Home IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes
Article
Licensed
Unlicensed Requires Authentication

IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes

  • L. Siekmann , R. Bonora , C. A. Burtis , F. Ceriotti , P. Clerc-Renaud , G. Férard , C. A. Ferrero , J.-C. Forest , P. F.H. Franck , F.-J. Gella , W. Hoelzel , P. J. Jørgensen , T. Kanno , A. Kessner , R. Klauke , N. Kristiansen , J.-M. Lessinger and T. P. J. Linsinger
Published/Copyright: June 1, 2005
Become an author with De Gruyter Brill
Clinical Chemistry and Laboratory Medicine (CCLM)
From the journal Volume 40 Issue 6

Abstract

This paper is the first in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C and with the certification of reference preparations. Other parts deal with:

Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of γ-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of γ-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37°C.

A document describing the determination of preliminary reference values is also in preparation.

:
Published Online: 2005-06-01
Published in Print: 2002-06-21

Copyright © 2002 by Walter de Gruyter GmbH & Co. KG

Articles in the same Issue

  1. IFCC Primary Reference Procedures for the Measurement of Catalytic Concentrations of Enzymes – the New Concept
  2. Allele Frequency of the G→T Mutation of the Col1A1 Gene Analyzed by an ARMS-PCR in Osteoporotic Subjects with Femoral Neck Fractures
  3. Vitamin Supplementation Normalizes Total Plasma Homocysteine Concentration but Not Plasma Homocysteine Redox Status in Patients with Acute Coronary Syndromes and Hyperhomocysteinemia
  4. Mutation Analysis of the MPZ and PMP22 Genes in Croatian Patients
  5. Dynamic Equilibrium between Protein S and C4b Binding Protein Is Important for Accurate Determination of Free Protein S Antigen
  6. Immunoassay of Anti-Thyroid Autoantibodies: High Analytical Variability in Second Generation Methods
  7. The Measurement of Insulin-like Growth Factor-I (IGF-1) Concentration in Random Urine Samples
  8. Urinary Bikunin Determination Provides Insight into Proteinase/Proteinase Inhibitor Imbalance in Patients with Inflammatory Diseases
  9. Breath Markers and Soluble Lipid Peroxidation Markers in Critically Ill Patients
  10. Comparison of Laser-Probe and Photometric Determination of the Urinary Crystallization Risk of Calcium Oxalate
  11. Comparison of First Trimester, Second Trimester and Integrated Downs Syndrome Screening Results in Unaffected Pregnancies
  12. Anti-Phospholipid Antibodies in Diabetes Mellitus
  13. Alteration of Serum Enzymes in Primary Hypothyroidism
  14. The Changes of Superoxide Dismutase, Catalase and Glutathione Peroxidase Activities in Erythrocytes of Active and Passive Smokers
  15. Internal Quality Control System for Non-Stationary, Non-Ergodic Analytical Processes Based upon Exponentially Weighted Estimation of Process Means and Process Standard Deviation
  16. Evaluation of Commutability of Control Materials
  17. IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes
  18. IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase
  19. IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase
  20. Meetings and Awards
Downloaded on 3.10.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2002.109/html
Scroll to top button