Startseite Speed of sample transportation by a pneumatic tube system can influence the degree of hemolysis
Artikel
Lizenziert
Nicht lizenziert Erfordert eine Authentifizierung

Speed of sample transportation by a pneumatic tube system can influence the degree of hemolysis

  • Aseem Kumar Tiwari EMAIL logo , Prashant Pandey , Surbhi Dixit und Vimarsh Raina
Veröffentlicht/Copyright: 10. November 2011
Veröffentlichen auch Sie bei De Gruyter Brill

Abstract

Background: The objective of the study was to find the incidence of hemolysis in samples transported through a pneumatic tube system (PTS) at different speeds.

Methods: This prospective observational study was done in three phases: “short distance and high speed (115 m at 3 m/s)”, “long distance and high speed (225 m at 3 m/s)” and “short distance and slow speed (115 at 2 m/s)”. Fifty-two, 215 and 45 serum tube pairs, respectively, were evaluated in these three phases. A set of tubes was sent by PTS while the other was hand-carried. Samples were analyzed for supernatant hemoglobin (Hb), potassium (K+) and lactate dehydrogenase (LD).

Results: Mean transit time of samples through the PTS was much shorter as compared to human courier in all three phases. LD was elevated in PTS arm in the “short distance and high speed” phase and in the “long distance and high speed” phase, all three indices of hemolysis – Hb, K+ and LD – showed elevation in the PTS arm. However, at “short distance and slow speed” phase, there was no hemolysis in the PTS arm.

Conclusions: Hospitals should validate their PTS before use and, by altering speed of sample transportation, hemolysis may be obliterated.


Corresponding author: Dr. Aseem Kumar Tiwari, MD, Consultant, Department of Transfusion Medicine, Medanta-The Medicity Hospital, Sector-38, Gurgaon, 122001 –Haryana, India Phone: +91 124 4141 414, Fax: +91 124 4834 111

Received: 2011-7-28
Accepted: 2011-10-17
Published Online: 2011-11-10
Published in Print: 2012-03-01

©2012 by Walter de Gruyter Berlin Boston

Artikel in diesem Heft

  1. Editorials
  2. An appeal to medical journal editors: the need for a full description of laboratory methods and specimen handling in clinical study reports
  3. Cancer diagnosis: from dogs to DNA or from DNA to dogs?
  4. The never-ending search of an acceptable compromise for pancreatic lipase standardisation
  5. Review
  6. Hereditary breast cancer: beyond BRCA genetic analysis; PALB2 emerges
  7. Mini Review
  8. Canine olfactory detection of cancer versus laboratory testing: myth or opportunity?
  9. Genetics and Molecular Diagnostics
  10. SLCO1B1 gene variability influences lipid-lowering efficacy on simvastatin therapy in Southern Brazilians
  11. Elevated plasma matrix metalloproteinase-9 protein and its gene polymorphism in patients with community-acquired pneumonia
  12. General Clinical Chemistry and Laboratory Medicine
  13. Minimum analytical quality specifications of inter-laboratory comparisons: agreement among Spanish EQAP organizers
  14. Monitoring quality indicators in laboratory medicine does not automatically result in quality improvement
  15. Speed of sample transportation by a pneumatic tube system can influence the degree of hemolysis
  16. 1,2-Dioleoylglycerol method for pancreatic lipase catalytic activity in serum
  17. Serum lactate dehydrogenase levels significantly correlate with radiological extent of disease and spirometric values in patients with silicosis due to denim sandblasting
  18. Clinical comparison of new monoclonal antibody-based nephelometric assays for free light chain kappa and lambda to polyclonal antibody-based assays and immunofixation electrophoresis
  19. The relationship between antinuclear antibody data and antibodies against extractable nuclear antigens in a large laboratory cohort
  20. Anti-neutrophil cytoplasmic antibodies (ANCA) specific for one or several antigens: useful markers for subtypes of ulcerative colitis and associated primary sclerosing cholangitis
  21. Trueness in the measurement of haemoglobin: consensus or reference method?
  22. Soluble transcobalamin receptor, sCD320, is present in human serum and relates to serum cobalamin – establishment and validation of an ELISA
  23. An on-line solid phase extraction procedure for the routine quantification of caspofungin by liquid chromatography-tandem mass spectrometry
  24. Effects of subcutaneous low molecular weight heparin and intravenous unfractionated heparin on serum S100 concentrations in patients with cerebrovascular diseases
  25. Urinary 8-hydroxy-2′-deoxyguanosine level and plasma paraoxonase 1 activity with Alzheimer’s disease
  26. A HPLC-MS method to detect and quantify guanfacine in urine
  27. Collection and storage requirements for urinary kidney injury molecule-1 (KIM-1) measurements in humans
  28. Kidney stones in a Mediterranean population from the south of Spain
  29. Reference Values and Biological Variations
  30. First trimester biochemistry at different maternal ages
  31. Age- and gender-related alteration in plasma advanced oxidation protein products (AOPP) and glycosaminoglycan (GAG) concentrations in physiological ageing
  32. Cancer Diagnostics
  33. Direct sequencing in cytological specimens as a useful strategy for detecting EGFR mutations in non-small cell lung cancer patients
  34. Investigation of lung cancer biomarkers by hyphenated separation techniques and chemometrics
  35. Letters to the Editor
  36. Aberrant results observed with four immuno-assays for total and free prostate-specific antigen (PSA) determination: a case-report
  37. Assay-dependent abnormalities in measurements of prostate-specific antigen in serum: an occasional occurrence, but of clinical significance
  38. Clinical comparison of new monoclonal antibody-based nephelometric assays for free light chain κ and λ to polyclonal antibody-based assays and immunofixation electrophoresis
  39. Agarose-gel electrophoresis for the diagnosis of mucopolysaccharidoses
  40. Leptin levels in exhaled breath condensate from asthmatic children: a pilot study
  41. Masthead
  42. Masthead
Heruntergeladen am 11.10.2025 von https://www.degruyterbrill.com/document/doi/10.1515/cclm.2011.779/html?lang=de
Button zum nach oben scrollen