Startseite The real time optical transmittance of swollen heterogeneous natural rubber/poly (ethylene-co-vinyl acetate) blends
Artikel
Lizenziert
Nicht lizenziert Erfordert eine Authentifizierung

The real time optical transmittance of swollen heterogeneous natural rubber/poly (ethylene-co-vinyl acetate) blends

  • Satheesh Chandran , Ashok Panayamthatta , Ravi Varma und Sujith Athiyanathil EMAIL logo
Veröffentlicht/Copyright: 30. Juli 2016
Veröffentlichen auch Sie bei De Gruyter Brill

Abstract

This work demonstrates a novel simple method to study the accurate real time optical transparency of a crosslinked polymer blend during its swelling in good solvent. Heterogeneous natural rubber (NR) and poly (ethylene-co-vinyl acetate) (EVA) blends were used for this experiment. Aromatic solvents such as benzene, toluene and xylene were used as the probe molecules. Optical transparency of the samples increases with increase in EVA content in the blends during swelling. The penetrant solvent molecular size also affects the optical transparency of the blends. This new method can effectively measure the optical transparency of polymer gels during their swelling. Also, these blends can be a promising material for optical switching.

References

[1] Haraguchi K, Li H-J, Song L, Murata K. Macromolecules 2007, 40, 6973–6980.10.1021/ma071348iSuche in Google Scholar

[2] Toyotama A, Sawada T, Yamanaka J, Kitamura K. Langmuir 2006, 22, 1952–1954.10.1021/la052395bSuche in Google Scholar

[3] Bae YH, Huh KM, Kim Y, Park K-H. J. Controlled Release 2000, 64, 3–13.10.1016/S0168-3659(99)00126-1Suche in Google Scholar

[4] Gulsen D, Chuhan A. J. Membr. Sci. 2006, 269, 35–48.10.1016/j.memsci.2005.06.024Suche in Google Scholar

[5] Tang Y, Lu JR, Lewis AL, Vick TA, Stratford PW. Macromolecules 2001, 34, 8768–8776.10.1021/ma010476iSuche in Google Scholar

[6] Takahashi S, Okada H, Nobukawa S, Yamaguchi M. Eur. Polym. J. 2012, 48, 974–980.10.1016/j.eurpolymj.2012.02.009Suche in Google Scholar

[7] Cemek B, Demir Y. Polym. Test. 2005, 24, 284–289.10.1016/j.polymertesting.2004.11.007Suche in Google Scholar

[8] Yildiz Y, Hepuzer Y, Yagci, Y, Pekcan O. Eur. Polym. J. 2002, 38, 1591–1599.10.1016/S0014-3057(02)00050-2Suche in Google Scholar

[9] Sujith A, Unnikrishnan G. J. Polym. Res. 2006, 13, 171–180.10.1007/s10965-005-9021-ySuche in Google Scholar

[10] Sujith A, Radhakrishnan CK, Unnikrishnan G, Thomas S. J. Appl. Polym. Sci. 2003, 90, 2691–2702.10.1002/app.12923Suche in Google Scholar

Received: 2015-6-2
Accepted: 2016-6-7
Published Online: 2016-7-30
Published in Print: 2017-3-1

©2017 Walter de Gruyter GmbH, Berlin/Boston

Heruntergeladen am 3.12.2025 von https://www.degruyterbrill.com/document/doi/10.1515/polyeng-2015-0235/html?lang=de
Button zum nach oben scrollen