Home Technology Radon in Austria: metrology and practice
Article
Licensed
Unlicensed Requires Authentication

Radon in Austria: metrology and practice

  • F. J. Maringer
Published/Copyright: April 5, 2013
Become an author with De Gruyter Brill

Abstract

The implementation of radon mitigation and precaution standards needs continuously scientific attendance and research networking on international level. Otherwise the radon issue could degrade easily to a simplified techno-economical exercise without sustainable results in public health. In this paper the radon investigations in Austria which have been carried out in the last 20 years and the applied methods and derived standards for mitigation and precaution at home and workplaces are discussed. Future strategies, scientific and social necessities to solve the radon problem are outlined comprehensively. The agreed and proposed future research objectives and cooperations in Austria that seem absolutely necessary are discussed in consideration of the medium-term perspective of the European radiation protection.

Kurzfassung

Die Umsetzung der Standards für Radonsanierungs- und Vorsorgemaßnahmen erfordert eine kontinuierliche Begleitung durch vernetzte Forschung auf internationalem Niveau. Andernfalls würde das Radonthema zunehmend zu einer simplen technisch-ökonomischen Übung ohne nachhaltiges volksgesundheitliches Ergebnis degenerieren. In dieser Arbeit werden die in den vergangenen 20 Jahren durchgeführten Untersuchungen in Österreich, die dabei angewandten Methoden und davon abgeleiteten Normen für Radonsanierung und Radonvorsorge diskutiert. Die zukünftigen Strategien, die wissenschaftlichen und sozialen Notwendigkeiten zur Lösung des Radonproblems werden zusammenfassend skizziert. Die dafür notwendigen bereits vereinbarten oder vorgeschlagenen zukünftigen Forschungsthemen und Forschungskooperationen in Österreich werden unter Berücksichtigung der mittelfristigen Perspektive im europäischen Strahlenschutzsektor diskutiert.

References

1 Friedmann, H.: Final Results of the Austrian Radon Project. Health Physics89 (4): 2005, pp. 33934810.1097/01.HP.0000167228.18113.27Search in Google Scholar

2 Maringer, F. J.; Lueginger, S.; Akis, M. C.; Kaineder, H.; Kindl, P.; Kralik, C.; Lettner, H.; Nadschläger, E.; Ringer, W.; Rolle, R.; Schönhofer, F.; Sperker, S.; Stadtmann, H.; Steger, F.; Steinhäusler, F.; Tschurlovits, M.; Winkler, R.: Results and conclusions of the Austrian radon mitigation project ‘SARAH’. Proc Radon in the living environment. Ed. Simonoupulos, S. E., Scivyer, Ch. Athens, 19–23 April 1999. Nat. Techn. Univ. Athens, Greece, 2000, pp. 12051218Search in Google Scholar

3 Maringer, F. J.; Kaineder, H.; Nadschläger, E.; Sperker, S.; Karg, V.; Ringer, W.: Radon in oberösterreichischen Kindergärten: Erhebung, Sanierung und Vorsorge. (Radon in Upper Austrian kindergartens: investigation, mitigation and precaution.) Publikationsreihe Fortschritte im Strahlenschutz. Strahlenschutz für Mensch und Gesellschaft im Europa von Morgen. TÜV-Verlag GmbH, München. 2001, pp. 162165 (in German)Search in Google Scholar

4 ÖNORM S 5250-1: Radon, Messverfahren und deren Anwendungsbereiche. (Radon, measuring procedures and their applications.) Österreichisches Normungsinstitut, Wien, 1998 (in German)Search in Google Scholar

5 ÖNORM S 5280-2: Radon Teil 2: Technische Vorsorgemaßnahmen bei Gebäuden. (Radon part 2: Constructive precaution measures for buildings.) Österreichisches Normungsinstitut, Wien, 2003 (in German)Search in Google Scholar

6 ÖNORM S 5280-3: Radon Teil 3: Sanierungsmaßnahmen an Gebäuden. (Radon part 3: Mitigation measures for buildings.) Österreichisches Normungsinstitut, Wien, 2005 (in German)Search in Google Scholar

7 Röttger, A.; Honig, A.; Schmidt, V.; Buchröder, H.; Rox, A.; Butterweck, G.; Schuler, Ch.; Maringer, F. J.; Michielsen, N.; Howarth, C., Miles, J. C. H.; Vargas, A.; Ortega, X.; Burian, I.; TurtiainenT.; Jachs, P.; Edelmaier, R. & Hagberg, N.: Comparison of calibration facilities for radon activity concentration: Euromet Project 657. Metrologia42, Tech. Suppl., 06003, 200510.1088/0026-1394/42/1A/06003Search in Google Scholar

8 Euromet: Comparison of calibration facilities for the radon activity concentration. Euromet Project 657, Final Report – 2005-02-01 (http://www.bipm.org/utils/common/pdf/final_reports/RI/EUROMET.RI(II)-S1/EUROMET.RI(II)-S1.Rn-222.pdf:2006-07-07)Search in Google Scholar

9 Maringer, F. J.; Hamernik, E.; Edelmaier, R.; Kreuziger, M.; Schönhofer, F.: „Radium, Radon und Folgeprodukte in Raumluft und Trinkwasser: Vergleich von Untersuchungsmethoden, Anwendungsbeispiele“ (Radium, radon and progenies in indoor air and drinking water: a comparison of analaytical methods.) Proc. „Radon“, 14. Arbeitstagung der ÖSRAD/ÖVS, 4. Juni 1992, Wien. Seibersdorf: ÖVS, 1993, pp. 6876 (in German)Search in Google Scholar

10 Maringer, F. J.; Kindl, P.; Mossbauer, L. & Stadtmann, H.: Measurement of Radon in Practice – a Comparison of Methods. in: Norbert Vana und Alfred Hefner (ed): Proc. Austr.-Ital.-Hung. Rad. Prot. Symp., 28–30 April 1993, Obergurgl/Tirol. Vol. 3. Seiberdorf: (ÖVS). 1994, pp. 427431Search in Google Scholar

11 Maringer, F. J.; Kaineder, H.; Kindl, P.; Lettner, H.; Mossbauer, L. & Saidler, C. H.: Bestimmung von Radon und Radonfolgeprodukten in Luft: Eine aktuelle Vergleichsmessung. (Determination of radon and radon progenies in air: a current comparison exercise.) Mitt. Österr. Geol. Ges. 88. Wien, 1997 (in German)Search in Google Scholar

12 Maringer, F. J.; Ramer, A.: Ergebnis des Ringvergleichs für Radon-Detektoren und Radonmessgeräte „Radonring 99“. (Result of the intercomparison of radon detectors and instruments “Radonring 99”.) Österreichisches Forschungs- und Prüfzentrum Arsenal GmbH, Wien, 1999 (in German)Search in Google Scholar

13 Maringer, F. J.; Baumgartner, A.; Michai, P.; Kreuziger, M.: Ergebnis der Vergleichsmessung für Radonmessgeräte und Radondetektoren ‘BEV-Radonring 2005’. Endbericht. (Result of the comparison exercise of radon instruments and detectors ‘BEV-Radonring 2005’. Final report.)Physikalisch-technischer Prüfdienst des Bundesamts für Eich- und Vermessungswesen, Wien, 2006 (in German)Search in Google Scholar

Received: 2007-11-2
Published Online: 2013-04-05
Published in Print: 2008-05-01

© 2008, Carl Hanser Verlag, München

Downloaded on 11.12.2025 from https://www.degruyterbrill.com/document/doi/10.3139/124.100551/html
Scroll to top button