Multicentre physiological reference values for the concentration of creatininium in plasma and diagnostic specificity of glomerular filtration rate estimated with the MDRD equation

  • Xavier Fuentes-Arderiu , Virtudes Álvarez-Funes , Lluís Coca-Fábregas , Marta Cruz-Placer , Julián Díaz-Fernández , Pilar Herrero-Bernal , Francisca García-Caballero , María del Mar Larrea-Ortiz-Quintán , Pedro La-Torre-Marcellán , Carmen Mar-Medina , María Victoria Rodríguez-Hernández and Santiago Juvé-Cuxart
Published/Copyright: April 17, 2007
Become an author with De Gruyter Brill
Clinical Chemistry and Laboratory Medicine (CCLM)
From the journal Volume 45 Issue 4

Abstract

Background: The National Kidney Disease Education Program recommends that clinical laboratories, when asked for an estimation of glomerular filtration rate in a patient by means of the “four-variable” Modification of Diet in Renal Disease (MDRD) Study equation, also provide the measurement result for creatininium concentration in plasma and the appropriate reference interval. On the other hand, clinical laboratories seeking accreditation for compliance with ISO 15189:2003 need to demonstrate that the physiological reference intervals communicated to all users of laboratory services are appropriate for the patient population served, and for their measurement systems.

Methods: Ten clinical laboratories in different regions of Spain collaborated in identifying reference individuals and producing reference values for the concentration of creatininium in plasma using RD/Hitachi Modular Analytics analysers, and for the volume rate of glomerular filtrate in kidneys (glomerular filtration rate), estimated with the “four-variable” MDRD Study equation. All the logistic work was carried out in co-operation with the supplier of the reagents and analysers (Roche Diagnostics España, S.L., Sant Cugat del Vallès, Catalonia, Spain). Using all the reference values obtained by each laboratory, multicentre reference limits were estimated non-parametrically.

Results and conclusions: Reference intervals estimated in this study for concentrations of plasma creatininium are 52–85 μmol/L for women and 64–106 μmol/L for men. The diagnostic specificity of the estimated glomerular filtration rate is 99,2% when applied to healthy persons to screen for chronic kidney disease.

Clin Chem Lab Med 2007;45:531–4.


Corresponding author: Xavier Fuentes-Arderiu, Laboratori Clínic, IDIBELL—Hospital Universitari de Bellvitge, Feixa Llarga s/n, 08907 l'Hospitalet de Llobregat, Catalonia, Spain Fax: +33-93-2607546,

Received: 2006-12-18
Accepted: 2007-1-15
Published Online: 2007-04-17
Published in Print: 2007-04-01

©2007 by Walter de Gruyter Berlin New York

Articles in the same Issue

  1. Electrophoretic separations of cerebrospinal fluid proteins in clinical investigations
  2. Haemophilia A: molecular insights
  3. Quality specifications: self pleasure for clinical laboratories or added value for patient management?
  4. A724A polymorphism of sarco(endo)plasmic reticulum Ca2+-ATPase 2 (SERCA2) in hypertensive patients
  5. Associations of common polymorphisms in the thymidylate synthase, reduced folate carrier and 5-aminoimidazole-4-carboxamide ribonucleotide transformylase/inosine monophosphate cyclohydrolase genes with folate and homocysteine levels and venous thrombosis risk
  6. Pro12Ala polymorphism of the peroxisome proliferator-activated receptor-γ2 (PPARγ-2) gene is associated with greater insulin sensitivity and decreased risk of type 2 diabetes in an Iranian population
  7. A novel frameshift mutation of the lecithin:cholesterol acyltransferase (LCAT) gene associated with renal failure in familial LCAT deficiency
  8. The c.–292C>T promoter polymorphism increases reticulocyte-type 15-lipoxygenase-1 activity and could be atheroprotective
  9. The genetic polymorphisms of β3-adrenergic receptor (AR) Trp64Arg and β2-AR Gln27Glu are associated with obesity in Chinese male hypertensive patients
  10. Diagnostic performance of combined specific urinary proteins and urinary flow cytometry in urinary tract pathology
  11. Diagnostic accuracy of the FIDIS multiplex fluorescent microsphere immunodetection system for anti-extractable nuclear antigen (ENA) antibodies in connective tissue diseases
  12. Fluorimetric quantitation of citalopram and escitalopram in plasma: developing an express method to monitor compliance in clinical trials
  13. Free serum cortisol: quantification applying equilibrium dialysis or ultrafiltration and an automated immunoassay system
  14. Percutaneous coronary intervention-induced variations in systemic parameters of inflammation: relationship with the mode of stenting
  15. Multicentre physiological reference values for the concentration of creatininium in plasma and diagnostic specificity of glomerular filtration rate estimated with the MDRD equation
  16. Serum levels of ischemia-modified albumin in healthy volunteers after exercise-induced calf-muscle ischemia
  17. Reference intervals for follicle-stimulating hormone, luteinizing hormone and prolactin in children and young adults on the bioMérieux Mini-Vidas system
  18. Limits of usual biochemical alcohol markers in cord blood at term: a fetal/maternal population-based study
  19. Implementing the Stockholm Conference hierarchy of objective quality criteria in a routine laboratory
  20. The diffusion of innovations theory could help laboratorians in research translation
  21. Detection of CYP2D6 polymorphisms *9, *10, and *41 using ARMS-PCR and their allelic frequencies in 400 psychiatric patients
  22. Toward standardization of carbohydrate-deficient transferrin (CDT) measurements: I. Analyte definition and proposal of a candidate reference method
  23. Measurement of free thyroxine in laboratory medicine – proposal of measurand definition
Downloaded on 19.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2007.097/html
Scroll to top button