Home Thermoluminescent characteristics of nano-structure hydroxyapatite:Dy
Article
Licensed
Unlicensed Requires Authentication

Thermoluminescent characteristics of nano-structure hydroxyapatite:Dy

  • F. Ziaie , N. Farhadi Moein and M. Shafaei
Published/Copyright: December 18, 2014
Become an author with De Gruyter Brill

Abstract

The thermoluminescence response of Dysprosium doped hydroxyapatite samples with different mol percentage of 0.5, 1 and 2 were studied and compared with the pure hydroxyapatite. The samples were objected to 60Co gamma rays irradiation with doses of 100 mGy to 10 Gy. The main peak in the sample glow curves were obtained at 310 °C. The sensitivity of the 1 mol% Dy doped hydroxyapatite samples show the highest thermoluminescence response. Fading behavior of the irradiated samples was also studied. The experimental results show that the synthetic Dy-doped hydroxyapatite obtained by the hydrolysis method may be used in gamma radiation dosimetry.

Kurzfassung

Die Thermolumineszenzeigenschaften von Dysprosium dotierten Hydroxylapatit-Proben mit verschiedenen Mol-Prozenten von 0.5, 1 and 2 wurden untersucht und verglichen mit reinem Hydroxylapatit. Die Proben wurden mit 60Co Dosen von 100 mGy bis 10 Gy bestrahlt. Der Glowkurven-Hauptpeak der Probe wurde bei 310 °C erhalten. Die mit 1 mol% Dy dotierten Hydroxylapatit-Proben zeigen das höchste Ansprechvermögen. Das Fading-Verhalten der bestrahlten Proben wurde ebenfalls untersucht. Die experimentellen Ergebnisse zeigen, dass das mittels der Hydrolysemethode erhaltene synthetische Dy-dotierte Hydroxylapatit in der Gammastrahlendosimetrie verwendet werden kann.

References

1 Brady, J. M.; Aarestad, N. O.; Swarts, H. M.: In vivo dosimetry by electron spin resonance spectroscopy. Med. Phys.15 (1968) 4347Search in Google Scholar

2 Ziaie, F.; Hajiloo, N.; Fathollahi, H.; Mehtieva, S. I.: Bone powder as EPR dosimetry system for electron and gamma radiation. NUKLEONIKA54 (2009) 267270Search in Google Scholar

3 Ziaie, F.; Stachowicz, W.; Strzelczak, G.; Al-Osaimi, S.: Using bone powder for dosimetric system EPR response under the action of gamma irradiation. Nukleonika4 (1999) 603608Search in Google Scholar

4 International Atomic Energy Agency. Use of electron paramagnetic resonance dosimetry with tooth enamel for retrospective dose assessment. TECDOC-1331, IAEA (2002)Search in Google Scholar

5 Driessens, F. C. M.: The mineral in bone, dentine and tooth enamel. Bull. Soc. Chem. Belgrade89 (1980) 66368910.1002/bscb.19800890811Search in Google Scholar

6 Oliveira, L. M.; Rossi, A. M.; Lopes, R. T.: Gamma dose response of synthetic A-type carbonated apatite in comparison with the response of tooth enamel. Appl. Radiat. Isot.52 (2000) 1093109710.1016/S0969-8043(00)00045-2Search in Google Scholar

7 Seshagiri, T. K.; Natarajan, V.; Sastry, M. D.: 1992 Thermoluminescence and its applications. (Eds.) K. V. R.Murthy et al. (New Delhi: Tata McGraw-Hill) Welker T. 1991 J. Lumin. 4849 49Search in Google Scholar

8 Jen Shih, W.; Feng Chen, Y.; Chin Wang, M.; Hsiung Hon, M.: Crystal growth and morphology of the nano-sized hydroxyapatite powders synthesized from CaHPO4–2H2O and CaCO3 by hydrolysis method. J. Crystal Growth270 (2004) 21121810.1016/j.jcrysgro.2004.06.023Search in Google Scholar

9 Solaimani, F.; Zahmatkesh, M. H.; Akhlaghpoor, Sh.: Dental tissue as a TLD dosimeter. Iran J. Radiat. Res1 (2003) 113117Search in Google Scholar

Received: 2014-08-16
Published Online: 2014-12-18
Published in Print: 2014-12-18

© 2014, Carl Hanser Verlag, München

Downloaded on 28.10.2025 from https://www.degruyterbrill.com/document/doi/10.3139/124.110445/html
Scroll to top button