Home Evaluation of Commutability of Control Materials
Article
Licensed
Unlicensed Requires Authentication

Evaluation of Commutability of Control Materials

  • Emmanuel Brion , Jean-Marc Lessinger , Nicholas Gould , Jacky Leyendecker and Georges Férard
Published/Copyright: June 1, 2005
Become an author with De Gruyter Brill
Clinical Chemistry and Laboratory Medicine (CCLM)
From the journal Volume 40 Issue 6

Abstract

The commutability of 13 control materials was evaluated by performing parallel measurements on two different analysers: a Synchron CX-5 Delta from Beckman-Coulter and a Vitros 950 from Ortho-Clinical Diagnostics. Twenty three clinical chemistry analytes (substrates, electrolytes and enzymatic activities) were determined in plasma from 15 different patients in order to define intermethod relationship for each analyte. The relationship observed for each control material was compared to those obtained for patients' specimens. The results show that commutability depends both on the tested analyte and on the control material. No totally commutable material has been found for the whole set of tested parameters. Most control materials were commutable for inorganic phosphate, glucose, chloride, triglycerides, alanine aminotransferase, amylase and γ-glutamyltransferase, but less than a quarter of control materials were commutable for sodium, calcium, creatinine, alkaline phosphatase and lipase. Seven materials were commutable for more than half of the analytes, whereas five control materials were commutable for less than a quarter of these analytes. We propose to verify the commutability of materials before their use in an external quality control assessement.

:
Published Online: 2005-06-01
Published in Print: 2002-06-21

Copyright © 2002 by Walter de Gruyter GmbH & Co. KG

Articles in the same Issue

  1. IFCC Primary Reference Procedures for the Measurement of Catalytic Concentrations of Enzymes – the New Concept
  2. Allele Frequency of the G→T Mutation of the Col1A1 Gene Analyzed by an ARMS-PCR in Osteoporotic Subjects with Femoral Neck Fractures
  3. Vitamin Supplementation Normalizes Total Plasma Homocysteine Concentration but Not Plasma Homocysteine Redox Status in Patients with Acute Coronary Syndromes and Hyperhomocysteinemia
  4. Mutation Analysis of the MPZ and PMP22 Genes in Croatian Patients
  5. Dynamic Equilibrium between Protein S and C4b Binding Protein Is Important for Accurate Determination of Free Protein S Antigen
  6. Immunoassay of Anti-Thyroid Autoantibodies: High Analytical Variability in Second Generation Methods
  7. The Measurement of Insulin-like Growth Factor-I (IGF-1) Concentration in Random Urine Samples
  8. Urinary Bikunin Determination Provides Insight into Proteinase/Proteinase Inhibitor Imbalance in Patients with Inflammatory Diseases
  9. Breath Markers and Soluble Lipid Peroxidation Markers in Critically Ill Patients
  10. Comparison of Laser-Probe and Photometric Determination of the Urinary Crystallization Risk of Calcium Oxalate
  11. Comparison of First Trimester, Second Trimester and Integrated Downs Syndrome Screening Results in Unaffected Pregnancies
  12. Anti-Phospholipid Antibodies in Diabetes Mellitus
  13. Alteration of Serum Enzymes in Primary Hypothyroidism
  14. The Changes of Superoxide Dismutase, Catalase and Glutathione Peroxidase Activities in Erythrocytes of Active and Passive Smokers
  15. Internal Quality Control System for Non-Stationary, Non-Ergodic Analytical Processes Based upon Exponentially Weighted Estimation of Process Means and Process Standard Deviation
  16. Evaluation of Commutability of Control Materials
  17. IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes
  18. IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase
  19. IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase
  20. Meetings and Awards
Downloaded on 15.10.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2002.108/html