Abstract

Aim: To evaluate the use of three-dimensional ultrasonography (3D) as an alternative for examining fetal anatomy and nuchal translucency (NT) in the 1st trimester of pregnancy.

Method: Prospective study of 199 low risk pregnant women undergoing 1st trimester ultrasound scan for fetal anomalies. The NT and fetal anatomy were evaluated by three-dimensional (3D) ultrasonography after the standard two-dimensional (2D) examination. The gold standard in this study was the 2D ultrasonography.

Results: In some of the evaluated parameters the 3D method approaches the conventional 2D results. These parameters are the crown-rump length (CRL), the skull – brain anatomy (93.5%), the spine (85.4%), the upper (88.4%) and lower limbs (87.9%) and the examination of the fetal abdomen (98.5%). Some of the anatomic parameters under evaluation revealed a statistically significant difference in favor of the 2D examination. During the 3D examination the nasal bone was identified in 62.1% of the cases, the stomach in 85.9%, and the urinary bladder in 57.3% of the cases. The NT was assessed accurately in half of the cases compared to 2D examination.

Conclusion: The 3D ultrasound is insufficient for the detailed fetal anatomy examination during the 1st trimester of pregnancy. Nevertheless, the method might be improved in order to be considered as a screening method.


Corresponding author: Dr. Eleftherios Anastasakis 14, Kountouriotou Street Ano Vrilissia 152 35 Athens Greece Tel.: +30 6944697762 Fax: +30 210 8054928

Received: 2010-5-23
Accepted: 2010-12-7
Published Online: 2011-02-10
Published Online: 2011-02-10
Published in Print: 2011-03-01

©2011 by Walter de Gruyter Berlin New York

Articles in the same Issue

  1. Recommendations and guidelines for perinatal practice
  2. Twin-to-twin transfusion syndrome (TTTS)*
  3. Expert panel recommendation
  4. Expert recommendations for the diagnosis and treatment of iron-deficiency anemia during pregnancy and the postpartum period in the Asia-Pacific region
  5. Review article
  6. Weight gain and dietary intake during pregnancy in industrialized countries – a systematic review of observational studies
  7. Original articles – Obstetrics
  8. Clinical significance of oligohydramnios in patients with preterm labor and intact membranes*,**
  9. Placental volume and vascularization flow indices by 3D power Doppler US using VOCAL technique and correlation with IGF-1, free beta-hCG, PAPP-A, and uterine artery Doppler at 11–14 weeks of pregnancy
  10. The impact of umbilical and uterine artery Doppler indices on antenatal course, labor and delivery in a low-risk primigravid population
  11. C-reactive protein levels at pre-/post-indicated cervical cerclage predict very preterm birth
  12. Role of the vascular endothelial growth factor in the inverse relationship between increased nuchal translucency thickness and fetomaternal transfusion
  13. Birth defects among a cohort of infants born to HIV-infected women on antiretroviral medication
  14. Original articles – Fetus
  15. Neurobehavioral continuity from fetus to neonate
  16. Obstetrical risk factors for focal intestinal perforation in very low birth weight infants
  17. Assessment of nuchal translucency thickness and the fetal anatomy in the first trimester of pregnancy by two- and three-dimensional ultrasonography: a pilot study
  18. Why are monozygotic twins different?
  19. Original article – Newborn
  20. The impact of clinical maternal chorioamnionitis on neurological and psychological sequelae in very-low-birth weight infants: a case-control study
  21. Short communication
  22. Normal fasting plasma glucose levels during pregnancy: a hospital-based study
  23. Letters to the Editor
  24. Syndrome of inappropriate antidiuretic hormone secretion after cesarean section complicated with hemorrhage
  25. Acceptability of the fetal electrocardiographic (STAN®) monitoring system by staff at a high-risk maternity unit
  26. Reply: A great lack of knowledge regarding umbilical cord blood banking among pregnant women in Berlin, Germany
  27. Congress calendar
  28. Congress Calendar
Downloaded on 16.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/jpm.2010.156/html
Scroll to top button