Detection and Quantification of Small Numbers of Circulating Tumour Cells in Peripheral Blood Using Laser Scanning Cytometer (LSC®)
-
Katharina Pachmann
Abstract
The detection of circulating tumour cells disseminated from solid tumours requires extremely sensitive methods. Molecular genetic methods, which are most sensitive, are not applicable to solid tumours because no tumour-specific genetic markers are available. Detection of disseminated tumour cells by immunocytochemistry is time-consuming, whereas fluorimetry is fast and quantitative. The laser scanning cytometer (LSC®) provides an automated microscopic procedure for screening up to 5×104 cells in suitable time. Using this system together with an enrichment procedure which allows up to ten thousand-fold enrichment, we have quantified minimal numbers of tumour cells. In a model system, breast cancer cell line cells diluted into peripheral blood mimicked seeding of tumour cells into the periphery. After staining with fluorochrome-conjugated anti-epithelial antibody, slides were screened for positive events directly or after enrichment with antibody-coated magnetic beads. One positive cell was unequivocally detectable in 104 cells and 50 out of 60 tumour cells were reliably recovered from a 20 ml blood volume, equal to 1–2 cells per 107, after magnetic bead enrichment.
This method allows quantitation of tumour cells in peripheral blood and bone marrow in reasonable time and will, for the first time, enable extensive investigation of the seeding behaviour of tumours.
Copyright © 2001 by Walter de Gruyter GmbH & Co. KG
Articles in the same Issue
- Joint Meeting of the German Society of Clinical Chemistry and of the German Society of Laboratory Medicine, Rostock, 1619 September 2001
- Herbert Keller January 16, 1925 June 25, 2001
- Routine Differential Diagnosis of Proteinurias by Capillary Electrophoresis
- Diagnostic Testing in Epstein-Barr Virus Infection
- Establishing a Reference System in Clinical Enzymology
- Prediction of the Development of Pregnancy-Induced Hypertensive Disorders in High-Risk Pregnant Women by Artificial Neural Networks
- Fast Homogeneous Assay for Plasma Procarboxypeptidase U
- Detection and Quantification of Small Numbers of Circulating Tumour Cells in Peripheral Blood Using Laser Scanning Cytometer (LSC®)
- Monotherapy with Metformin: Does It Improve Hypoxia in Type 2 Diabetic Patients?
- Cigarette Smoking and Hypertension Influence Nitric Oxide Release and Plasma Levels of Adhesion Molecules
- The Effect of Corticosteroids on Serum and Cerebrospinal Fluid Nitric Oxide Levels in Multiple Sclerosis
- Glutathione Transferase P1 Polymorphism in Neuroblastoma Studied by Endonuclease Restriction Mapping
- Biological Variation of Interleukin-1β, Interleukin-8 and Tumor Necrosis Factor-α in Serum of Healthy Individuals
- Reference Intervals and Variation for Urinary Epinephrine, Norepinephrine and Cortisol in Healthy Men and Women in Denmark
- Determination of Serum Cystatin C: Biological Variation and Reference Values
- Certification of the Mass Concentration of Creatine Kinase Isoenzyme 2 (CK-MB) in the Reference Material BCR 608
- Carbohydrate-Deficient Transferrin (CDT) Determination by Nephelometry Using a Commercial Kit. Analytical and Diagnostic Aspects
- Higher CK-MB Mass Values in Heparin Plasma than in Serum Measured with the Abbott AxSYM™ System
- Clinical Case Material for Teaching Clinical Chemistry and Laboratory Medicine
- IFCC News
- Meetings
Articles in the same Issue
- Joint Meeting of the German Society of Clinical Chemistry and of the German Society of Laboratory Medicine, Rostock, 1619 September 2001
- Herbert Keller January 16, 1925 June 25, 2001
- Routine Differential Diagnosis of Proteinurias by Capillary Electrophoresis
- Diagnostic Testing in Epstein-Barr Virus Infection
- Establishing a Reference System in Clinical Enzymology
- Prediction of the Development of Pregnancy-Induced Hypertensive Disorders in High-Risk Pregnant Women by Artificial Neural Networks
- Fast Homogeneous Assay for Plasma Procarboxypeptidase U
- Detection and Quantification of Small Numbers of Circulating Tumour Cells in Peripheral Blood Using Laser Scanning Cytometer (LSC®)
- Monotherapy with Metformin: Does It Improve Hypoxia in Type 2 Diabetic Patients?
- Cigarette Smoking and Hypertension Influence Nitric Oxide Release and Plasma Levels of Adhesion Molecules
- The Effect of Corticosteroids on Serum and Cerebrospinal Fluid Nitric Oxide Levels in Multiple Sclerosis
- Glutathione Transferase P1 Polymorphism in Neuroblastoma Studied by Endonuclease Restriction Mapping
- Biological Variation of Interleukin-1β, Interleukin-8 and Tumor Necrosis Factor-α in Serum of Healthy Individuals
- Reference Intervals and Variation for Urinary Epinephrine, Norepinephrine and Cortisol in Healthy Men and Women in Denmark
- Determination of Serum Cystatin C: Biological Variation and Reference Values
- Certification of the Mass Concentration of Creatine Kinase Isoenzyme 2 (CK-MB) in the Reference Material BCR 608
- Carbohydrate-Deficient Transferrin (CDT) Determination by Nephelometry Using a Commercial Kit. Analytical and Diagnostic Aspects
- Higher CK-MB Mass Values in Heparin Plasma than in Serum Measured with the Abbott AxSYM™ System
- Clinical Case Material for Teaching Clinical Chemistry and Laboratory Medicine
- IFCC News
- Meetings