Home Medicine Pseudoeosinophilia of synovial fluid is caused by crystals mimicking the distinct light scattering fractions of eosinophilic granules
Article
Licensed
Unlicensed Requires Authentication

Pseudoeosinophilia of synovial fluid is caused by crystals mimicking the distinct light scattering fractions of eosinophilic granules

  • Christoph Robier EMAIL logo , Franz Quehenberger , Manfred Neubauer , Mariana Stettin and Franz Rainer
Published/Copyright: October 11, 2011

Abstract

Background: Automated leukocyte differential counts of synovial fluid (SF) can be influenced by laboratory artefacts. Pseudoeosinophilia of SF has recently been first described in association with monosodium urate and calcium pyrophosphate crystals. This study compared automated measurements of the percentages of SF leukocyte fractions by two haematology analysers in order to elucidate the underlying mechanism of pseudoeosinophilia.

Methods: The percentages of the leukocyte fractions of 17 crystal-containing and 28 crystal-free specimens were compared using the Wilcoxon test. Measurements were performed using the Cell-Dyn 3200 and the ADVIA 2120i, which are based on different techniques.

Results: The percentages of eosinophils of the crystal-positive samples determined by the Cell-Dyn 3200 were significantly higher than those assessed by the ADVIA (p<0.0001), whereas the percentages of eosinophils of the controls did not differ significantly between the two devices (p=0.95). The Cell-Dyn 3200 clearly showed the phenomenon of crystal-associated pseudoeosinophilia (p<0.0001), which did not occur in the ADVIA measurements (p=0.28). The percentage of neutrophils was to a lower degree elevated in the crystal group (p=0.015).

Conclusions: It was confirmed that SF crystals interfere with the typical light scattering fractions of leukocyte granules and may thus lead to spuriously elevated percentages of eosinophils and neutrophils in SF specimens.


Corresponding author: Christoph Robier, MD, Central Laboratory, Department of Internal Medicine, Hospital Barmherzige Brueder, Graz-Eggenberg, Bergstrasse 27, 8020 Graz, Austria Phone: +43 316 5989 6671

Received: 2011-8-2
Accepted: 2011-9-20
Published Online: 2011-10-11
Published in Print: 2012-02-01

©2012 by Walter de Gruyter Berlin Boston

Articles in the same Issue

  1. Editorials
  2. Biological variation and reference change values: an essential piece of the puzzle of laboratory testing
  3. Copeptin for acute coronary syndrome: diamond or decoy?
  4. Reviews
  5. Gold nanoparticles in the clinical laboratory: principles of preparation and applications
  6. The physiology and pathobiology of human kallikrein-related peptidase 6 (KLK6)
  7. Mini Review
  8. From “Clinical Proteomics” to “Clinical Chemistry Proteomics”: considerations using quantitative mass-spectrometry as a model approach
  9. Opinion Paper
  10. Considerations for early acute myocardial infarction rule-out for emergency department chest pain patients: the case of copeptin
  11. Perspectives
  12. Do genome-wide association scans have potential for translation?
  13. Genetics and Molecular Diagnostics
  14. Strategies of reducing input sample volume for extracting circulating cell-free nuclear DNA and mitochondrial DNA in plasma
  15. Evaluation of Maxwell® 16 for automated DNA extraction from whole blood and formalin-fixed paraffin embedded (FFPE) tissue
  16. Screening for mutations in the α-globin genes leading to abnormal hemoglobin variants with high resolution melting analysis
  17. Alternative methods to a TaqMan assay to detect a tri-allelic single nucleotide polymorphism rs757210 in the HNF1β gene
  18. Gender- and obesity-specific effect of apolipoprotein C3 gene (APOC3) –482C>T polymorphism on triglyceride concentration in Turkish adults
  19. Angiotensin converting enzyme (ACE) insertion/deletion (I/D) polymorphism and circulating ACE levels are not associated with outcome in critically ill septic patients
  20. Detection of internal tandem duplications in the FLT3 gene by different electrophoretic methods
  21. Functional polymorphisms of GSTA1 and GSTO2 genes associated with asthma in Italian children
  22. General Clinical Chemistry and Laboratory Medicine
  23. Optimisation of whole blood and plasma manganese assay by ICP-MS without use of a collision cell
  24. Quantitative performance of antibody array technology in a prenatal screening setting
  25. A comparison of the acute effects of calcium and strontium ranelate on the serum marker of bone resorption
  26. A new dot immunoassay for simultaneous detection of celiac specific antibodies and IgA-deficiency
  27. Preferentially immunoglobulin (IgG) subclasses production in primary Sjögren’s syndrome patients
  28. Development of control material for hemoglobin analysis
  29. Evaluation of nucleated red blood cells in the peripheral blood of hematological diseases
  30. The effect of hematocrit on the results of measurements using glucose meters based on different techniques
  31. Lupus anticoagulant testing: analyzing fresh samples after a single centrifugation and after a 6–8 h delay
  32. Pseudoeosinophilia of synovial fluid is caused by crystals mimicking the distinct light scattering fractions of eosinophilic granules
  33. The effect of acidification and oxalate concentration on urine calcium measurements in EQAS materials and patient samples
  34. Cancer Diagnostics
  35. The multi-cancer marker, rs6983267, located at region 3 of chromosome 8q24, is associated with prostate cancer in Greek patients but does not contribute to the aggressiveness of the disease
  36. Cardiovascular Diseases
  37. Heart type fatty acid binding protein in relation to pharmacologic scintigraphy in coronary artery disease
  38. Effects of fibrates on C-reactive protein concentrations: a meta-analysis of randomized controlled trials
  39. Letters to the Editor
  40. Comparison of Bio-Plex measurements with standard techniques
  41. Interference of hemoglobin (Hb) Las Palmas with HPLC measurement of HbA1c in 87 patients
  42. False-positive calcitonin results in patients with benign goiter
  43. Erratum
  44. Heterophilic antibody interference in commercial immunoassays; a screening study using paired native and pre-blocked sera
  45. Congress Abstracts
  46. Advances and Controversies in B-Vitamins and Choline
  47. Prelims
Downloaded on 15.2.2026 from https://www.degruyterbrill.com/document/doi/10.1515/cclm.2011.745/html
Scroll to top button