Abstract
Background: Circulating cell-free (ccf) DNA in blood has been suggested as a potential biomarker in many conditions regarding early diagnosis and prognosis. However, misdiagnosis can result due to the limited DNA resources in Biobank’s plasma samples or insufficient DNA targets from a predominant DNA background in genetic tests. This study explored several strategies for an efficient DNA extraction to increase DNA amount from limited plasma input.
Methods: Ccf plasma DNA was extracted with three different methods, a phenol-chloroform-isoamylalcohol (PCI) method, a High Pure PCR Template Preparation Kit method and a method used for single cell PCR in this group. Subsequently, the total DNA was measured by Nanodrop and the genome equivalents (GE) of the GAPDH housekeeping gene and MTATP 8 gene were measured using a multiplex real-time quantitative PCR for the quantitative assessment of nDNA and mtDNA.
Results: Instead of 400–800 μL (routine input in the laboratory), 50 μLof plasma input enabled the extraction of ccf DNA sufficient for quantitative analysis. Using the PCI method and the kit method, both nDNA and mtDNA could be successfully detected in plasma samples, but nDNA extracted using protocol for single cell PCR was not detectable in 25% of plasma samples. In comparison to the other two methods, the PCI method showed lower DNA purity, but higher concentrations and more GE of nDNA and mtDNA.
Conclusions: The PCI method was more efficient than the other two methods in the extraction of ccf DNA in plasma. Limited plasma is available for ccf DNA analysis.
©2012 by Walter de Gruyter Berlin Boston
Articles in the same Issue
- Editorials
- Biological variation and reference change values: an essential piece of the puzzle of laboratory testing
- Copeptin for acute coronary syndrome: diamond or decoy?
- Reviews
- Gold nanoparticles in the clinical laboratory: principles of preparation and applications
- The physiology and pathobiology of human kallikrein-related peptidase 6 (KLK6)
- Mini Review
- From “Clinical Proteomics” to “Clinical Chemistry Proteomics”: considerations using quantitative mass-spectrometry as a model approach
- Opinion Paper
- Considerations for early acute myocardial infarction rule-out for emergency department chest pain patients: the case of copeptin
- Perspectives
- Do genome-wide association scans have potential for translation?
- Genetics and Molecular Diagnostics
- Strategies of reducing input sample volume for extracting circulating cell-free nuclear DNA and mitochondrial DNA in plasma
- Evaluation of Maxwell® 16 for automated DNA extraction from whole blood and formalin-fixed paraffin embedded (FFPE) tissue
- Screening for mutations in the α-globin genes leading to abnormal hemoglobin variants with high resolution melting analysis
- Alternative methods to a TaqMan assay to detect a tri-allelic single nucleotide polymorphism rs757210 in the HNF1β gene
- Gender- and obesity-specific effect of apolipoprotein C3 gene (APOC3) –482C>T polymorphism on triglyceride concentration in Turkish adults
- Angiotensin converting enzyme (ACE) insertion/deletion (I/D) polymorphism and circulating ACE levels are not associated with outcome in critically ill septic patients
- Detection of internal tandem duplications in the FLT3 gene by different electrophoretic methods
- Functional polymorphisms of GSTA1 and GSTO2 genes associated with asthma in Italian children
- General Clinical Chemistry and Laboratory Medicine
- Optimisation of whole blood and plasma manganese assay by ICP-MS without use of a collision cell
- Quantitative performance of antibody array technology in a prenatal screening setting
- A comparison of the acute effects of calcium and strontium ranelate on the serum marker of bone resorption
- A new dot immunoassay for simultaneous detection of celiac specific antibodies and IgA-deficiency
- Preferentially immunoglobulin (IgG) subclasses production in primary Sjögren’s syndrome patients
- Development of control material for hemoglobin analysis
- Evaluation of nucleated red blood cells in the peripheral blood of hematological diseases
- The effect of hematocrit on the results of measurements using glucose meters based on different techniques
- Lupus anticoagulant testing: analyzing fresh samples after a single centrifugation and after a 6–8 h delay
- Pseudoeosinophilia of synovial fluid is caused by crystals mimicking the distinct light scattering fractions of eosinophilic granules
- The effect of acidification and oxalate concentration on urine calcium measurements in EQAS materials and patient samples
- Cancer Diagnostics
- The multi-cancer marker, rs6983267, located at region 3 of chromosome 8q24, is associated with prostate cancer in Greek patients but does not contribute to the aggressiveness of the disease
- Cardiovascular Diseases
- Heart type fatty acid binding protein in relation to pharmacologic scintigraphy in coronary artery disease
- Effects of fibrates on C-reactive protein concentrations: a meta-analysis of randomized controlled trials
- Letters to the Editor
- Comparison of Bio-Plex measurements with standard techniques
- Interference of hemoglobin (Hb) Las Palmas with HPLC measurement of HbA1c in 87 patients
- False-positive calcitonin results in patients with benign goiter
- Erratum
- Heterophilic antibody interference in commercial immunoassays; a screening study using paired native and pre-blocked sera
- Congress Abstracts
- Advances and Controversies in B-Vitamins and Choline
- Prelims
Articles in the same Issue
- Editorials
- Biological variation and reference change values: an essential piece of the puzzle of laboratory testing
- Copeptin for acute coronary syndrome: diamond or decoy?
- Reviews
- Gold nanoparticles in the clinical laboratory: principles of preparation and applications
- The physiology and pathobiology of human kallikrein-related peptidase 6 (KLK6)
- Mini Review
- From “Clinical Proteomics” to “Clinical Chemistry Proteomics”: considerations using quantitative mass-spectrometry as a model approach
- Opinion Paper
- Considerations for early acute myocardial infarction rule-out for emergency department chest pain patients: the case of copeptin
- Perspectives
- Do genome-wide association scans have potential for translation?
- Genetics and Molecular Diagnostics
- Strategies of reducing input sample volume for extracting circulating cell-free nuclear DNA and mitochondrial DNA in plasma
- Evaluation of Maxwell® 16 for automated DNA extraction from whole blood and formalin-fixed paraffin embedded (FFPE) tissue
- Screening for mutations in the α-globin genes leading to abnormal hemoglobin variants with high resolution melting analysis
- Alternative methods to a TaqMan assay to detect a tri-allelic single nucleotide polymorphism rs757210 in the HNF1β gene
- Gender- and obesity-specific effect of apolipoprotein C3 gene (APOC3) –482C>T polymorphism on triglyceride concentration in Turkish adults
- Angiotensin converting enzyme (ACE) insertion/deletion (I/D) polymorphism and circulating ACE levels are not associated with outcome in critically ill septic patients
- Detection of internal tandem duplications in the FLT3 gene by different electrophoretic methods
- Functional polymorphisms of GSTA1 and GSTO2 genes associated with asthma in Italian children
- General Clinical Chemistry and Laboratory Medicine
- Optimisation of whole blood and plasma manganese assay by ICP-MS without use of a collision cell
- Quantitative performance of antibody array technology in a prenatal screening setting
- A comparison of the acute effects of calcium and strontium ranelate on the serum marker of bone resorption
- A new dot immunoassay for simultaneous detection of celiac specific antibodies and IgA-deficiency
- Preferentially immunoglobulin (IgG) subclasses production in primary Sjögren’s syndrome patients
- Development of control material for hemoglobin analysis
- Evaluation of nucleated red blood cells in the peripheral blood of hematological diseases
- The effect of hematocrit on the results of measurements using glucose meters based on different techniques
- Lupus anticoagulant testing: analyzing fresh samples after a single centrifugation and after a 6–8 h delay
- Pseudoeosinophilia of synovial fluid is caused by crystals mimicking the distinct light scattering fractions of eosinophilic granules
- The effect of acidification and oxalate concentration on urine calcium measurements in EQAS materials and patient samples
- Cancer Diagnostics
- The multi-cancer marker, rs6983267, located at region 3 of chromosome 8q24, is associated with prostate cancer in Greek patients but does not contribute to the aggressiveness of the disease
- Cardiovascular Diseases
- Heart type fatty acid binding protein in relation to pharmacologic scintigraphy in coronary artery disease
- Effects of fibrates on C-reactive protein concentrations: a meta-analysis of randomized controlled trials
- Letters to the Editor
- Comparison of Bio-Plex measurements with standard techniques
- Interference of hemoglobin (Hb) Las Palmas with HPLC measurement of HbA1c in 87 patients
- False-positive calcitonin results in patients with benign goiter
- Erratum
- Heterophilic antibody interference in commercial immunoassays; a screening study using paired native and pre-blocked sera
- Congress Abstracts
- Advances and Controversies in B-Vitamins and Choline
- Prelims