Article Open Access

Diagnostic and prognostic value of quantitative detection of antimitochondrial antibodies subtype M2 using chemiluminescence immunoassay in primary biliary cholangitis

  • Miaochan Wang , Yujiao Jin and Aifang Xu EMAIL logo
Published/Copyright: September 5, 2023

To the Editor,

Primary biliary cholangitis (PBC) is an autoimmune liver disease characterized by cholestasis, disease-specific autoantibodies, and histologic evidence of chronic nonsuppurative destructive cholangitis affecting small or medium-sized bile ducts [1]. Without appropriate treatment, the disease can be progressive and lead to liver cirrhosis and liver failure [2]. Antimitochondrial antibody (AMA), the most specific autoantibody, is used as a serological marker for the diagnosis of PBC. The most specific subtype for PBC is the M2 subtype of AMA (AMA-M2) [2]. Indirect immunofluorescence (IIF) is the most common method for detecting AMA, using either rat triple-tissue sections (liver-kidney-stomach) or the HEp-2 cell line as substrates. Clinically, various methods are used to detect AMA-M2, such as enzyme-linked immunosorbent assay (ELISA), fluorescent bead-based assays, and line immunoassay (LIA). A previous meta-analysis found that both IIF-AMA and AMA-M2 have favorable accuracy for diagnosing PBC [3]. Moreover, combining the detection of IIF-AMA and AMA-M2 can achieve the highest sensitivity [4]. Chemiluminescence immunoassay has gained increasing attention in clinical diagnosis due to its high sensitivity, good specificity, wide linear range, and other desirable characteristics. However, research on the detection of AMA-M2 using chemiluminescence immunoassay is scarce. Therefore, we conducted a study to assess the diagnostic and prognostic value of quantitative detection of AMA-M2 using chemiluminescence immunoassay in PBC.

This study involved 158 PBC patients and 20 negative controls, including 5 cases each of alcoholic liver disease, hepatitis B, hepatitis C, and drug-induced liver injury. PBC was diagnosed according to the American Association for the Study of Liver Diseases (AASLD) guidelines [5]. AMA was detected using the Euroimmun test kit (EUROIMMUN, Germany) with rat kidneys as a substrate through IIF. PBC-related autoantibodies, such as AMA-M2, M2-3E, anti-Sp100, and anti-gp210 antibodies, were detected using the Euroimmune Test System (EUROIMMUN, Germany) through LIA. The discarded biological samples of these 178 patients were preserved and quantitatively detected for AMA-M2. Prior to reuse, the participants signed a consent form indicating their agreement to the reuse of their specimens for research purposes. This study was approved by the Ethics Committee of Hangzhou Xixi Hospital (2023048).

The iFlash-AMA-M2 assay (YHLO, China) and iFlash 3000 Chemiluminescence Immunoassay Analyzer (YHLO, China) were used to quantitatively determine AMA-M2 through chemiluminescent immunoassay. The iFlash-AMA-M2 assay is an indirect immunoassay that measures the chemiluminescent reaction as relative light units (RLUs). The amount of AMA-M2 in the sample is directly proportional to the RLUs detected by the iFlash optical system. Results are determined by using an instrument-specific calibration curve generated through a 3-point calibration and a master curve provided via the reagent QR code.

The area under the ROC curve for diagnosing PBC using iFlash-AMA-M2 was 0.842 (95 % CI 0.776–0.907). When a cut-off value of 13.5 AU/mL, corresponding to the highest Jordan Index, was used, the sensitivity and specificity were 66.5 and 95.0 %, respectively. According to the manual, nonreactive is defined as <16 AU/mL, indeterminate as ≥16 to <24 AU/mL, and reactive as ≥24 AU/mL. When a cut-off value of 16 AU/mL was used, the sensitivity and specificity were 63.9 and 95.0 %, respectively. Using a cut-off value of 20 AU/mL resulted in a sensitivity and specificity of 57.6 and 100 %, respectively. Lastly, when a cut-off value of 24 AU/mL was used, the sensitivity and specificity were 51.9 and 100 %, respectively.

The agreement between methods was assessed using the Kappa coefficient, with values ranging from 0 to 1. A Kappa value of 0–0.2 represents slight agreement, 0.2–0.4 represents fair agreement, 0.4–0.6 represents moderate agreement, 0.6–0.8 represents substantial agreement, and 0.8–0.9 represents excellent agreement. Table 1 shows agreement between iFlash-AMA-M2 and other AMA detection methods using various iFlash-AMA-M2 cutoff values (16, 20, and 24 AU/mL). At different cutoff values, iFlash-AMA-M2 and other AMA detection methods, including IIF and LIA, exhibited almost excellent agreement. At a cutoff value of 16 AU/mL, iFlash-AMA-M2 and M2-3E (LIA) showed the highest consistency with a value of 93.8 % and a Kappa coefficient of 0.874. Moreover, at a cutoff value of 24 AU/mL, iFlash-AMA-M2 had the highest agreement with AMA-M2 (LIA) at 88.2 % (kappa value of 0.756). One possible explanation for this phenomenon is that the chemiluminescence assay is more sensitive in detecting AMA-M2 than LIA. As shown in Supplementary Material, Table S1, increasing the cutoff value of iFlash-AMA-M2 converts false negative results of AMA-M2 (LIA) to true negative results, improving consistency between the two methods. In addition, even among the 76 patients classified as iFlash-AMA-M2 negative (<16 AU/mL) according to the manual, there were still 10 cases positive for IIF-AMA and 4 cases positive for M2-3E (LIA), with 3 cases positive for both. Supplemental Material, Table S2 demonstrates that combining multiple AMA detection methods can improve both the sensitivity and accuracy of AMA detection. Thus, in patients with suspected PBC, it may be necessary to combine multiple methods to improve the detection sensitivity of AMA.

Table 1:

Agreement between iFlash-AMA-M2 and other AMA detection methods using various iFlash-AMA-M2 cutoff values.

iFlash-AMA-M2 cutoff value, AU/mL Methods Agreement, % Kappa value
16 IIF-AMA 87.1 0.737
20 87.6 0.752
24 83.7 0.678
16 AMA-M2 (LIA) 75.8 0.540
20 82.0 0.643
24 88.2 0.756
16 M2-3E (LIA) 93.8 0.874
20 93.3 0.865
24 87.1 0.745

Of 158 PBC patients, there were 94 cases of liver cirrhosis and 64 cases without liver cirrhosis. Liver cirrhosis was diagnosed according to the Chinese guidelines on the management of liver cirrhosis [6]. Figure 1 shows the correlation between iFlash-AMA-M2 and logit-transformed cirrhosis incidence. The results indicated that iFlash-AMA-M2 was almost linear. Table 2 demonstrates that iFlash-AMA-M2 was significantly associated with the occurrence of liver cirrhosis as a continuous variable, as determined by performing logistic regression (OR: 1.008, 95 % CI: 1.004–1.013). Moreover, categorizing iFlash-AMA-M2 into a design variable (<20; 20–50; 50–200; >200 AU/mL), with <20 AU/mL as the reference group, an increasing trend of OR values was observed with an increase of iFlash-AMA-M2.

Figure 1: 
Relationship between iFlash-AMA-M2 and logit transformed cirrhosis incidence by using lowess smoothing technique.
Figure 1:

Relationship between iFlash-AMA-M2 and logit transformed cirrhosis incidence by using lowess smoothing technique.

Table 2:

Logistic regression analysis of the association between iFlash-AMA-M2 and cirrhosis.

Odds ratio 95 % CI
iFlash-AMA-M2, AU/mL 1.008 1.004–1.013 <0.001
iFlash-AMA-M2, AU/mL
<20 Reference
20–50 1.475 0.648–3.354 0.354
50–200 4.179 1.471–11.866 0.007
>200 20.893 4.609–94.713 <0.001
P for trend <0.001
  1. OR, odds ratio; CI, confidence interval.

In conclusion, our research found that the quantitative detection of AMA-M2 by chemiluminescence immunoassay has good diagnostic efficacy in the diagnosis of PBC, and good consistency with the detection results of IIF and LIA. Additionally, we found a significant correlation between AMA-M2 and the occurrence of liver cirrhosis in PBC patients.


Corresponding author: Aifang Xu, Department of Clinical Laboratory, Affiliated Hangzhou Xixi Hospital of Zhejiang University School of Medicine, Hengbu Street No. 2, Hangzhou 310023, Zhejiang, P.R. China, Fax: 86 0571 86481777, E-mail:

  1. Research ethics: This study was approved by the Ethics Committee of Hangzhou Xixi Hospital (2023048).

  2. Informed consent: Informed consent was obtained from all individuals included in this study, or their legal guardians or wards.

  3. Author contributions: The authors have accepted responsibility for the entire content of this manuscript and approved its submission.

  4. Competing interests: The authors state no conflict of interest.

  5. Research funding: None declared.

  6. Data availability: The raw data can be obtained on request from the corresponding author.

References

1. European Association for the Study of the Liver, Electronic address eee, European Association for the Study of the L. EASL clinical practice guidelines: the diagnosis and management of patients with primary biliary cholangitis. J Hepatol 2017;67:145–72. https://doi.org/10.1016/j.jhep.2017.03.022.Search in Google Scholar PubMed

2. Tanaka, A. Current understanding of primary biliary cholangitis. Clin Mol Hepatol 2021;27:1–21. https://doi.org/10.3350/cmh.2020.0028.Search in Google Scholar PubMed PubMed Central

3. Hu, S, Zhao, F, Wang, Q, Chen, WX. The accuracy of the anti-mitochondrial antibody and the M2 subtype test for diagnosis of primary biliary cirrhosis: a meta-analysis. Clin Chem Lab Med 2014;52:1533–42. https://doi.org/10.1515/cclm-2013-0926.Search in Google Scholar PubMed

4. Porcelli, B, Terzuoli, L, Bacarelli, MR, Cinci, F, Bizzaro, N. How reliable is the detection of anti-mitochondrial antibodies on murine triple-tissue? Clin Chem Lab Med 2020;58:e142–3. https://doi.org/10.1515/cclm-2019-1210.Search in Google Scholar PubMed

5. Lindor, KD, Bowlus, CL, Boyer, J, Levy, C, Mayo, M. Primary biliary cholangitis: 2018 practice guidance from the American association for the study of liver diseases. Hepatology 2019;69:394–419. https://doi.org/10.1002/hep.30145.Search in Google Scholar PubMed

6. Xu, XY, Ding, HG, Li, WG, Xu, JH, Han, Y, Jia, JD, et al.. Chinese guidelines on the management of liver cirrhosis (abbreviated version). World J Gastroenterol 2020;26:7088–103. https://doi.org/10.3748/wjg.v26.i45.7088.Search in Google Scholar PubMed PubMed Central


Supplementary Material

This article contains supplementary material (https://doi.org/10.1515/cclm-2023-0742).


Received: 2023-07-13
Accepted: 2023-08-26
Published Online: 2023-09-05
Published in Print: 2024-01-26

© 2023 the author(s), published by De Gruyter, Berlin/Boston

This work is licensed under the Creative Commons Attribution 4.0 International License.

Articles in the same Issue

  1. Frontmatter
  2. Editorial
  3. Rapid rule-in and rule-out protocols of acute myocardial infarction using hs-cTnI and hs-cTnT methods
  4. Reviews
  5. A guide to conducting systematic reviews of clinical laboratory tests
  6. Improving diagnosis and treatment of hypomagnesemia
  7. Opininon Paper
  8. Documenting and validating metrological traceability of serum alanine aminotransferase measurements: a priority for medical laboratory community for providing high quality service in hepatology
  9. EFLM Paper
  10. Assessing the status of European laboratories in evaluating biomarkers for chronic kidney diseases (CKD) and recommendations for improvement: insights from the 2022 EFLM Task Group on CKD survey
  11. General Clinical Chemistry and Laboratory Medicine
  12. Bland and Altman agreement method: to plot differences against means or differences against standard? An endless tale?
  13. Assessment of three equations to calculate plasma LDL cholesterol concentration in fasting and non-fasting hypertriglyceridemic patients
  14. Validation of metrological traceability of the new generation of Abbott Alinity alkaline phosphatase assay
  15. Quality assurance programs for vitamin A and E in serum: are we doing enough to assess laboratory performance?
  16. A supervised machine-learning approach for the efficient development of a multi method (LC-MS) for a large number of drugs and subsets thereof: focus on oral antitumor agents
  17. Performance evaluation of alternate ESR measurement method using BC-780 automated hematology analyzer: a comparison study with the Westergren reference method
  18. Total error in lymphocyte subpopulations by flow cytometry-based in state of the art using Spanish EQAS data
  19. Development and multi-center validation of a fully automated digital immunoassay for neurofilament light chain: toward a clinical blood test for neuronal injury
  20. CSF and plasma Aβ42/40 across Alzheimer’s disease continuum: comparison of two ultrasensitive Simoa® assays targeting distinct amyloid regions
  21. Improving regional medical laboratory center report quality through a report recall management system
  22. Cardiovascular Diseases
  23. Evaluation of the analytical and clinical performance of a new high-sensitivity cardiac troponin I assay: hs-cTnI (CLIA) assay
  24. Hemodialysis and biomarkers of myocardial infarction – a cohort study
  25. Letters to the Editor
  26. Chatbot GPT can be grossly inaccurate
  27. Blood collection in heparin vs. EDTA results in an inflammasome-independent increase in monocyte distribution width at 4 h
  28. Week-to-week within-subject and between-subject biological variation of copeptin
  29. The effect of unintended shortage in technical resources on the quality of endpoint clinical laboratory diagnosis
  30. Epigenetic signatures of cfDNA enable a topological assignment of tissue damage
  31. Six Sigma driven QC in antibody testing for infectious diseases
  32. Extensive analytical evaluation of the performances of the new DiaSys PCT assay and comparison with Elecsys B·R·A·H·M·S PCT test on Roche Cobas and B·R·A·H·M·S PCT-sensitive Kryptor
  33. Comment to: Extensive analytical evaluation of the performances of the new DiaSys PCT assay and comparison with Elecsys B·R·A·H·M·S PCT test on Roche Cobas and B·R·A·H·M·S PCT-sensitive Kryptor
  34. Evaluation of serum cortisol measurement by Ortho Vitro after stimulation by ACTH or insulin hypoglycaemia
  35. Diagnostic and prognostic value of quantitative detection of antimitochondrial antibodies subtype M2 using chemiluminescence immunoassay in primary biliary cholangitis
  36. Blood plasma biomarkers for Alzheimer’s disease: Aβ1–42/1–40 vs. AβX–42/X–40
Downloaded on 31.10.2025 from https://www.degruyterbrill.com/document/doi/10.1515/cclm-2023-0742/html
Scroll to top button