Comparison of Different Immunoassays for CA 19-9

  • Petr Stern , Bedrich Friedecky , Vladimir Bartos , Drahomira Bezdickova , Jaroslava Vavrova , Jana Uhrova , Ladislava Rozprimova , Tomas Zima and Vladimir Palicka
Published/Copyright: June 1, 2005
Become an author with De Gruyter Brill
Clinical Chemistry and Laboratory Medicine (CCLM)
From the journal Volume 39 Issue 12

Abstract

We compared six routinely employed immunoassay kits: Architect i2000 and AxSYM, Abbott Laboratories; Elecsys 2010, Roche Diagnostics; ELSA, CIS-BioInternational; Immulite 1, Diagnostic Products Corporation; and IRMA-mat, Byk-Sangtec Diagnostica. Using all analytical systems, we measured identical groups of clinical samples completed with selected control samples. The repeatability of measurements (coefficient of variation) ranged from 2.1% (Elecsys 2010) to 6.7% (ELSA). The parameters of Passing-Bablok regression show significant systematic differences among analytical systems. Data from a Bland-Altman diagram suggest that these differences project onto other, still more significant individual differences among individual samples. Though the cut-off values differ between various systems, no similar clinical efficacy appears to be attained. The behavior of individual systems is quite different for identical control materials and does not necessarily duplicate the calibration for biological samples. The results of determining CA 19–9 cannot be extrapolated from one analytical technique to another, even in cases where the same monoclonal antibody is used. Standardization of CA 19–9 measurement systems is necessary to allow use of the results for the purposes of evidence-based medicine.

:
Published Online: 2005-06-01
Published in Print: 2001-12-07

Copyright (c) 2001 by Walter de Gruyter GmbH & Co. KG

Articles in the same Issue

  1. Contents
  2. Subject Index
  3. Author Index
  4. Summary of the 2nd Sino-European Congress of Laboratory Medicine
  5. Laboratory Diagnosis of Viral Hepatitis in China: The Present and the Future
  6. Molecular Diagnostics in China
  7. Detection of Usual and Atypical Aldehyde Dehydrogenase Alleles by Mismatch Amplification Mutation Assay
  8. Expression of Prostaglandin D Synthase in Ovarian Cancer
  9. Carrier Detection and Prenatal Diagnosis of Hemophilia A
  10. Detection of Oligoclonal Immunoglobulins in the Cerebrospinal Fluid by Immunofixation Electrophoresis
  11. 2nd Sino-European Congress of Laboratory Medicine – Strategies for Laboratory Diagnostics in Medicine
  12. The Problems and Strategy relevant to the Quality Management of Clinical Laboratories
  13. Computer Application to the Laboratory Management in Hospital
  14. The Basis of the Synovial Fluid Analysis
  15. Determination of Tumor Markers in Serum. Pitfalls and Good Practice
  16. Gas Chromatography-Mass Spectrometry Measurement of 6β-OH-Cortisol/Cortisol Ratio in Human Urine: A Specific Marker of Enzymatic Induction
  17. No Variation in Hsp70 mRNA Level during Cardiac Surgery in Pediatric Patients Evaluated by Semiquantitative RT-PCR
  18. Rapid Detection of Macroprolactin in tHe Form of Prolactin-Immunoglobulin G Complexes by Immunoprecipitation with Anti-human IgG-Agarose
  19. Molecular Characterization of Chromosome 22 Deletions by Short Tandem Repeat Polymorphism (STRP) in Patients with Conotruncal Heart Defects
  20. A Simple and Rapid Analysis of Triplet Repeat Diseases by Expand Long PCR
  21. The Effects of Peroxynitrite on Erythrocytes
  22. The Use of Hirudin as Universal Anticoagulant in Haematology, Clinical Chemistry and Blood Grouping
  23. Comparison of Different Immunoassays for CA 19-9
  24. The Evaluation of Analytical Performance of the Precision G Point-of-Care Glucometer
  25. On Painting and Philosophy: Sir Henry Raeburn
  26. Acknowledgement
  27. Meetings and Awards
Downloaded on 20.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2001.205/html
Scroll to top button