Startseite A new Iodobismuthate Method with a Low Volume Filtration Device as a New Tool for the Determination of Microgram Oxyethylate Amounts
Artikel
Lizenziert
Nicht lizenziert Erfordert eine Authentifizierung

A new Iodobismuthate Method with a Low Volume Filtration Device as a New Tool for the Determination of Microgram Oxyethylate Amounts

  • Bogdan Wyrwas und Agnieszka Zgoła-Grześkowiak
Veröffentlicht/Copyright: 13. Mai 2015
Veröffentlichen auch Sie bei De Gruyter Brill

Abstract

The standard procedure of non-ionic surfactant detection by using the Bismuth Active Substances method offers low sensitivity, precision and a high consumption of the reagents. A new spectrophotometric (λmax = 460 nm of the visible spectrum) iodobismuthate method was developed, which may be successfully used to determine the presence of non-ionic surfactants at microgram levels. The oxyethylates were precipitated with the modified Dragendorff reagent, filtered, dissolved and afterwards the spectrophotometric determination of the equivalent bismuth amount was carried out. Several key factors, which influence the results of the proposed oxyethylate determination method, were optimized. The consumption of chemical reagents was notably decreased and the sensitivity of the method increased significantly in comparison to the standard method of non-ionic surfactant determination.

Kurzfassung

Die Standardmethode zur Bestimmung von nichtionischen Tensiden mittels bismutaktiver Substanzen ist gekennzeichnet von einer geringen Empfindlichkeit und Genauigkeit sowie von einem hohen Verbrauch an Reagenzien. Eine neue spektrophotometrische Iodbismutat-Methode (λmax = 460 nm des sichtbaren Spektrums) wurde entwickelt. Mit ihr wurden nicht-ionische Tenside im Mikrogrammbereich bestimmt. Die Oxyethylate wurden mit dem modifizierten Dargendroff-Reagenz ausgefällt, dann filtiert und wieder aufgelöst. Daran schloss sich die spektrophotometrische Bestimmung des Bismutäquivalents an. Es wurden verschiedene Schlüsselfaktoren, die die Ergebnisse der vorgeschlagenen Methode beeinflussten, optimiert. Im Vergleich zu der Standardbestimmungsmethode für nicht-ionische Tenside wurde der Verbrauch an Chemikalien erheblich verringert und die Empfindlichkeit der Methode deutlich erhöht.


* Correspondence address, Prof. Dr Bogdan Wyrwas, Institute of Chemistry and Technical Electrochemistry Poznan University of Technology, Piotrowo 3, 60-965 Poznań, Poland, E-Mail:

Bogdan Wyrwas received his Ph.D. in chemistry from Poznan University of Technology in 1997. He was graduated with Dr. degree at Poznan University of Technology in 2013 and he works there as an assistant professor. His research is focused on analysis and biodegradarion of surfactants.

Agnieszka Zgoła-Grześkowiak received her Ph.D. in chemistry from Poznan University of Technology in 2003 and she works there as an assistant professor. Her main research interests are biodegradation of surfactants and modern sample preparation techniques in environmental analysis.


References

1. Němcová, I., Tománková, V. and Rychlovský, P.: Talanta52 (2000) 111121. 10.1016/S0039-9140(99)00360-4Suche in Google Scholar

2. Martínez-Barrachina, S., del Valle, M., Matia, L., Prats, R. and AlonsoJ.: Anal. Chim. Acta438 (2001) 305313. 10.1016/S0003-2670(00)01342-8Suche in Google Scholar

3. Zhu, Z., Li, Z., Hao, Z. and Chen, J.: Wat. Res.37 (2003) 45064512. 10.1016/S0043-1354(03)00379-8Suche in Google Scholar

4. Sak-Bosnar, M., Madunić-Čačić, D., Sakač, N., Galović, O., Samardžić, M. and Grabarić, Z.: Electrochim. Acta55 (2009) 528534. 10.1016/j.electacta.2009.09.010Suche in Google Scholar

5. Wickbold, R.Die Analytik der Tenside, Red., Hüls, Marl (1977).Suche in Google Scholar

6. Brown, D., De Henau, H., Garrigan, J. T., Gerike, P., Holt, M., Keck, E., Kunkel, E., Matthijs, E., Waters, J. and Watkinson, R. J.: Tenside Det. 23 (1986) 190195.10.1515/tsd-1986-230414Suche in Google Scholar

7. Jia, Z. and Tian, C.: Desalination247 (2009) 423429. 10.1016/j.desal.2008.09.004Suche in Google Scholar

8. Wyrwas, B., Szymański, A. and Łukaszewski, Z.: Anal. Chim. Acta278 (1993) 197203. 10.1016/0003-2670(93)80097-5Suche in Google Scholar

9. Wyrwas, B., Szymański, A. and Łukaszewski, Z.: Talanta41 (1994) 15291535. 10.1016/0039-9140(94)E0063-WSuche in Google Scholar

10. Wyrwas, B., Szymański, A. and Łukaszewski, Z.: Talanta42 (1995) 12511258. 10.1016/0039-9140(95)01568-VSuche in Google Scholar

11. Łukaszewski, Z., Szymanski, A. and Wyrwas, B.: Trends Anal. Chem.15 (1996) 525531. 10.1016/S0165-9936(96)00064-7Suche in Google Scholar

12. Morchało, J., Rydlichowski, R., Szymański, A., Wyrwas, B. and Łukaszewski, Z.: Anal. Chim. Acta540 (2005) 915. 10.1016/j.aca.2004.10.081Suche in Google Scholar

13. Guidance for Industry, Q2B Validation of Analytical Procedures: Methodology, November 1996, ICH.Suche in Google Scholar

14. Moldoveanu, M., Rău, I., Fleancu, M., Mihaly, M.: U.P.B. Sci. Bull., Series B73 (2011) 4154.Suche in Google Scholar

15. Tan, B. L. L. and Mustafa, A. M.: Asia Pac. J. Public Health16 (2004) 5463. 10.1177/101053950401600110Suche in Google Scholar PubMed

16. DeArmond, P. D. and DiGoregorio, A. L.: J. Chromatogr. A1305 (2013) 154163. 10.1016/j.chroma.2013.07.017Suche in Google Scholar PubMed

17. Wyrwas, B., Dymaczewski, Z., Zgoła-Grześkowiak, A., Szymański, A., Frańska, M., Kruszelnicka, I., Ginter-Kramarczyk, D., Cyplik, P., Ławniczak, Ł. and Chrzanowski, Ł.: J. Environ. Manage.128 (2013) 292299. 10.1016/j.jenvman.2013.05.028Suche in Google Scholar PubMed

18. Zgoła-Grześkowiak, A., Grześkowiak, T., Rydlichowski, R., Hołderna-Odachowska, A., and Łukaszewski, Z.: J. Chromatogr. Sci.49 (2011) 4650. 10.1093/chrsci/49.1.46Suche in Google Scholar

Received: 2014-08-04
Accepted: 2015-02-10
Published Online: 2015-05-13
Published in Print: 2015-05-15

© 2015, Carl Hanser Publisher, Munich

Heruntergeladen am 9.10.2025 von https://www.degruyterbrill.com/document/doi/10.3139/113.110368/html
Button zum nach oben scrollen