Comparison of Different Immunoassays for CA 19-9
-
Petr Stern
Abstract
We compared six routinely employed immunoassay kits: Architect i2000 and AxSYM, Abbott Laboratories; Elecsys 2010, Roche Diagnostics; ELSA, CIS-BioInternational; Immulite 1, Diagnostic Products Corporation; and IRMA-mat, Byk-Sangtec Diagnostica. Using all analytical systems, we measured identical groups of clinical samples completed with selected control samples. The repeatability of measurements (coefficient of variation) ranged from 2.1% (Elecsys 2010) to 6.7% (ELSA). The parameters of Passing-Bablok regression show significant systematic differences among analytical systems. Data from a Bland-Altman diagram suggest that these differences project onto other, still more significant individual differences among individual samples. Though the cut-off values differ between various systems, no similar clinical efficacy appears to be attained. The behavior of individual systems is quite different for identical control materials and does not necessarily duplicate the calibration for biological samples. The results of determining CA 19–9 cannot be extrapolated from one analytical technique to another, even in cases where the same monoclonal antibody is used. Standardization of CA 19–9 measurement systems is necessary to allow use of the results for the purposes of evidence-based medicine.
Copyright (c) 2001 by Walter de Gruyter GmbH & Co. KG
Articles in the same Issue
- Contents
- Subject Index
- Author Index
- Summary of the 2nd Sino-European Congress of Laboratory Medicine
- Laboratory Diagnosis of Viral Hepatitis in China: The Present and the Future
- Molecular Diagnostics in China
- Detection of Usual and Atypical Aldehyde Dehydrogenase Alleles by Mismatch Amplification Mutation Assay
- Expression of Prostaglandin D Synthase in Ovarian Cancer
- Carrier Detection and Prenatal Diagnosis of Hemophilia A
- Detection of Oligoclonal Immunoglobulins in the Cerebrospinal Fluid by Immunofixation Electrophoresis
- 2nd Sino-European Congress of Laboratory Medicine – Strategies for Laboratory Diagnostics in Medicine
- The Problems and Strategy relevant to the Quality Management of Clinical Laboratories
- Computer Application to the Laboratory Management in Hospital
- The Basis of the Synovial Fluid Analysis
- Determination of Tumor Markers in Serum. Pitfalls and Good Practice
- Gas Chromatography-Mass Spectrometry Measurement of 6β-OH-Cortisol/Cortisol Ratio in Human Urine: A Specific Marker of Enzymatic Induction
- No Variation in Hsp70 mRNA Level during Cardiac Surgery in Pediatric Patients Evaluated by Semiquantitative RT-PCR
- Rapid Detection of Macroprolactin in tHe Form of Prolactin-Immunoglobulin G Complexes by Immunoprecipitation with Anti-human IgG-Agarose
- Molecular Characterization of Chromosome 22 Deletions by Short Tandem Repeat Polymorphism (STRP) in Patients with Conotruncal Heart Defects
- A Simple and Rapid Analysis of Triplet Repeat Diseases by Expand Long PCR
- The Effects of Peroxynitrite on Erythrocytes
- The Use of Hirudin as Universal Anticoagulant in Haematology, Clinical Chemistry and Blood Grouping
- Comparison of Different Immunoassays for CA 19-9
- The Evaluation of Analytical Performance of the Precision G Point-of-Care Glucometer
- On Painting and Philosophy: Sir Henry Raeburn
- Acknowledgement
- Meetings and Awards
Articles in the same Issue
- Contents
- Subject Index
- Author Index
- Summary of the 2nd Sino-European Congress of Laboratory Medicine
- Laboratory Diagnosis of Viral Hepatitis in China: The Present and the Future
- Molecular Diagnostics in China
- Detection of Usual and Atypical Aldehyde Dehydrogenase Alleles by Mismatch Amplification Mutation Assay
- Expression of Prostaglandin D Synthase in Ovarian Cancer
- Carrier Detection and Prenatal Diagnosis of Hemophilia A
- Detection of Oligoclonal Immunoglobulins in the Cerebrospinal Fluid by Immunofixation Electrophoresis
- 2nd Sino-European Congress of Laboratory Medicine – Strategies for Laboratory Diagnostics in Medicine
- The Problems and Strategy relevant to the Quality Management of Clinical Laboratories
- Computer Application to the Laboratory Management in Hospital
- The Basis of the Synovial Fluid Analysis
- Determination of Tumor Markers in Serum. Pitfalls and Good Practice
- Gas Chromatography-Mass Spectrometry Measurement of 6β-OH-Cortisol/Cortisol Ratio in Human Urine: A Specific Marker of Enzymatic Induction
- No Variation in Hsp70 mRNA Level during Cardiac Surgery in Pediatric Patients Evaluated by Semiquantitative RT-PCR
- Rapid Detection of Macroprolactin in tHe Form of Prolactin-Immunoglobulin G Complexes by Immunoprecipitation with Anti-human IgG-Agarose
- Molecular Characterization of Chromosome 22 Deletions by Short Tandem Repeat Polymorphism (STRP) in Patients with Conotruncal Heart Defects
- A Simple and Rapid Analysis of Triplet Repeat Diseases by Expand Long PCR
- The Effects of Peroxynitrite on Erythrocytes
- The Use of Hirudin as Universal Anticoagulant in Haematology, Clinical Chemistry and Blood Grouping
- Comparison of Different Immunoassays for CA 19-9
- The Evaluation of Analytical Performance of the Precision G Point-of-Care Glucometer
- On Painting and Philosophy: Sir Henry Raeburn
- Acknowledgement
- Meetings and Awards