Abstract
The need to capture the maximum amount of solar energy and to optimize the panels’ collecting surfaces are among the primary objectives of research in solar engineering. The simplest way to accomplish this is to perform a monthly accurate determination of the solar collector’s proper slope and azimuth angles. Indeed, this is the aim of this article, which consists of a graphical optimization based on the Gueymard’s daily integration model. A Matlab program was developed to predict the hourly solar radiation on a solar receiver using the Gueymard model in conjunction with the Liu and Jordan isotropic, Perez, and HDKR anisotropic models. A comprehensive simulation of the monthly solar irradiation throughout 2018 was executed for the city of Annaba, in north–eastern Algeria. The results indicate that the south-facing surface azimuth angle is the most appropriate. In fact, for maximum sunlight capture, the solar collector inclination must be adjusted each month in the range of [10–40°]. Furthermore, the results show that the gains in the amount of solar radiation received throughout the year by the thermal panel mounted at monthly optimum tilt angles are 15.63% in January and 7.37% in July.
Introduction
The fact that a large volume of meteorological radiation and temperature data must be analyzed has made the prediction of collector performance an extremely tedious task. It is, therefore, desirable to study the available radiation and temperature data and to correlate and present them in such a form that further detailed analysis of these data becomes unnecessary in the prediction of collector performance.
Methods for predicting the long-term average insolation available to solar correctors, both fixed and tracking, and of arbitrary orientation, have been described by Liu and Jordan (1963), Collares-Pereira and Rabl (1979), and Erbs, Klein, and Duffie (1982), recognized as the prediction models for collector performance. To apply these methods, a large volume of meteorological radiation and temperature data for the locality of the collector must be analyzed.
It is well known that the time when we can capture the maximum of solar radiation is between noon and 1 pm. The fact remains that it is more interesting to study the evolution of the sunshine intensity from sunrise to sunset, considering different estimations of inclination and azimuth angles for a tilted surface. Eminent researchers and authors have studied the inclination effects of the sensor’s receiving surface on the global daily radiation collected and its relationship with the local latitude L (Duffie and Beckman 2013; Goswami 2015). They have explained how to get the optimum tilt angle that captures the maximum energy and recommend the following optimal slope angles: βopt = L + 15° for winter periods, βopt = L − 15° for summers, and a fixed value of βopt = L for yearly use. However, it was found that a deviation of 15° from the optimum produced a decrease in the captured solar energy of about 5%.
Researchers are working to improve the performance of the thermal efficiency and outlet temperature of the solar thermal processes. Mzad et al. have scrutinized, experimentally and numerically, double-glazed solar collectors tested in different locations in Algeria using the Collares-Pereira and Erbs models. The thermal parameters of the studied sensor in the north–western country, such as the variation of fluid temperature and the panel efficiency, were calculated using only the measured global-horizontal radiation (Mzad 2008). The solar air collector investigated in the north–east part of the country allowed the determination of the useful energy and the efficiency using a tilt and orientation optimization (Mzad et al. 2018). A trial solar air heater (SAH) was constructed and subjected to performance testing (Mzad, Bey, and Khelif 2019). The designed panel was able to procure an efficiency of 50% almost all year for an air flow rate of 52 m3/h/m2, and a useful energy of around 4500 W. The thermal performance simulation achieved allowed the estimation of daily solar radiation, useful power, and collector efficiency.
A novel SAH design with long-term heating, especially during off-sunny hours, was found to deliver high thermal efficiencies of up to 80% with forced convection (Saxena, Srivastava, and Tirth 2015). A mixture of desert and granular carbon has been used as thermal heat storage inside the SAH, and two halogen lights were placed in the inlet and outlet ducts.
Experimental and numerical investigations into the effect of porous metal foam on the performance of a flat-plate solar collector have been carried out (Saedodin et al. 2017). The numerical results show that the maximum thermal performance is obtained in a porous layer with a dimensionless thickness greater than 0.8. In the experimental section, the effects of metal foam on the solar collector performance at different flow rates were examined. Numerical and experimental results have shown that using the porous medium enhances the maximum thermal efficiency and Nusselt number.
Mahmood (2020) invented a new SAH design using a double-pass unglazed transpired collector. The absorbing area was increased by using wire mesh layers, and the thermal performance was enhanced by using a perforated absorber plate and a double-pass counter-flow collector in the duct.
A mathematical model was used to estimate the total solar radiation on the tilted PV surface and to determine the optimum tilt angles for a PV panel installed in Sanliurfa, Turkey (Kacira et al. 2004). The optimum tilt angles were determined using fixed and solar tracking panels. This study concluded that the monthly optimum tilt angle changes throughout the year, with a minimum value of 13° in June and a maximum value of 61° in December.
Based on an isotropic radiation model of the sky, the numerical approach proposed by Li and Lam (2007) allows predicting the solar radiation on inclined surfaces of different orientations using the measured sky radiances in the city of Hong Kong. They found that the maximum value of the tilt angle was 30° when the azimuth angle of the surface was 210°.
Jamil Ahmad and Tiwari (2009) have optimized the tilting of solar flat-plate collectors facing toward the equator using New Delhi as a reference. The calculations were based upon the measured values of the monthly mean of global and diffuse solar radiation on a horizontal surface. The annual optimum tilt angle was found to be approximately equal to the latitude of the location, and the loss in the amount of collected energy was only around 1% if the angle of tilt is adjusted seasonally.
The possibility of reducing the number of solar cooling panels based on evacuated tubes producing hot water at a low temperature (90 °C) and a water-ammonia absorption chiller was demonstrated by Corrada et al. (2014) in the South–East Queensland region. Calculations using the Liu and Jordan model suggest that the flat panel configuration is the best solution for a solar cooling and heating system, considering the cost involved in the installation and maintenance of a variable angle system.
Elminir et al. (2006) have investigated the optimum tilt and orientation angles for solar flat-plate collectors used in Helwan, Egypt. They have performed a statistical comparison of three specific anisotropic models (Tamps-Coulson, Perez, and Bugler) to use the one that provides the most accurate estimation of the total solar radiation. The study revealed that the Perez model shows the best overall calculated performance.
A simple mathematical procedure for the estimation of the optimal tilt angle of a collector was presented based on the monthly horizontal radiation (Tang and Wu 2004). The optimal tilt angle of the south-facing collectors was outlined based on the monthly horizontal radiation of 152 places around China, except for places with a considerably lower clearness index. The optimal tilt angle of other 30 cities was determined based on the actual monthly diffuse radiation.
Handoyo, Ichsani, and Prabowo (2013) have obtained an equation delivering the optimal angle of a solar collector installed in Surabaya, Indonesia. The result was compared to the work of Tang et al. and Duffie and Beckman’s equations, and confirmed the validity of the equation to obtain the optimal tilt angle. They have also proposed a two-collector configuration, one facing east to be used in the morning and one facing west in the afternoon. The optimal tilt angle for these orientations was located between 36° and 39.4°.
An optimization study of the positioning of a solar energy receiver to improve the energetic gain with the Liu-Jordan isothropic mathematical model has been carried out (Frydrychowicz-Jastrzębska 2011). The influence of the reflectivity coefficient of the ground and the transparency coefficient of the atmosphere on the investigated angle has been taken into account. The simulation revealed that 32° was the optimum angle, independently of the season, for the city of Warsaw.
Kambezidis and Psiloglou (2021) have demonstrated a new way of defining the optimal tilt angle of a solar collector in Greece that faces south. This methodology has also been implemented for finding the optimum tilt angle of flat-plate solar panels in Saudi Arabia for fixed-tilt to the south, fixed-tilt tracking the Sun, and variable-tilt tracking the Sun configurations (Farahat et al. 2021a, 2021b, 2022; Kambezidis et al. 2021). In both countries, certain constant tilt angles were determined all over the year for the first and second configuration modes.
A solar collector’s efficiency will increase when it is always facing the sun, which means a tracking system is required. A tracking system is too expensive for people who live in the hills of the city of Annaba, our case study. In this paper, the estimation of optimal angles (surface tilt and azimuth) is obtained by solving the daily integration model of Gueymard (2000) and three interlinked optimization models. Fundamental solar radiation equations were programmed, using a Matlab code, to determine optimum angles via maximizing the angle of incidence of beam radiation on the collector. Obtained graphs, generating average monthly radiation, are analyzed to investigate solar radiation at some tilt angles. The results are then compared to two experimental studies in order to determine suitable periodic optimum tilt angles for solar collectors at the current latitude. The performed simulation allows a limited number of intervals per year for panel setting. The user does not need to change the collector position every month.
Site information and solar radiation modeling
Site’s data
Based on the meteorological data available for the site of Annaba city in 2018, we apply the Gueymard model in order to graphically estimate the appropriate angles of solar panels. The city of Annaba is located in the northeast of Algeria in the Mediterranean Sea, 600 km from the capital, Algiers, and close to the Tunisian border. The place’s geographical coordinates are:
L = 36°54′47″ North and llocal = 07°43′54″ East.
Klein (1977) proposed the mean day of the month, which is a date where the declination is closest to the mean declination of that month (Table 1). Using the mean day of each month can lead to small errors in the monthly extraterrestrial radiation mean value
Daily-average global radiation on a horizontal surface, 2018 (PVGIS database website 2018).
| Month | Jan. | Feb. | Mar. | Apr. | May | Jun. | Jul. | Aug. | Sep. | Oct. | Nov. | Dec. |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mean day | 17 | 16 | 16 | 15 | 15 | 11 | 17 | 16 | 15 | 15 | 14 | 10 |
| Day of the year | 17 | 47 | 75 | 105 | 135 | 162 | 198 | 228 | 258 | 288 | 318 | 344 |
| H h , [kW/m2] | 1.841 | 3.121 | 4.570 | 6.991 | 7.909 | 7.002 | 8.113 | 6.671 | 4.638 | 4.484 | 2.822 | 2.798 |
Solar radiation on a horizontal plane
The declination is the angle between the Earth–Sun line and the equatorial plane, which is a function of the time of the year and, therefore, it varies from +23.5° on June 21 to −23.5° on December 21. This angle can be calculated with an accuracy of ±0.035° using the equation (Duffie and Beckman 2013):
With,
The sunset/sunrise angle depends on the declination angle and is defined as:
And the day length is calculated as:
The sun’s position is marked by two important angles, the zenith and the azimuth. According to Duffie and Beckman (2013), the zenithal angle of the sun is calculated by the equation:
where the hourly angle of the sun can be written as:
The solar time equation is:
where the equation of time is given by:
The solar azimuth angle is the angle formed by the sun’s rays in the horizontal plane with respect to the south:
Extraterrestrial solar radiation is the power of the sun to a horizontal surface at the top of the Earth’s atmosphere, expressed as follows (Kalogirou 2014):
Where k = 24/π and GSC = 1.3661 kW/m2, the new measured solar constant value (Goswami 2015).
R is the correction factor of the sun–earth distance. According to Goswami (2015), the expression of R is:
The clearness index, for the month “m”, represents the ratio of solar radiation that penetrates the atmosphere to extraterrestrial irradiation:
Where Hh(m) is the daily total solar radiation on a horizontal surface, which values are mentioned in Table 1.
The average daily diffuse radiation on a horizontal surface is given by the following De Miguel et al. (2001) correlation, well suited to the region enclosing the Mediterranean Sea:
The daily direct radiation on the horizontal plane is merely deduced by:
The Gueymard DI model
The approach consists of superimposing graph curves of solar radiation falling on the panel surface at a fixed orientation with those at different tilts. So, this procedure is repeated each time the orientation of the sensor changes to obtain a group of four figures every single month. This graphical optimization method is based on a number of parameters like the average daily radiation value of the studied location, which includes the typical day and the appropriate diffuse radiation model for the situation.
The Gueymard coefficients are described as follows:
And the relationship of hourly and daily diffuse radiations on a horizontal surface, given by Liu and Jordan:
Where the ratio of hourly diffuse to daily diffuse radiation is defined as follows:
The relationship between the ratio of hourly to daily diffuse radiation and the ratio of hourly to daily total radiation established by Gueymard is:
Taking into account the atmospheric extinction effect, Gueymard (Gueymard 2000) introduced two coefficients, a1 and a2:
The hourly global radiation on a horizontal surface is merely computed by:
The hourly direct solar radiation on a horizontal surface is defined by the equation:
The hourly beam radiation on a tilted surface is calculated as:
Models of radiation on a sloped surface
In order to perform the calculation of the global radiation gathered by a tilted collector at various angles and azimuth orientations, an isotropic and two anisotropic sky models were implemented in a Matlab code to obtain the maximum solar intensity and determine the corresponding angles in a comparative investigation.
The Liu and Jordan isotropic sky model
Assuming an isotropic sky, the Liu and Jordan model was used:
Anisotropic sky model
Some improved models for tilted surfaces take into account the circumsolar and horizon brightness radiation components. In this study, we employed two well-known models: the Perez model and the model of Hay, Davies, Klucher, and Reindl (HDKR). These models allow for evaluation of the global radiation on a sloping plane based on the Gueymard (2000) model for predicting the solar intensity on a horizontal surface. Indeed, according to Duffie and Beckman (2013) and Yadav and Chandel (2013), it is mentioned that the HDKR model delivers predictions approaching the measured values.
Perez et al. (1990) have developed a model based on detailed analysis, which takes into account the three diffuse components. So, the diffuse radiation on a sloped surface is expressed by:
where F1 and F2 are the circumsolar and horizon brightness coefficients, respectively.
The terms a and b account for the angles of incidence of the cone of circumsolar radiation, which are given by:
To compute the values of F1 and F2, first we need to calculate two parameters that describe the sky conditions: the clearness ε and the brightness Δ. The value of the clearness parameter allows us to select the Perez coefficients f11 to f23 from Table 2.
Coefficients of the Perez model.
| Range of ε | f 11 | f 12 | f 13 | f 21 | f 22 | f 23 |
|---|---|---|---|---|---|---|
| 1.000–1.065 | −0.008 | 0.588 | −0.062 | −0.060 | 0.072 | −0.022 |
| 1.065–1.230 | 0.130 | 0.683 | −0.151 | −0.019 | 0.066 | −0.029 |
| 1.230–1.500 | 0.330 | 0.487 | −0.221 | 0.055 | −0.064 | −0.026 |
| 1.500–1.950 | 0.568 | 0.187 | −0.295 | 0.109 | −0.152 | 0.014 |
| 1.950–2.800 | 0.873 | −0.392 | −0.362 | 0.226 | −0.462 | 0.001 |
| 2.800–4500 | 1.132 | −1.237 | −0.412 | 0.288 | −0.823 | 0.056 |
| 4.500–6.200 | 1.060 | −1.600 | −0.359 | 0.264 | −1.127 | 0.131 |
| 6.200–∞ | 0.678 | −0.327 | −0.250 | 0.156 | −1.377 | 0.251 |
Brightness coefficients for Perez’s anisotropic sky (Perez et al. 1990)
The HDKR model (Reindl, Beckman, and Duffie 1990) is more appropriate to predict global radiation on tilted surfaces towards the equator and yields results close to the measured values. According to the authors, the diffuse radiation is defined as follows:
Simulation and explanation of the results
The equations of the above-presented models have been computed under the Matlab code; curves are plotted giving the hourly irradiation intensity (IT) considering the monthly mean days (Table 1) of the year 2018.
Liu and Jordan model outcomes
The curves related to a unique azimuth angle and different inclinations of the solar collector are drawn in a single figure. Consequently, for each month, a group of four graphs is obtained according to the tested values (0°/22.5°/45°/67.5°) of the surface azimuth angle. Each figure contains seven curves of hourly solar intensities in relation with the chosen tilt angles (10°/15°/20°/25°/30°/35°/40°).
The simulation carried out in the city of Annaba for the whole year 2018, using the Gueymard daily integration (DI) model, allowed us to observe peaks of instantaneous radiation between noon and 2 PM. From the first group of curves, as illustrated by Figure 1, we note that the maximum radiation recorded in January is 370 W/m2. An inclination of 40° and an azimuthal surface angle (aw) equal to zero correspond to this case. These slope and orientation angles (40°, 0°) remain unchanged during February, but the maximum radiation recorded is around 590 W/m2 and at the same time the curve peaks are decreasing (Figure 2).

Monthly-average hourly global irradiation, January 17.

Monthly-average hourly global irradiation, February 16.
In examining the results for March, the maximum predicted irradiation value is 740 W/m2, corresponding to an orientation of 0° when the solar collector is tilted at 35° (Figure 3). For the other surface azimuth angles, there is a slight decrease in the radiated flux and the curves obtained are bell-shaped. The simulation of April displays a pinnacle of 1000 W/m2 at 12:30 PM, corresponding to an inclination of 25° and a surface azimuth angle of aw = 0° (Figure 4). Similar results were obtained in May. Panels inclined at 20–25° and oriented toward the south are expected to emit around 1000 W/m2 of radiation (Figure 5). Moreover, varying the panel orientation does not affect the energy collected over a wide range of tilts. Simulations of radiation during June revealed a maximum of about 860 W/m2 at 12:30 PM, obtained when the solar collector is tilted at 10° or 15° with a south-facing surface (Figure 6). Besides, for three orientations (22.5°/45°/67.5°), predictions show the same irradiation value while the curves tend to merge and move slightly to the right, as noticed in the previous months.

Monthly-average hourly global irradiation, March 16.

Monthly-average hourly global irradiation, April 15.

Monthly-average hourly global irradiation, May 15.

Monthly-average hourly global irradiation, June 11.
In July, the maximum radiation reaches 1020 W/m2 for a surface inclined at 15° and oriented toward the south. The curves have the same behavior as the previous ones, but they overlap in the afternoon when aw = 22.5° (Figure 7). It should be noted that the maximum intensity value of solar radiation remains almost the same for the considered orientations. In August, the predicted incident solar radiation is approximately 900 W/m2 when the panel is tilted 20° and oriented at aw = 0°. For other orientations, from 22.5° to 67.5°, the intensity of the incident solar flux decreases with increasing surface azimuth angle (Figure 8).

Monthly-average hourly global irradiation, July 17.

Monthly-average hourly global irradiation, August 16.
Obviously, in September, the solar rays decrease in intensity, as evidenced by the predicted maximum value of irradiation equal to 690 W/m2, obtained for an inclination of 30° and a full south orientation. One can note that the curves related to the angles aw = 22.5°, 45°, and 67.5° have the same shape as the above ones (Figure 9). Higher solar incident fluxes are obtained during October, compared to September. The predictions exhibit a maximum of 860 W/m2 for a tilted panel at 40° with full south orientation (Figure 10). However, increasing the surface azimuth angle results in a time shift of the optimal radiation curve to the right compared to the plotted curves of the first slope.

Monthly-average hourly global irradiation, September 15.

Monthly-average hourly global irradiation, October 15.
The simulation carried out for November (Figure 11) and December (Figure 12) gives maximum values of solar radiation of 645 W/m2 and 800 W/m2 respectively, collected on the panel inclined at 40° from the horizontal plane and oriented to the south (aw = 0°). The illustrations representing other surface azimuth angles (22.5°, 45°, and 67.5°) show a decrease in the value of the peaks and, at the same time, a shift of the optimal curve to the right, considering the curves obtained for other inclinations.

Monthly-average hourly global irradiation, November 14.

Monthly-average hourly global irradiation, December 10.
In Table 3 we summarize the results for the inclination and orientation angles for optimal adjustment of the solar collector and maximum radiation corresponding to the typical days of the year 2018. It is important to point out that the predictions reveal the highest solar intensity between 12 PM and 1 PM.
Maximum irradiation and optimal angles (aw = 0).
|
Monthly mean day
|
Jan. 17
|
Feb. 16
|
Mar. 16
|
Apr. 15
|
May 15
|
Jun. 11
|
| Maximum solar radiation, (W/m2) | 370 | 590 | 740 | 1000 | 1010 | 860 |
| Slope angle, β |
40° |
40° |
35° |
30° |
10–15° |
15° |
|
Monthly mean day
|
Jul. 17
|
Aug. 16
|
Sep. 15
|
Oct. 15
|
Nov. 14
|
Dec. 10
|
| Maximum solar radiation, (W/m2) | 1020 | 900 | 690 | 860 | 640 | 800 |
| Slope angle, β | 15° | 25° | 30° | 40° | 40° | 40° |
HDKR and Perez models’ outcomes
Concerning the simulations from the HDKR model, we chose to depict the maximum solar intensity at midday of the typical days versus tilt angle and drew curves of different azimuthal orientations for each month (Figures 13–18). The angle aw is measured in 5° increments from −15° to 55°.
The Table below (Table 4) summarizes the results obtained in the previous simulations.
Maximum global radiation on optimal monthly tilts and azimuth orientations.
| HDKR anisotropic | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Month | Jan. | Feb. | Mar. | Apr. | May | Jun. | Jul. | Aug. | Sep. | Oct. | Nov. | Dec. |
| Mean day | 17 | 16 | 16 | 15 | 15 | 11 | 17 | 16 | 15 | 15 | 14 | 10 |
| Max IT, (W/m2) | 455 | 692 | 819 | 1028 | 1023 | 869 | 1020 | 929 | 759 | 954 | 763 | 926 |
| β | 61 | 57 | 48° | 32° | 22° | 18° | 19° | 29° | 45° | 52° | 60° | 64° |
| a w | 5° | 5° | 0° | 0° | 0° | 15° | −5° | −5° | −5° | 0° | 0° | 5° |
|
|
||||||||||||
| Perez anisotropic | ||||||||||||
|
|
||||||||||||
| Max IT, (W/m2) | 435 | 675 | 822 | 1034 | 1029 | 880 | 1026 | 944 | 767 | 955 | 752 | 909 |
| β | 52 | 49 | 42 | 31 | 22 | 18 | 19 | 28 | 37 | 49 | 57 | 62 |
| a w | 5° | 5° | 0° | 0° | 0° | 15° | −5° | −5° | −5° | 0° | 0° | 5° |
The empirical relationships of two authors were used to compare and validate the results of the present work (Table 5). El-Kassaby (1988) established correlations to determine the optimal monthly tilt angle as a function of the month. The experimental work was carried out at the University of Mu’tah (Jordan), at a latitude of L = 31°. These relationships were applied to the city of Annaba to calculate the monthly optimal angles. In addition, one of the correlations of Tiris and Tiris (1998), namely Eq. (16), was implemented in the program to estimate the optimal monthly angle in the city of Annaba.
A comparison of the various works’ outcomes.
| Month | El-Kassaby | Tiris | This work | |||
|---|---|---|---|---|---|---|
| Liu and Jordan | Perez | HDKR | Average (Perez and HDKR) | |||
| Jan. | 64° | 63° | 40° | 52° | 61° | 56.5° |
| Feb. | 55° | 54° | 40° | 49° | 57° | 53° |
| Mar. | 40° | 39° | 35° | 42° | 48° | 45° |
| Apr. | 21° | 26° | 30° | 31° | 32° | 31.5° |
| May | 4° | 12° | 15° | 22° | 22° | 22° |
| Jun. | 0° | 3° | 15° | 18° | 18° | 18° |
| Jul. | 3° | 9° | 15° | 19° | 19° | 19° |
| Aug. | 14° | 18° | 25° | 28° | 29° | 28.5° |
| Sep. | 34° | 31° | 30° | 37° | 45° | 41° |
| Oct. | 51° | 52° | 40° | 49° | 52° | 50.5° |
| Nov. | 62° | 64° | 40° | 57° | 60° | 58.5° |
| Dec. | 66° | 73° | 40° | 62° | 64° | 63° |
Summary and conclusions
A simulation under a Matlab code was carried out for the performance prediction of inclined arrays in the hope of optimizing the solar collector positioning. On one hand, the Gueymard DI model associated with the simple isotropic relationship of Liu and Jordan was used. On the other hand, two more improved anisotropic models were investigated via the models of Perez and HDKR.
The graphical illustration of the results made it possible to follow the evolution of the hourly solar irradiation for the considered location and year during its daylight hours. Thanks to the wide-ranging curves, it was possible to identify the suitable inclination and orientation of the panel.
The approach considered in this case study facilitates the selection of the optimal monthly angle in each group and is more explicit in Figures 13–18. Visually, the highest curves correspond to the maximum radiation, which relates to the angles of inclination and azimuth, allowing the best performance of the solar collector. We could observe that when the surface azimuth angle increases, the curves move towards the afternoon, accompanied by a slight decrease in their peaks. This is mainly due to the direct component of the radiation on the inclined surface, which depends on the solar coordinates of the city of Annaba. Because of the term cos (as − aw) in Eq. (29), significant differences between the surface and solar azimuth angles result in a decrease in radiation and a shift of the bell-shape.

Maximum amounts of solar radiation (Jan. 17 and Feb. 16).

Maximum amounts of solar radiation (Mar. 16 and Apr. 15).

Maximum amounts of solar radiation (May 15 and June 11).

Maximum amounts of solar radiation (Jul. 17 and Aug. 16).

Maximum amounts of solar radiation (Sep. 15 and Oct. 15).

Maximum amounts of solar radiation (Nov. 14 and Dec. 10).
The maximum predicted value of solar radiation by the present simulation was 1020–1026 W/m2 in July for a panel tilted at 15–19°, and the minimum value was 370–455 W/m2 in January for a panel tilted at 40–61°. We conclude that, for optimal performance, the inclination β of the solar collector must be corrected monthly with a full-south orientation (aw = 0°), as defined in Tables 3 and 4. Furthermore, it was shown that the monthly mean hourly global radiation as a function of the monthly mean daily maximum possible number of sunshine hours is clearly dependent on latitude for high latitudes (Soler and Gopinathan 1994). This statement was evidenced by the results, particularly in autumn (Figures 9–12) and winter (Figures 1 and 2). In fact, the latitudinal effect was taken into account in the previous relationships and thus implies the cities that have different latitudes from Annaba city.
Finally, comparing the results of the Liu and Jordan model with the average results from the Perez and HDKR models, the following recommendations are put forward for Annaba:
β = 54° (L + 17°) is the recommended angle for the months between October and March. The models of Perez and HDKR are the best options to maximize the radiation collected because there will be significant radiation gain (26.7%) throughout this period.
β = 26° (L − 11°) is the recommended angle for the months between April and September. The model of Liu and Jordan and the models of Perez and HDKR are both the best options because of regularity and having constant radiation during the considered period.
-
Author contributions: All the authors have accepted responsibility for the entire content of this submitted manuscript and approved submission.
-
Research funding: None declared.
-
Conflict of interest statement: The authors declare no conflicts of interest regarding this article.
References
Collares-Pereira, M., and A. Rabl. 1979. “The Average Distribution of Solar Radiation-Correlations between Diffuse and Hemispherical and between Daily and Hourly Insolation Values.” Solar Energy 22 (2): 155–64, https://doi.org/10.1016/0038-092x(79)90100-2.Search in Google Scholar
Corrada, P., J. Bell, L. Guan, and N. Motta. 2014. “Optimizing Solar Collector Tilt Angle to Improve Energy Harvesting in a Solar Cooling System.” Energy Procedia 48: 806–12, https://doi.org/10.1016/j.egypro.2014.02.093.Search in Google Scholar
De Miguel, A., J. Bilbao, R. Aguiar, H. Kambezidis, and E. Negro. 2001. “Diffuse Solar Irradiation Model Evaluation in the North Mediterranean Belt Area.” Solar Energy 70 (2): 143–53, https://doi.org/10.1016/s0038-092x(00)00135-3.Search in Google Scholar
Duffie, J. A., and W. A. Beckman. 2013. Solar Engineering of Thermal Processes, 4th ed. Hoboken, New Jersey: John Wiley & Sons.10.1002/9781118671603Search in Google Scholar
El-Kassaby, M. M. 1988. “Monthly and Daily Optimum Tilt Angle for South Facing Solar Collectors; Theoretical Model, Experimental and Empirical Correlations.” Solar & Wind Technology 5 (6): 589–96, https://doi.org/10.1016/0741-983x(88)90054-9.Search in Google Scholar
Elminir, H. K., A. E. Ghitas, F. El-Hussainy, R. Hamid, M. M. Beheary, and K. M. Abdel-Moneim. 2006. “Optimum Solar Flat-Plate Collector Slope: Case Study for Helwan, Egypt.” Energy Conversion and Management 47 (5): 624–37, https://doi.org/10.1016/j.enconman.2005.05.015.Search in Google Scholar
Erbs, D. G., S. A. Klein, and J. A. Duffie. 1982. “Estimation of the Diffuse Radiation Fraction for Hourly, Daily and Monthly-Average Global Radiation.” Solar Energy 28 (4): 293–302, https://doi.org/10.1016/0038-092x(82)90302-4.Search in Google Scholar
Farahat, A., H. D. Kambezidis, M. Almazroui, and E. Ramadan. 2021. “Solar Potential in Saudi Arabia for Southward-Inclined Flat-Plate Surfaces.” Applied Sciences 11 (9): 4101–25, https://doi.org/10.3390/app11094101.Search in Google Scholar
Farahat, A., H. D. Kambezidis, M. Almazroui, and M. Al Otaibi. 2021. “Solar Potential in Saudi Arabia for Inclined Flat-Plate Surfaces of Constant Tilt Tracking the Sun.” Applied Sciences 11 (15): 7105–29, https://doi.org/10.3390/app11157105.Search in Google Scholar
Farahat, A., H. D. Kambezidis, M. Almazroui, and E. Ramadan. 2022. “Solar Energy Potential on Surfaces with Various Inclination Modes in Saudi Arabia: Performance of an Isotropic and an Anisotropic Model.” Applied Sciences 12 (11): 5356–76, https://doi.org/10.3390/app12115356.Search in Google Scholar
Frydrychowicz-Jastrzębska, G. 2011. “The Effect of Spatial Orientation of Solar Energy Receiver on the Energetic Gain.” Renewable Energies and Power Quality Journal 1 (9): 484–9, https://doi.org/10.24084/repqj09.367.Search in Google Scholar
Goswami, D. Y. 2015. Principles of Solar Engineering, 3rd ed. Boca Raton, Florida: Taylor & Francis Group, CRC Press.Search in Google Scholar
Gueymard, C. 2000. “Prediction and Performance Assessment of Mean Hourly Global Radiation.” Solar Energy 68 (3): 285–303, https://doi.org/10.1016/s0038-092x(99)00070-5.Search in Google Scholar
Handoyo, E. A., D. Ichsani, and Prabowo. 2013. “The Optimal Tilt Angle of a Solar Collector.” Energy Procedia 32: 166–75, doi:https://doi.org/10.1016/j.egypro.2013.05.022.Search in Google Scholar
Jamil Ahmad, M., and G. N. Tiwari. 2009. “Optimization of Tilt Angle for Solar Collector to Receive Maximum Radiation.” The Open Renewable Energy Journal 2: 19–24, https://doi.org/10.2174/1876387100902010019.Search in Google Scholar
Kacira, M., M. Simsek, Y. Babur, and S. Demirkol. 2004. “Determining Optimum Tilt Angles and Orientations of Photovoltaic Panels in Sanliurfa, Turkey.” Renewable Energy 29 (8): 1265–75, https://doi.org/10.1016/j.renene.2003.12.014.Search in Google Scholar
Kalogirou, S. A. 2014. Solar Energy Engineering Processes and Systems, 2nd ed. Waltham, Massachusetts: Academic Press, Elsevier.Search in Google Scholar
Kambezidis, H. D., and B. E. Psiloglou. 2021. “Estimation of the Optimum Energy Received by Solar Energy Flat-Plate Convectors in Greece Using Typical Meteorological Years. Part I: South-Oriented Tilt Angles.” Applied Sciences 11 (4): 1547–73, https://doi.org/10.3390/app11041547.Search in Google Scholar
Kambezidis, H. D., A. Farahat, M. Almazroui, and E. Ramadan. 2021. “Solar Potential in Saudi Arabia for Flat-Plate Surfaces of Varying Tilt Tracking the Sun.” Applied Sciences 11 (23): 11564–86, https://doi.org/10.3390/app112311564.Search in Google Scholar
Klein, S. A. 1977. “Calculation of Monthly Average Insolation on Tilted Surfaces.” Solar Energy 19 (4): 325–9, https://doi.org/10.1016/0038-092x(77)90001-9.Search in Google Scholar
Li, D. H. W., and T. N. T. Lam. 2007. “Determining the Optimum Tilt Angle and Orientation for Solar Energy Collection Based on Measured Solar Radiance Data.” International Journal of Photoenergy 2007: Article ID 085402, doi:https://doi.org/10.1155/2007/85402.Search in Google Scholar
Liu, B. Y. H., and R. C. Jordan. 1963. “The Long-Term Average Performance of Flat-Plate Solar-Energy Collectors: With Design Data for the U.S., its Outlying Possessions and Canada.” Solar Energy 7 (2): 53–74, https://doi.org/10.1016/0038-092x(63)90006-9.Search in Google Scholar
Mahmood, A. J. 2020. “Thermal Evaluation of a Double-Pass Unglazed Solar Air Heater with Perforated Plate and Wire Mesh Layers.” Sustainability 12: 3619, https://doi.org/10.3390/su12093619.Search in Google Scholar
Mzad, H. 2008. “Prediction of Thermal Performance of Double-Glazed Solar Collector.” Archives of Thermodynamics 29 (1): 69–84.Search in Google Scholar
Mzad, H., A. Otmani, A. Haouam, S. Łopata, and P. Ocłoń. 2018. “Tilt Optimization of a Double-Glazed Air Solar Collector Prototype.” MATEC Web of Conferences 240: 04006, https://doi.org/10.1051/matecconf/201824004006.Search in Google Scholar
Mzad, H., K. Bey, and R. Khelif. 2019. “Investigative Study of the Thermal Performance of a Trial Solar Air Heater.” Case Studies in Thermal Engineering 13: 100373, https://doi.org/10.1016/j.csite.2018.100373.Search in Google Scholar
Perez, R., P. Ineichen, R. Seals, J. Michalsky, and R. Stewart. 1990. “Modeling Daylight Availability and Irradiance Components from Direct and Global Irradiance.” Solar Energy 44 (55): 271–89, https://doi.org/10.1016/0038-092x(90)90055-h.Search in Google Scholar
PVGIS database website. 2018. Also available at: https://re.jrc.ec.europa.eu/pvg_tools/fr/#MR.Search in Google Scholar
Reindl, D. T., W. A. Beckman, and J. A. Duffie. 1990. “Evaluation of Hourly Tilted Surface Radiation Models.” Solar Energy 45 (1): 9–17, https://doi.org/10.1016/0038-092x(90)90061-g.Search in Google Scholar
Saedodin, S., S. A. H. Zamzamian, M. E. Nimvari, S. Wongwises, and H. J. Jouybari. 2017. “Performance Evaluation of a Flat-Plate Solar Collector Filled with Porous Metal Foam: Experimental and Numerical Analysis.” Energy Conversion and Management 153: 278–87, https://doi.org/10.1016/j.enconman.2017.09.072.Search in Google Scholar
Saxena, A., G. Srivastava, and V. Tirth. 2015. “Design and Thermal Performance Evaluation of a Novel Solar Air Heater.” Renewable Energy 77: 501–11, https://doi.org/10.1016/j.renene.2014.12.041.Search in Google Scholar
Soler, A., and K. K. Gopinathan. 1994. “Estimation of Monthly Mean Hourly Global Radiation for Latitudes in the 1°N–81°N Range.” Solar Energy 52 (3): 233–9, https://doi.org/10.1016/0038-092x(94)90489-8.Search in Google Scholar
Tang, R., and T. Wu. 2004. “Optimal Tilt-Angles for Solar Collectors Used in China.” Applied Energy 79 (3): 239–48, https://doi.org/10.1016/j.apenergy.2004.01.003.Search in Google Scholar
Tiris, M., and C. Tiris. 1998. “Optimum Collector Slope and Model Evaluation: Case Study for Gebze, Turkey.” Energy Conversion and Management 39 (3-4): 167–72, https://doi.org/10.1016/s0196-8904(96)00229-4.Search in Google Scholar
Yadav, A. K., and S. S. Chandel. 2013. “Tilt Angle Optimization to Maximize Incident Solar Radiation: A Review.” Renewable and Sustainable Energy Reviews 23: 503–13, https://doi.org/10.1016/j.rser.2013.02.027.Search in Google Scholar
© 2022 Walter de Gruyter GmbH, Berlin/Boston
Articles in the same Issue
- Frontmatter
- Review
- A comprehensive review on electric vehicles: charging and control techniques, electric vehicle-grid integration
- Research Articles
- Evaluation of parameters influencing the performance of photovoltaic-thermoelectric (PV-TE) hybrid system
- Dispatchable power supply from beam down solar point concentrator coupled to thermal energy storage and a Stirling engine
- Modelling, design and parametric analysis of a levitation based energy harvester
- Performance optimization of flywheel using experimental design approach
- Assessment and optimization of photovoltaic systems at the University Ibn Tofail according to the new law on renewable energy in Morocco using HOMER Pro
- Optimizing hybrid power system at highest sustainability
- Preparation of Na2HPO4⋅12H2O-based composite PCM and its application in air insulated box
- The efficiency of linear electromagnetic vibration-based energy harvester at resistive, capacitive and inductive loads
- A numerical investigation of optimum angles for solar energy receivers in the eastern part of Algeria
- Experimental investigation of soiling effects on the photovoltaic modules energy generation
- Frequency domain analysis of a piezoelectric energy harvester with impedance matching network
Articles in the same Issue
- Frontmatter
- Review
- A comprehensive review on electric vehicles: charging and control techniques, electric vehicle-grid integration
- Research Articles
- Evaluation of parameters influencing the performance of photovoltaic-thermoelectric (PV-TE) hybrid system
- Dispatchable power supply from beam down solar point concentrator coupled to thermal energy storage and a Stirling engine
- Modelling, design and parametric analysis of a levitation based energy harvester
- Performance optimization of flywheel using experimental design approach
- Assessment and optimization of photovoltaic systems at the University Ibn Tofail according to the new law on renewable energy in Morocco using HOMER Pro
- Optimizing hybrid power system at highest sustainability
- Preparation of Na2HPO4⋅12H2O-based composite PCM and its application in air insulated box
- The efficiency of linear electromagnetic vibration-based energy harvester at resistive, capacitive and inductive loads
- A numerical investigation of optimum angles for solar energy receivers in the eastern part of Algeria
- Experimental investigation of soiling effects on the photovoltaic modules energy generation
- Frequency domain analysis of a piezoelectric energy harvester with impedance matching network