Startseite Technik Transient performance during stopping the research reactor primary loop pump
Artikel
Lizenziert
Nicht lizenziert Erfordert eine Authentifizierung

Transient performance during stopping the research reactor primary loop pump

  • H. Akbarian Shourkaei
Veröffentlicht/Copyright: 21. März 2015
Veröffentlichen auch Sie bei De Gruyter Brill

Abstract

In this work an attempt is made to achieve characteristics curves for the Tehran Research Reactor (TRR) during stopping. The TRR pump speed during the event is time dependent. This is done for the TRR first quadrant operating characteristics. The obtained results indicate that the time needed for the coolant flow rate to reach zero is greater than the time necessary for the pump to come to complete stoppage.

Kurzfassung

In diesem Beitrag werden die charakteristischen Kurven während des Abschaltvorgangs für den Teheraner Forschungsreaktor (TRR) bestimmt. Die Pumpengeschwindigkeit des TRR ist während dieses Vorgangs zeitabhängig. Die Bestimmung erfolgt für die Betriebscharakteristik des ersten Quadranten. Die erhaltenen Ergebnisse zeigen, dass die Zeitspanne, um die Strömungsgeschwindigkeit des Kühlmittels auf Null zu bringen, größer ist als die Zeit, die die Pumpe zum vollständigen Stillstand benötigt.

References

1 Knapp, R. T.: Complete Characteristics of centrifugal pumps and their use in the prediction of transient behaviour. Trans. ASME59 (1937) 638689Suche in Google Scholar

2 Kaneko, M.; Ohashi, H.: Transient characteristics of a centrifugal pump during quik change of flow rate. Trans. JSME, Ser. B48 (1982) 229237 (in Japanese).10.1299/kikaib.48.229Suche in Google Scholar

3 Tsukamoto, H.; Ohashi, H.: Transient characteristics of a centrifugal pump during starting period. ASME Journal of Fluids Engineering104 (1982) 61410.1115/1.3240843Suche in Google Scholar

4 Saito, S.: The transient characteristics of a pump during start up. Bulletin of JSME25 (1983) 37237910.1299/jsme1958.25.372Suche in Google Scholar

5 Farhadi, K.; Shourkaei, H. Akbarian: Flow transient's performance in an MTR-type research reactor, submitted to Progress in Nuclear Energy, 201010.1016/j.pnucene.2010.01.004Suche in Google Scholar

6 Farhadi, K.; Shourkaei, H. Akbarian: Transient behaviour of parallel pump in nuclear research reacotors, submitted to Progress in Nuclear Energy, 2010Suche in Google Scholar

7 Arker, A. J.; Lewis, D. G.: Rapid flow transients in closed loops. In: Reactor Heat Transfer Conference of 1956. TID-7529 (part 1), Book 1, pp. 3347Suche in Google Scholar

8 Yokomura, T.: Flow coastdown in centrifugal pump system. Nuclear Engineering and Design10 (1969) 25025810.1016/0029-5493(69)90044-2Suche in Google Scholar

9 Grover, R. B.; Koranne, S. M.: Analysis of pump start-up in transients. Nuclear Engineering and Design6 (1981) 13714410.1016/0029-5493(81)90161-8Suche in Google Scholar

10 McAdams, W. H.: Heat Transmission, 1954, 3rd Ed. McGraw-Hill, New York, NYSuche in Google Scholar

11 IAEA-TECDOC-233,1980.IAEA: Research Reactor Core Conversion from the Use of High-Enriched Uranium to the Use of Low Enriched Uranium Fuels GuidebookSuche in Google Scholar

12 Emanuel, P.: Motors, Generators, Transformers, and Energy, Englewood Cliffs, Prentice-Hall, 1985Suche in Google Scholar

13 ArunimaDey; et al.: An Improved Model of a Three phase Induction Motor Incorporating the Parameter Variations, Electrical Power Quality and Utilisation, Journal Vol. XIV, No. 1, 2008Suche in Google Scholar

Received: 2014-10-14
Published Online: 2015-03-21
Published in Print: 2015-03-17

© 2015, Carl Hanser Verlag, München

Heruntergeladen am 11.12.2025 von https://www.degruyterbrill.com/document/doi/10.3139/124.110476/html
Button zum nach oben scrollen