Startseite Medizin Progress and impact of enzyme measurement standardization
Artikel
Lizenziert
Nicht lizenziert Erfordert eine Authentifizierung

Progress and impact of enzyme measurement standardization

  • Ilenia Infusino EMAIL logo , Erika Frusciante , Federica Braga und Mauro Panteghini
Veröffentlicht/Copyright: 8. Oktober 2016

Abstract

International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has established reference measurement procedures (RMPs) for the most popular enzymes. Manufacturers should assign values to commercial calibrators traceable to these RMPs to achieve equivalent results in clinical samples, independent of reagent kits, instruments, and laboratory where the measurement is carried out. The situation is, however, far from acceptable. Some manufacturers continue to market assays giving results that are not traceable to internationally accepted RMPs. Meanwhile, end-users often do not abandon assays with demonstrated insufficient quality. Of the enzyme measurements, creatine kinase (CK) is satisfactorily standardized and a substantial improvement in performance of marketed γ-glutamyltranspeptidase (GGT) assays has been demonstrated. Conversely, aminotransferase measurements often exceed the desirable analytical performance because of the lack of pyridoxal-5-phosphate addition in the commercial reagents. Measurements of lactate dehydrogenase (LDH), alkaline phosphatase (ALP), and α-amylase (AMY) still show major disagreement, suggesting the need for improvement in implementing traceability to higher-order references. This is mainly the result of using assays with different analytical selectivities for these enzymes. The definition by laboratory professionals of the clinically acceptable measurement uncertainty for each enzyme together with the adoption by EQAS of commutable materials and use of an evaluation approach based on trueness represent the way forward for reaching standardization in clinical enzymology.

Acknowledgments

The authors acknowledge the long cooperation and the fruitful discussion with Prof. Ferruccio Ceriotti, Chair of the IFCC Committee on Reference Systems in Enzymology.

  1. Author contributions: All the authors have accepted responsibility for the entire content of this submitted manuscript and approved submission.

  2. Research funding: None declared.

  3. Employment or leadership: None declared.

  4. Honorarium: None declared.

  5. Competing interests: The funding organization(s) played no role in the study design; in the collection, analysis, and interpretation of data; in the writing of the report; or in the decision to submit the report for publication.

References

1. Panteghini M, Bais R. Serum enzymes. In: Rifai N, Horvat AR, Wittwer C, editors. Tietz textbook of clinical chemistry and molecular diagnostics, 6th ed. St. Louis: Elsevier Saunders, 2016.Suche in Google Scholar

2. Ferraro S, Braga F, Panteghini M. Laboratory medicine in the new healthcare environment. Clin Chem Lab Med 2016;54:523–33.10.1515/cclm-2015-0803Suche in Google Scholar PubMed

3. Panteghini M. Traceability as a unique tool to improve standardization in laboratory medicine. Clin Biochem 2009;42:236–40.10.1016/j.clinbiochem.2008.09.098Suche in Google Scholar PubMed

4. Braga F, Panteghini M. Verification of in vitro medical diagnostics (IVD) metrological traceability: responsibilities and strategies. Clinica Chimica Acta 2014;432:55–61.10.1016/j.cca.2013.11.022Suche in Google Scholar PubMed

5. Infusino I, Bonora R, Panteghini M. Traceability in clinical enzymology. Clin Biochem Rev 2007;28:155-61.Suche in Google Scholar

6. Infusino I, Schumann G, Ceriotti F, Panteghini M. Standardization in clinical enzymology: a challenge for the theory of metrological traceability. Clin Chem Lab Med 2010;48:301–7.10.1515/CCLM.2010.075Suche in Google Scholar PubMed

7. Panteghini M. Implementation of standardization in clinical practice: not always an easy task. Clin Chem Lab Med 2012;50:1237–41.10.1515/cclm.2011.791Suche in Google Scholar PubMed

8. ISO 18153:2003. In vitro diagnostic medical devices – Measurement of quantities in biological samples – Metrological traceability of values for catalytic concentration of enzymes assigned to calibrators and control materials. ISO, Geneva, Switzerland.Suche in Google Scholar

9. Panteghini M, Ceriotti F, Schumann G, Siekmann L. Establishing a reference system in clinical enzymology. Clin Chem Lab Med 2001;39:795–800.10.1515/CCLM.2001.131Suche in Google Scholar PubMed

10. Frusciante E, Infusino I, Panteghini M. Stima dell’incertezza della misura della concentrazione di attività catalitica dell’alanina amminotransferasi (ALT) nel siero mediante il metodo di riferimento IFCC. Biochim Clin 2011;35:20–5.Suche in Google Scholar

11. Rami L, Canalias F. An approach to establish the uncertainty budget of catalytic activity concentration measurements in a reference laboratory. Clin Chem Lab Med 2015;53:743–51.10.1515/cclm-2014-0579Suche in Google Scholar PubMed

12. Schumann G, Bonora R, Ceriotti F, Clerc-Renaud P, Ferrero CA, Férard G, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 2. Reference procedure for the measurement of catalytic concentration of creatine kinase. Clin Chem Lab Med 2002;40:635–42.10.1515/CCLM.2002.110Suche in Google Scholar PubMed

13. Schumann G, Bonora R, Ceriotti F, Clerc-Renaud P, Ferrero CA, Férard G, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 3. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase. Clin Chem Lab Med 2002;40:643–8.10.1515/CCLM.2002.111Suche in Google Scholar PubMed

14. Schumann G, Bonora R, Ceriotti F, Férard G, Ferrero CA, Franck PF, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase. Clin Chem Lab Med 2002;40:718–24.10.1515/CCLM.2002.124Suche in Google Scholar PubMed

15. Schumann G, Bonora R, Ceriotti F, Férard G, Ferrero CA, Franck PF, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase. Clin Chem Lab Med 2002;40:725–33.10.1515/CCLM.2002.125Suche in Google Scholar

16. Schumann G, Bonora R, Ceriotti F, Férard G, Ferrero CA, Franck PF, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 6. Reference procedure for the measurement of catalytic concentration of γ-glutamyltransferase. Clin Chem Lab Med 2002;40:734–8.Suche in Google Scholar

17. Schumann G, Aoki R, Ferrero CA, Ehlers G, Férard G, Gella F-J, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C. Part 8. Reference procedure for the measurement of catalytic concentration of α-amylase. Clin Chem Lab Med 2006;44:1146–55.Suche in Google Scholar

18. Schumann G, Klauke R, Canalias F, Bossert-Reuther S, Franck PF, Gella F-J, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C. Part 9: Reference procedure for the measurement of catalytic concentration of alkaline phosphatase. Clin Chem Lab Med 2011;49:1439–46.10.1515/CCLM.2011.621Suche in Google Scholar

19. Jones GR, Jackson C. The Joint Committee for Traceability in Laboratory Medicine (JCTLM)-its history and operation. Clin Chim Acta 2016;453:86–94.10.1016/j.cca.2015.11.016Suche in Google Scholar

20. Toussaint B, Ceriotti F, Schimmel H, Rej R, Besozzi M, Gella FJ, et al. Commutability study on candidate materials for three new enzyme certified reference materials. Clin Chem Lab Med 2014;52:S1657.Suche in Google Scholar

21. Panteghini M, Ceriotti F. Obtaining reference intervals traceable to reference measurement systems: is it possible, who is responsible, what is the strategy? Clin Chem Lab Med 2012;50:813–7.10.1515/cclm.2011.828Suche in Google Scholar

22. Ceriotti F, Henny J, Queralto J, Ziyu S, Ozarda Y, Chen B, et al. Common reference intervals for aspartate aminotransferase (AST), alanine aminotransferase (ALT) and γ-glutamyltransferase (GGT) in serum: results from an IFCC multicenter. Clin Chem Lab Med 2010;48:1593–601.10.1515/CCLM.2010.315Suche in Google Scholar

23. Pagani F, Panteghini M. Reference interval for lactate dehydrogenase catalytic activity in serum measured according to the new IFCC recommendations. Clin Chem Lab Med 2003;41:970–1.10.1515/CCLM.2003.148Suche in Google Scholar

24. Schumann G, Klauke R. New IFCC reference procedures for the determination of catalytic activity concentrations of five enzymes in serum: preliminary upper reference limits obtained in hospitalized subjects. Clin Chim Acta 2003;327:69–79.10.1016/S0009-8981(02)00341-8Suche in Google Scholar

25. Ichihara K, Ceriotti F, Tam TH, Sueyoshi S, Poon PMK, Thong ML, et al. The Asian project for collaborative derivation of reference intervals: (1) strategy and major results of standardized analytes. Clin Chem Lab Med 2013;51:1429–42.10.1515/cclm-2012-0421Suche in Google Scholar PubMed

26. Han L, Wang J, Zhang Q, Ke P, Wu X, Wan Z, et al. Development of reference intervals for serum alkaline phosphatase among adults in Southern China traced to the new IFCC reference measurement procedure. Clin Chem Lab Med 2016;54:659–65.10.1515/cclm-2015-0732Suche in Google Scholar PubMed

27. Férard G, Piton A, Messous D, Imbert-Bismut F, Frairi A, Pyonard T, et al. Intermethod calibration of alanine aminotransferase (ALT) and γ-glutamyltransferase (GGT) results: application to Fibrotest and Actitest scores. Clin Chem Lab Med 2006;44:400–6.10.1515/CCLM.2006.078Suche in Google Scholar PubMed

28. Xia C, Tong Q, Wang Q, Tang Z, Qi L, Chi S, et al. Application of five frozen human-pooled serum samples assigned by the international federation of clinical chemistry and laboratory medicine reference procedure in a traceability investigation of gamma-glutamyltransferase catalytic concentration measurements in China. Ann Clin Biochem 2010;47:189–94.10.1258/acb.2009.009210Suche in Google Scholar PubMed

29. Dati F. The new European Directive on in vitro diagnostics. Clin Chem Lab Med 2003;41:1289–98.10.1515/CCLM.2003.196Suche in Google Scholar PubMed

30. Jansen R, Schumann G, Baadenhuijsen H, Franck P, Franzini C, Kruse R, et al. Trueness verification and traceability assessment of results from commercial systems for measurement of six enzyme activities in serum. An international study in the EC4 framework of the Calibration 2000 project. Clin Chim Acta 2006;368:160–7.10.1016/j.cca.2005.12.033Suche in Google Scholar PubMed

31. Jansen R, Jassam N, Thomas A, Perich C, Fernandez-Calle P, Faria AP, et al. A category 1 EQA scheme for comparison of laboratory performance and method performance: an international pilot study in the framework of the Calibration 2000 project. Clin Chim Acta 2014;432:90–8.10.1016/j.cca.2013.11.003Suche in Google Scholar PubMed

32. Goossens K, Van Uytfanghe K, Thienpont LM. Trueness and comparability assessment of widely used assays for 5 common enzymes and 3 electrolytes. Clin Chim Acta 2015;442:44–5.10.1016/j.cca.2015.01.009Suche in Google Scholar PubMed

33. Cattozzo G. Survey of analytical methods and result reporting for the measurement of catalytic activity of serum enzymes. Biochim Clin 2015;39:575-84.Suche in Google Scholar

34. Braga F, Frusciante E, Infusino I, Aloisio E, Guerra E, Ceriotti F, et al. Evaluation of the trueness of serum alkaline phosphatase measurement in a group of Italian laboratories. Clin Chem Lab Med 2016.10.1515/cclm-2016-0605Suche in Google Scholar PubMed

35. Panteghini M. Application of traceability concepts to analytical quality control may reconcile total error with uncertainty of measurement. Clin Chem Lab Med 2010;48:7–10.10.1515/CCLM.2010.020Suche in Google Scholar PubMed

36. Braga F, Infusino I, Panteghini M. Performance criteria for combined uncertainty budget in the implementation of metrological traceability. Clin Chem Lab Med 2015;53:905–12.10.1515/cclm-2014-1240Suche in Google Scholar PubMed

37. Miller WG, Jones GR, Horowitz GL, Weykamp C. Proficiency testing/external quality assessment: current challenges and future directions. Clin Chem 2011;57:1670–80.10.1373/clinchem.2011.168641Suche in Google Scholar PubMed

38. Ceriotti F. The role of external quality assessment Schemes in monitoring and improving the standardization process. Clin Chim Acta 2014;432:77–81.10.1016/j.cca.2013.12.032Suche in Google Scholar PubMed

39. Cobbaert C, Weykamp C, Franck P, de Jonge R, Kuypers A, Steigstra H, et al. Systematic monitoring of standardization and harmonization status with commutable EQA-samples – Five year experience from the Netherlands. Clin Chim Acta 2012;414:234–40.10.1016/j.cca.2012.09.027Suche in Google Scholar PubMed

40. Sandberg S, Fraser C, Horvath AR, Jansen R, Jones G, Oosterhuis W, et al. Defining analytical performance specifications: consensus statement from the 1st strategic conference of the European Federation of Clinical Chemistry and Laboratory Medicine. Clin Chem Lab Med 2015;53:833–5.10.1515/cclm-2015-0067Suche in Google Scholar PubMed

41. Ceriotti F, Fernandez-Calle P, Klee GG, Nordin G, Sandberg S, Streichert T, et al. Criteria for assigning laboratory measurands to models for analytical performance specifications defined in the 1st EFLM Strategic Conference. Clin Chem Lab Med 2017;55:189–94.10.1515/cclm-2017-0772Suche in Google Scholar PubMed

42. Carobene A, Braga F, Roraas T, Sandberg S, Bartlett WA. A systematic review of data on biological variation for alanine aminotransferase, aspartate aminotransferase and γ-glutamyl transferase. Clin Chem Lab Med 2013;51:1997–2007.10.1515/cclm-2013-0096Suche in Google Scholar PubMed

43. Bartlett WA, Braga F, Carobene A, Coşkun A, Prusa R, Fernandez-Calle P, et al. A checklist for critical appraisal of studies of biological variation. Clin Chem Lab Med 2015;53:879–85.10.1515/cclm-2014-1127Suche in Google Scholar PubMed

Received: 2016-7-25
Accepted: 2016-8-29
Published Online: 2016-10-8
Published in Print: 2017-3-1

©2017 Walter de Gruyter GmbH, Berlin/Boston

Artikel in diesem Heft

  1. Frontmatter
  2. Editorials
  3. Targeting errors in microbiology: the case of the Gram stain
  4. Time for a holistic approach and standardization education in laboratory medicine
  5. Reviews
  6. Serum uric acid levels and risk of prehypertension: a meta-analysis
  7. Lactic acidosis: an update
  8. Mini Review
  9. Progress and impact of enzyme measurement standardization
  10. Opinion Paper
  11. Critical comments to a recent EFLM recommendation for the review of reference intervals
  12. IFCC Paper
  13. Quality Indicators in Laboratory Medicine: the status of the progress of IFCC Working Group “Laboratory Errors and Patient Safety” project
  14. Genetics and Molecular Diagnostics
  15. Evaluation and comparison of three assays for molecular detection of spinal muscular atrophy
  16. General Clinical Chemistry and Laboratory Medicine
  17. Risk analysis of the preanalytical process based on quality indicators data
  18. Analytical and clinical validation of the new Abbot Architect 25(OH)D assay: fit for purpose?
  19. Looking beyond linear regression and Bland-Altman plots: a comparison of the clinical performance of 25-hydroxyvitamin D tests
  20. Next-generation osmotic gradient ektacytometry for the diagnosis of hereditary spherocytosis: interlaboratory method validation and experience
  21. Diagnosis of sphingolipidoses: a new simultaneous measurement of lysosphingolipids by LC-MS/MS
  22. Monitoring nicotine intake from e-cigarettes: measurement of parent drug and metabolites in oral fluid and plasma
  23. Development of a rapid and quantitative lateral flow assay for the simultaneous measurement of serum κ and λ immunoglobulin free light chains (FLC): inception of a new near-patient FLC screening tool
  24. A real-world evidence-based approach to laboratory reorganization using e-Valuate benchmarking data
  25. Cancer Diagnostics
  26. Utility of proGRP as a tumor marker in the medullary thyroid carcinoma
  27. Cardiovascular Diseases
  28. Can non-cholesterol sterols and lipoprotein subclasses distribution predict different patterns of cholesterol metabolism and statin therapy response?
  29. Infectious Diseases
  30. Improving Gram stain proficiency in hospital and satellite laboratories that do not have microbiology
  31. Diabetes
  32. Volumetric absorptive microsampling at home as an alternative tool for the monitoring of HbA1c in diabetes patients
  33. Corrigendum
  34. EFLM Recommendation
  35. Corrigendum to: Recommendation for the review of biological reference intervals in medical laboratories
  36. Letters to the Editor
  37. Evaluation of the trueness of serum alkaline phosphatase measurement in a group of Italian laboratories
  38. Innovative software for recording preanalytical errors in accord with the IFCC quality indicators
  39. Mixing studies for abnormal coagulation screen – the current trend
  40. Identification of 5-fluorocytosine as a new interfering compound in serum capillary zone electrophoresis
  41. How to define reference intervals to rule in healthy individuals for clinical trials?
  42. Evaluation of the performance of INDEXOR® in the archive unit of a clinical laboratory: a step to Lean laboratory
  43. Evaluation of an automated chemiluminescent immunoassay for salivary cortisol measurement. Utility in the diagnosis of Cushing’s syndrome
  44. Analysis of hemolysis, icterus and lipemia in arterial blood gas specimens
  45. Comparison of three routine insulin immunoassays: implications for assessment of insulin sensitivity and response
Heruntergeladen am 6.2.2026 von https://www.degruyterbrill.com/document/doi/10.1515/cclm-2016-0661/html?lang=de
Button zum nach oben scrollen