Biomechanical finite element analysis of small diameter and short dental implant
-
Istabrak Hasan
, Friedhelm Heinemann , Maria Aitlahrach und Christoph Bourauel
Abstract
Short and mini dental implants have been widely used as treatment alternatives in certain selected clinical situations. However, a profound scientific analysis of the mechanical and biomechanical impact of the reduced length and diameter of these implant geometries has not been published until now. Using finite element analysis, a series of different experimentally designed short and mini implants have been analysed with regard to their load transfer to the alveolar bone and have been compared to respective standard commercial implants. Mini implants have been inserted in an idealised bone bed representing the anterior mandibular jaw region and loaded with a force of 150 N. An immediate loading condition was assumed and analysed using the contact analysis option of the FE package MSC.Marc/Mentat. Short implants were inserted in an idealised posterior bone segment and loaded in osseointegrated state with forces of 300 N. Clearly increased bone loading was observed for the short and mini dental implants compared with standard implants, clearly exceeding the physiological limit of 100 MPa. The determined biomechanical characteristics could explain the slightly increased failure rate of short and mini dental implants.
©2010 by Walter de Gruyter Berlin New York
Artikel in diesem Heft
- Guest editorial
- Aspects of oral and dental reconstitution with dental implants and membranes
- Review
- Clinical, biomechanical and biological aspects of immediately loaded dental implants: a critical review of the literature
- Research articles
- Crestal bone resorption around platform-switched dental implants with fine threaded neck after immediate and delayed loading
- The influence of biocomposites containing genetically modified flax fibers on gene expression in rat skeletal muscle
- Use of primary culture of human fibroblasts in gingiva augmentation procedure
- Retention force of secondary crowns to copings after temporary cementation: the effect of crown material and luting agent
- Biomechanical finite element analysis of small diameter and short dental implant
- Original articles
- Systematic user-based assessment of “Navigated Control Spine” / Systematische, nutzerzentrierte Evaluation von „Navigated Control Spine”
- Influence of formalin fixation on the biomechanical properties of human diaphyseal bone
- Asynchronous steady-state visual evoked potential based BCI control of a 2-DoF artificial upper limb
Artikel in diesem Heft
- Guest editorial
- Aspects of oral and dental reconstitution with dental implants and membranes
- Review
- Clinical, biomechanical and biological aspects of immediately loaded dental implants: a critical review of the literature
- Research articles
- Crestal bone resorption around platform-switched dental implants with fine threaded neck after immediate and delayed loading
- The influence of biocomposites containing genetically modified flax fibers on gene expression in rat skeletal muscle
- Use of primary culture of human fibroblasts in gingiva augmentation procedure
- Retention force of secondary crowns to copings after temporary cementation: the effect of crown material and luting agent
- Biomechanical finite element analysis of small diameter and short dental implant
- Original articles
- Systematic user-based assessment of “Navigated Control Spine” / Systematische, nutzerzentrierte Evaluation von „Navigated Control Spine”
- Influence of formalin fixation on the biomechanical properties of human diaphyseal bone
- Asynchronous steady-state visual evoked potential based BCI control of a 2-DoF artificial upper limb