Abstract

Background: The 24-h urine sample is considered as the most reliable material for testing many but not necessarily all constituents in urine. However, its collection is tedious for both patients and research participants. The aim of this study was to compare concentrations of essential elements calcium (Ca), magnesium (Mg), sodium (Na), potassium (K), and zinc (Zn) in 24-h and spot urine samples.

Methods: Urine samples were collected from 143 generally healthy women, aged 30–79 years. Fasting spot urine was collected immediately after the end of the 24-h collection, therefore being of the same content as the first morning urine which ended the 24-h collection. Elements were analyzed by flame atomic absorption/emission spectrometry and expressed as mg/g and/or mmol/mol of creatinine (Cr). Spearman rank order correlations between 24-h and spot urine were carried out for each element. Ratios of elements in 24-h to spot urine samples were calculated to estimate the element-proportion of spot in the 24-h sample.

Results: All coefficients of correlation between 24-h and spot urine of measured elements and Cr were significant (p<0.05): Zn (0.637), Mg (0.623), Ca (0.603), Na (0.452), K (0.396), and Cr (0.217). Ratios of 24-h to spot urine samples for each element (except K) were similar and close to 2, indicating uniform proportion of elements from spot urine sample in the 24-h sample. In addition, a high correlation between various pairs of elements was obtained in both 24-h and spot urine; the highest being between Na/Ca (0.435) and (0.578), respectively. This is in accordance with theoretical presumptions and previous findings regarding those relationships.

Conclusions: Although replacing burdensome 24-h urine collection with spot urine sampling might not provide the solution in all cases, our results show that for the elements analyzed, spot urine could be a reliable alternative.

Clin Chem Lab Med 2009;47:216–21.


Corresponding author: Jasminka Ilich, PhD, RD, Professor, Nutrition, Food and Exercise Sciences, Florida State University, 120 Convocation Way, 418 Sandels Bldg, Tallahassee, FL 32306-1493, USA Phone: +1-850-645-7177, Fax: +1-850-645-5000,

Received: 2008-9-6
Accepted: 2008-11-3
Published Online: 2009-02-01
Published in Print: 2009-02-01

©2009 by Walter de Gruyter Berlin New York

Articles in the same Issue

  1. Editorial
  2. 50th Anniversary of SBCC/BVKC: “International Symposium Brussels 2008: New Trends in Clinical Biology. Emerging Technologies and their Impact on Laboratory Medicine and Management”
  3. Reviews
  4. Vitamin D: current status and perspectives
  5. Circulating oxidized low-density lipoprotein: a biomarker of atherosclerosis and cardiovascular risk?
  6. New European guidelines for cardiovascular disease prevention in clinical practice
  7. Review
  8. Causes, consequences, detection, and prevention of identification errors in laboratory diagnostics
  9. Genetics and Molecular Diagnostics
  10. The PCSK9 gene E670G polymorphism affects low-density lipoprotein cholesterol levels but is not a risk factor for coronary artery disease in ethnic Chinese in Taiwan
  11. Polymorphisms and plasma soluble levels of E-selectin in patients with chronic hepatitis B virus infection
  12. General Clinical Chemistry and Laboratory Medicine
  13. Effect of high levels of human chorionic gonadotropin and estradiol on the severity of hyperemesis gravidarum
  14. Freeze-thaw and matrix effects in direct high-density lipoprotein cholesterol methods
  15. Methodology for monitoring cytomegalovirus infection after renal transplantation
  16. High concentrations of haptocorrin interfere with routine measurement of cobalamins in human serum and milk. A problem and its solution
  17. Reference Values and Biological Variations
  18. Inter- and intra-individual variations of urinary endogenous metabolites in healthy male college students using 1H NMR spectroscopy
  19. Preanalytical errors in primary healthcare: a questionnaire study of information search procedures, test request management and test tube labelling
  20. Age and hormone replacement therapy as factors influencing androgen levels in the postmenopausal female
  21. Preheparin serum lipoprotein lipase mass interacts with gender, gene polymorphism and, positively, with smoking
  22. Validation and Outcome Studies
  23. Comparison of calcium, magnesium, sodium, potassium, zinc, and creatinine concentration in 24-h and spot urine samples in women
  24. Performance of free β-human chorionic gonadotrophin (free β-hCG) and pregnancy associated plasma protein-A (PAPP-A) analysis between Delfia Xpress and AutoDelfia systems in The Netherlands
  25. A pilot survey of the use and implementation of cardiac markers in acute coronary syndrome and heart failure across Europe The CARdiac MArker Guideline Uptake in Europe (CARMAGUE) study
  26. Letters to the Editor
  27. Interference of IgM-λ paraprotein with biuret-type assay for total serum protein quantification
  28. Evaluation of BD Vacutainer® PST™II tubes for a wide range of immunoassays
  29. Native prothrombin as an alternative to prothrombin time determination for monitoring oral anticoagulant therapy
Downloaded on 28.10.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2009.039/html
Scroll to top button