.057. http://dx.doi.org/10.1016/j.chroma.2008.12.05710.1016/j.chroma.2008.12.057Suche in Google Scholar

[3] Chen, D., Wang, J., Jiang, Y., Zhou, T., Fan, G., & Wu, Y. (2009). Separation and determination of coumarins in Fructus cnidii extracts by pressurized capillary electrochromatography using a packed column with a monolithic outlet frit. Journal of Pharmaceutical and Biomedical Analysis, 50, 695–702. DOI: 10.1016/j.jpba.2009.05.026. http://dx.doi.org/10.1016/j.jpba.2009.05.02610.1016/j.jpba.2009.05.026Suche in Google Scholar

[4] Dawa, Z., Zhou, Y., Bai, Y., Gesang, S., Bai, B., & Ding, L. (2008). Development of an HPLC-DAD-ESI-MSn method for quantitative analysis of Saussurea tridactyla. Journal of Pharmaceutical and Biomedical Analysis, 48, 1076–1081. DOI: 10.1016/j.jpba.2008.08.016. http://dx.doi.org/10.1016/j.jpba.2008.08.01610.1016/j.jpba.2008.08.016Suche in Google Scholar

[5] Dias, A. C. B., Figueiredo, E. C., Grassi, V., Zagatto, E. A. G., & Arruda, M. A. Z. (2008). Molecularly imprinted polymer as a solid phase extractor in flow analysis. Talanta, 76, 988–996. DOI: 10.1016/j.talanta.2008.05.040. http://dx.doi.org/10.1016/j.talanta.2008.05.04010.1016/j.talanta.2008.05.040Suche in Google Scholar

[6] Fernández Izquierdo, M. E., Quesada Granados, J., Villalon Mir, M., & López Martinez, M. C. (2000). Comparison of methods for determining coumarins in distilled beverages. Food Chemistry, 70, 251–258. DOI: 10.1016/s0308-8146(00)00071-6. http://dx.doi.org/10.1016/S0308-8146(00)00071-610.1016/S0308-8146(00)00071-6Suche in Google Scholar

[7] Fonseca, F. N., Tavares, M. F. M., & Horváth, C. (2007). Capillary electrochromatography of selected phenolic compounds of Chamomilla recutita. Journal of Chromatography A, 1154, 390–399. DOI: 10.1016/j.chroma.2007.03.106. http://dx.doi.org/10.1016/j.chroma.2007.03.10610.1016/j.chroma.2007.03.106Suche in Google Scholar

[8] Haupt, K., Dzgoev, A., & Mosbach, K. (1998). Assay system for the herbicide 2,4-dichlorophenoxyacetic acid using a molecu larly imprinted polymer as an artificial recognition element. Analytical Chemistry, 70, 628–631. DOI: 10.1021/ac9711549. http://dx.doi.org/10.1021/ac971154910.1021/ac9711549Suche in Google Scholar

[9] Hoult, J. R. S., & Paya, M. (1996). Pharmacological and biochemical actions of simple coumarins: natural products with therapeutic potential. General Pharmacology, 27, 713–722. DOI: 10.1016/0306-3623(95)02112-4. http://dx.doi.org/10.1016/0306-3623(95)02112-410.1016/0306-3623(95)02112-4Suche in Google Scholar

[10] Jurd, L., King, A. D., Jr., & Mihara, K. (1971). Antimicrobial properties of umbelliferone derivatives. Phytochemistry, 10, 2965–2970. DOI: 10.1016/s0031-9422(00)97333-3. http://dx.doi.org/10.1016/S0031-9422(00)97333-310.1016/S0031-9422(00)97333-3Suche in Google Scholar

[11] Kaneko, T., Baba, N., & Matsuo, M. (2003). Protection of coumarins against linoleic acid hydroperoxide-induced cytotoxicity. Chemico-Biological Interactions, 142, 239–254. DOI: 10.1016/s0009-2797(02)00077-7. http://dx.doi.org/10.1016/S0009-2797(02)00077-710.1016/S0009-2797(02)00077-7Suche in Google Scholar

[12] Lépinay, S., Kham, K., Millot, M. C., & Carbonnier, B. (2012). In-situ polymerized molecularly imprinted polymeric thin films used as sensing layers in surface plasmon resonance sensors: Mini-review focused on 2010–2011. Chemical Papers, 66, 340–351. DOI: 10.2478/s11696-012-0134-6. http://dx.doi.org/10.2478/s11696-012-0134-610.2478/s11696-012-0134-6Suche in Google Scholar

[13] Malik, A., Kushnoor, A., Saini, V., Singhal, S., Kumar, S., & Yadav, Y. C. (2012). Analytical methods development of nutraceutical: Umbelliferone. Pharma Science Monitor: An International Journal of Pharmaceutical Sciences, 3, 67–73. Suche in Google Scholar

[14] Micke, G. A., Moraes, E. P., Farah, J. P. S., & Tavares, M. F. M. (2003). Assessing the separation of neutral plant secondary metabolites by micellar electrokinetic chromatography. Journal of Chromatography A, 1004, 131–143. DOI: 10.1016/s0021-9673(03)00935-x. http://dx.doi.org/10.1016/S0021-9673(03)00935-X10.1016/S0021-9673(03)00935-XSuche in Google Scholar

[15] Nie, J. F., Wu, H. L., Zhu, S. H., Han, Q. J., Fu, H. Y., Li, S. F., & Yu, R. Q. (2008). Simultaneous determination of 6-methylcoumarin and 7-methoxycoumarin in cosmetics using three-dimensional excitation-emission matrix fluorescence coupled with second-order calibration methods. Talanta, 75, 1260–1269. DOI: 10.1016/j.talanta.2008.01.026. http://dx.doi.org/10.1016/j.talanta.2008.01.02610.1016/j.talanta.2008.01.026Suche in Google Scholar

[16] Nováková, L., Vildová, A., Mateus, J. P., Gonçalves, T., & Solich, P. (2010). Development and application of UHPLC-MS/MS method for the determination of phenolic compounds in Camomile flowers and Camomile tea extracts. Talanta, 82, 1271–1280. DOI: 10.1016/j.talanta.2010.06.057. http://dx.doi.org/10.1016/j.talanta.2010.06.05710.1016/j.talanta.2010.06.057Suche in Google Scholar

[17] Sgorbini, B., Ruosi, M. R., Cordero, C., Liberto, E., Rubiolo, P., & Bicchi, C. (2010). Quantitative determination of some volatile suspected allergens in cosmetic creams spread on skin by direct contact sorptive tape extraction-gas chromatography-mass spectrometry. Journal of Chromatography A, 1217, 2599–2605. DOI: 10.1016/j.chroma.2009.12. 052. http://dx.doi.org/10.1016/j.chroma.2009.12.05210.1016/j.chroma.2009.12.052Suche in Google Scholar

[18] Solich, P., Polášek., M., & Karlíček, R. (1995). Sequential flowinjection spectrofluorimetric determination of coumarins using a double-injection single-line system. Analytica Chimica Acta, 308, 293–298. DOI: 10.1016/0003-2670(94)00660-e. http://dx.doi.org/10.1016/0003-2670(94)00660-E10.1016/0003-2670(94)00660-ESuche in Google Scholar

[19] Su, J., Zhang, C., Zhang, W., Shen, Y. H., Li, H. L, Liu, R. H., Zhang, X., Hu, X. J., & Zhang, W. D. (2009). Qualitative and quantitative determination of the major coumarins in Zushima by high performance liquid chromatography with diode array and mass spectrometry. Journal of Chromatography A, 1216, 2111–2117. DOI: 10.1016/j.chroma.2008.06.015. http://dx.doi.org/10.1016/j.chroma.2008.06.01510.1016/j.chroma.2008.06.015Suche in Google Scholar PubMed

[20] Tamayo, F. G., Turiel, E., & Martín-Esteban, A. (2007). Molecularly imprinted polymers for solid-phase extraction and solid-phase microextraction: Recent developments and future trends. Journal of Chromatography A, 1152, 32–40. DOI: 10.1016/j.chroma.2006.08.095. http://dx.doi.org/10.1016/j.chroma.2006.08.09510.1016/j.chroma.2006.08.095Suche in Google Scholar PubMed

[21] Wang, W., Tang, J., Wang, S., Zhou, L., & Hu, Z. (2007). Method development for the determination of coumarin compounds by capillary electrophoresis with indirect laserinduced fluorescence detection. Journal of Chromatography A, 1148, 108–114. DOI: 10.1016/j.chroma.2006.09.070. http://dx.doi.org/10.1016/j.chroma.2006.09.07010.1016/j.chroma.2006.09.070Suche in Google Scholar PubMed

[22] Zheng, C., Huang, Y. P., & Liu, Z. S. (2011). Rescent developments and applications of molecularly imprinted monolithic column for HPLC and CEC. Journal of Separation Science, 34, 1988–2002. DOI: 10.1002/jssc.201100164. 10.1002/jssc.201100164Suche in Google Scholar PubMed

Published Online: 2013-2-14
Published in Print: 2013-5-1

© 2013 Institute of Chemistry, Slovak Academy of Sciences

Heruntergeladen am 27.11.2025 von https://www.degruyterbrill.com/document/doi/10.2478/s11696-013-0320-1/html
Button zum nach oben scrollen