Some articles published in this issue of the Journal offer the opportunity to discuss further the important subject of standardization and harmonization in clinical laboratories. Both terms standardization and harmonization are often used interchangeably, because their final endpoint is basically identical, i.e., providing laboratory results to stakeholders (i.e., clinicians and patients) that could be compared across different laboratories, over time [1]. Although the importance of standardizing and/or harmonizing laboratory test results has been clear for four decades or more, adequate focus has only recently been given to the increasing need of pursuing these goals. Clinical laboratories can no longer work in isolation, and a wide effort is being proffered to foster standardization and harmonization in view of the challenges imposed by globalization, the historical need to improve patient safety and effectiveness of laboratory services, as well as for avoiding to reiterate unpractical recommendations that patients should always refer to the same laboratory for receiving equivalent results [2]. Nonetheless, these two terms reflect in their essence to different concepts. Standardization should be used when test results are uniform across routine measurement procedures and traceable to a recognized standard reference material defined by the International System of Units (SI) through a high-order primary reference material and/or a reference measurement procedure. Harmonization, is instead aimed to make test results more comparable irrespective of the analytical procedure, mainly because neither a reference measurement procedure (RPM) or a primary reference material (RM) are available [3]. Notably, this latter case involves the vast majority of the analytes measured in clinical laboratories, most of which represent an essential source of information for both clinical decision-making and patient care. It is hence increasingly clear that efforts should not only be made for developing further standardization initiatives, but also to assure comparability of laboratory results and information for those measurands for which no RMP neither RM were, are and will be available in the near future. In addition, standardization and harmonization initiatives should be promoted not only in the analytical phase, but throughout all other steps of the total testing process (TTP), thus improving quality and safety of laboratory information [4].
The first article published by Braga and Colleagues deals with definition and application of performance specifications for measurement uncertainty of 23 common laboratory tests [5]. Laboratories should, in fact, estimate and validate measurement uncertainty (MU) of the tests performed using analytical performance specifications (APS). The estimation of MU is a vital information in laboratory medicine, and is also an essential aspect for the accreditation of medical laboratories according to the ISO 15189:2012 standard [6]. The ISO Technical Specification 20914:2019 provides a guidance on how MU shall be estimated, using the so-called “top-down” approach which combines all sources of MU throughout the selected traceability chain [7]. In their work, the authors allocated 23 commonly ordered laboratory tests (i.e., measurands) to the models endorsed by the 2014 EFLM Strategic Conference, with the goal of precisely deriving APS for MU [8]: a) the outcome-based model (Model 1); b) the biological variation-based model (Model 2); and c) The Model 1 and 2 (a hybrid mode). The performance of commercial measuring systems used in their laboratory were then verified in order to establish whether the criteria could be fulfilled. Manufacturers were asked to provide metrological traceability information for identifying higher-order references (materials and/or procedures) used for assigning traceable values to their calibrators and obtaining a description of the applied calibration hierarchy. Therefore, this article could be seen as a very interesting and useful application of APS to define reliable MU in the context of metrological traceability for well-defined measurands. The second article authored by Dimech and colleagues address the problem of comparability in serology testing [9]. According to the authors, significant differences exist between the measurement of clinical chemistry analytes and serology of infectious diseases. In clinical chemistry, the measurand is typically an “inert chemical” (e.g., glucose, creatinine, sodium) with definite biochemical structure, molecular weight and almost invariable structure and composition over time. However, “when testing for antibodies, the test system is determining the binding of antibodies to a given antigen”. It is now universally recognized that patient samples with “low levels of antibodies but high affinity and avidity to a specific antigen, could have higher level of reactivity compared with a sample with high concentration of low-avidity antibodies” [9]. Therefore, the humoral response may considerably vary over time. Test systems for antibodies must account for this array of variables, highlighting the difference between infectious disease serology and testing for inert and highly stable analytes such as glucose or potassium, since measurands assayed with infectious disease serology are heterogenous and may also considerably vary using different test systems. In a previously published article, one of the authors of this paper concluded that “principles of standardization and control applied to clinical chemistry analytes cannot be used in infectious disease serology” [10]. The ongoing coronavirus disease 2019 (COVID-19) pandemic has magnified the differences in serology testing which are responsible for poor test results comparability, encompassing a large number of commercial available SARS-CoV-2 serological immunoassays which differ in terms of (a) antibody class detected (binding antibodies may include single immunoglobulins, their variable combinations, along with assays measuring “total” anti-SARS-Cov-2 antibodies); (b) target antigens (whole disrupted virus, aminoacid sequences of recombinant spike protein or its receptor binding domain, as well as of the nucleocapsid protein); (c) the continuously evolving structure of viral antigens, which may originate from one or more SARS-CoV-2 variants and/or sublineages; and (d) analytical procedure (e.g., later flow immunoassays, colorimetric microtiter enzyme immunoassays, fluorimetric or chemiluminescent immunoassays, plaque neutralization assays, and so forth).
Several efforts have been done made for improving comparability of anti-SARS-CoV-2 serological immunoassays, including development of the first, and more recently, the second WHO International Standard for anti-SARS-CoV-2 immunoglobulin and Reference Panel for antibodies to SARS-CoV-2 variants of concern (https://www.who.int/publications/m/item/who-bs-2022.2427). These two standards have been basically developed for being use with SARS-CoV-2 neutralization assays which (especially the plaque reduction neutralization test; PRNT), are still considered the gold standard. This types of “functional” tests must always be used for evaluating the agreement with antibody binding assays, in that the closer is the agreement, the more clinically valuable is the information delivered by each specific immunoassay. Serology testing is not the unique area of laboratory medicine that is experiencing serious challenges in adopting metrological traceability criteria: functionally specific assays are used for measuring some hormones and other measurands which may be characterized by heterogenous biochemical structure, and/or are composed by mixtures of different substances and isoforms (e.g., human chorionic gonadotropin, growth hormone, adiponectin, and even troponin I). Standardization and harmonization initiatives, therefore, must be carried out not only considering virtually “inert” clinical chemistry analytes, but also other measurands and areas of laboratory medicine, thus targeting analytical aspects together with all the other essential steps of the TTP that lead to the final generation of an “analytically reliable and clinically usable” test result [11]. According to our personal perspective, in fact, the final goal is not the “level of standardization” that could be achieved, but the possibility to make laboratory test results more “comparable” (that is, harmonization). Same concerns exist also for quality control systems, which may probably need different and more comprehensive approaches [12]. The heterogeneity of laboratory medicine, in terms of both measurands and analytical sectors, would require “personalized” approaches. The International Federations of Clinical Chemistry and Laboratory Medicine (namely IFCC and EFLM), as well as other scientific bodies, shall thus acknowledge the evidence that “we are no more clinical chemistry, but laboratory medicine professionals”. The Journal is and will remain an open platform for offering the opportunity to discuss these challenging subjects, tolerating different and even opposite, if not heretical, opinions.
-
Research funding: None declared.
-
Author contributions: All authors have accepted responsibility for the entire content of this manuscript and approved its submission.
-
Competing interests: Authors state no conflict of interest.
References
1. International consortium for harmonization of clinical laboratory results annual report 2021. Available from: https://www.harmonization.net/media/1165/ichclr-annual-report-2021.pdf [Accessed 28 Aug 2022].Search in Google Scholar
2. Plebani, M. Harmonization in laboratory medicine: more than clinical chemistry? Clin Chem Lab Med 2018;56:1579–86. https://doi.org/10.1515/cclm-2017-0865.Search in Google Scholar PubMed
3. Plebani, M. Harmonization in laboratory medicine: the complete picture. Clin Chem Lab Med 2013;51:741–51. https://doi.org/10.1515/cclm-2013-0075.Search in Google Scholar PubMed
4. Plebani, M. Towards a new paradigm in laboratory medicine: the five rights. Clin Chem Lab Med 2016;54:1881–91. https://doi.org/10.1515/cclm-2016-0848.Search in Google Scholar PubMed
5. Braga, F, Pasqualetti, S, Borrillo, F, Capoferri, A, Chibireva, M, Rovegno, L, et al.. Definition and application of performance specifications for measurement uncertainty of 23 common laboratory tests: linking theory to daily practice. Clin Chem Lab Med 2023;61:213–23. https://doi.org/10.1515/cclm-2022-0806.Search in Google Scholar PubMed
6. ISO 15189: 2012. Medical laboratories: requirements for quality and competence, 3rd ed. Geneva: ISO; 2012.Search in Google Scholar
7. ISO/TS 20914: 2019. Medical laboratories: practical guidance for the estimation of measurement uncertainty, 1st ed. Geneva: ISO; 2019.Search in Google Scholar
8. Sandberg, S, Fraser, CG, Horvath, AR, Jansen, R, Jones, G, Oosterhuis, W, et al.. Defining analytical performance specifications: consensus statement from the 1st strategic conference of the European federation of clinical chemistry and laboratory medicine. Clin Chem Lab Med 2015;53:833–5. https://doi.org/10.1515/cclm-2015-0067.Search in Google Scholar PubMed
9. Dimech, WJ, Vincini, GA, Plebani, M, Lippi, G, Nichols, JH, Sonntag, O. Time to address quality control processes applied to antibody testing for infectious diseases. Clin Chem Lab Med 2023;61:205–12.10.1515/cclm-2022-0986Search in Google Scholar PubMed
10. Dimech, W. The standardization and control of serology and nucleic acid testing for infectious diseases. Clin Microbiol Rev 2021;34:e0003521. https://doi.org/10.1128/CMR.00035-21.Search in Google Scholar PubMed PubMed Central
11. Lippi, G, Plebani, M. A modern and pragmatic definition of laboratory medicine. Clin Chem Lab Med 2020;58:1171. https://doi.org/10.1515/cclm-2020-0114.Search in Google Scholar PubMed
12. Plebani, M, Gillery, P, Greaves, RF, Lackner, KJ, Lippi, G, Melichar, B, et al.. Rethinking internal quality control: the time is now. Clin Chem Lab Med 2022;60:1316–7. https://doi.org/10.1515/cclm-2022-0587.Search in Google Scholar PubMed
© 2022 the author(s), published by De Gruyter, Berlin/Boston
This work is licensed under the Creative Commons Attribution 4.0 International License.
Articles in the same Issue
- Frontmatter
- Editorial
- Standardization and harmonization in laboratory medicine: not only for clinical chemistry measurands
- Mini Review
- The effect of the immunoassay curve fitting routine on bias in troponin
- Opinion Papers
- An overview of the most important preanalytical factors influencing the clinical performance of SARS-CoV-2 antigen rapid diagnostic tests (Ag-RDTs)
- Time to address quality control processes applied to antibody testing for infectious diseases
- Perspectives
- Definition and application of performance specifications for measurement uncertainty of 23 common laboratory tests: linking theory to daily practice
- The gaps between the new EU legislation on in vitro diagnostics and the on-the-ground reality
- General Clinical Chemistry and Laboratory Medicine
- Second-generation Elecsys cerebrospinal fluid immunoassays aid diagnosis of early Alzheimer’s disease
- Evaluation of the interchangeability between the new fully-automated affinity chrome-mediated immunoassay (ACMIA) and the Quantitative Microsphere System (QMS) with a CE-IVD-certified LC-MS/MS assay for therapeutic drug monitoring of everolimus after solid organ transplantation
- Quantitative detection of anti-PLA2R antibodies targeting different epitopes and its clinical application in primary membranous nephropathy
- Reference Values and Biological Variations
- A zlog-based algorithm and tool for plausibility checks of reference intervals
- Harmonization of indirect reference intervals calculation by the Bhattacharya method
- Red blood cell parameters in early childhood: a prospective cohort study
- Cancer Diagnostics
- Association of circulating free and total oxysterols in breast cancer patients
- Effect of short-term storage of blood samples on gene expression in lung cancer patients
- Infectious Diseases
- Operation Moonshot: rapid translation of a SARS-CoV-2 targeted peptide immunoaffinity liquid chromatography-tandem mass spectrometry test from research into routine clinical use
- Seroprevalence of SARS-CoV-2 antibodies in Italy in newborn dried blood spots
- Positivization time of a COVID-19 rapid antigen self-test predicts SARS-CoV-2 viral load: a proof of concept
- New insights into SARS-CoV-2 Lumipulse G salivary antigen testing: accuracy, safety and short TAT enhance surveillance
- Preanalytical stability of SARS-CoV-2 anti-nucleocapsid antibodies
- Prognostic value of procalcitonin in cancer patients with coronavirus disease 2019
- 24/7 workflow for bloodstream infection diagnostics in microbiology laboratories: the first step to improve clinical management
- Diagnostic performance of machine learning models using cell population data for the detection of sepsis: a comparative study
- Diagnostic value of procalcitonin, hypersensitive C-reactive protein and neutrophil-to-lymphocyte ratio for bloodstream infections in pediatric tumor patients
- Letters to the Editor
- Pseudohyponatremia: interference of hyperglycemia on indirect potentiometry
- Ligand binding assay-related underestimation of 25-hydroxyvitamin D in pregnant women exaggerates the prevalence of vitamin D insufficiency
- Urokinase-type plasminogen activator soluble receptor (suPAR) assay in clinical routine: evaluation one year after its introduction in the high automation corelab of the A. Gemelli hospital
- Is this a true lambda free light chain?
- Effect of various blood collection tubes on serum lithium and other electrolytes: our perspective from a tertiary healthcare institute
Articles in the same Issue
- Frontmatter
- Editorial
- Standardization and harmonization in laboratory medicine: not only for clinical chemistry measurands
- Mini Review
- The effect of the immunoassay curve fitting routine on bias in troponin
- Opinion Papers
- An overview of the most important preanalytical factors influencing the clinical performance of SARS-CoV-2 antigen rapid diagnostic tests (Ag-RDTs)
- Time to address quality control processes applied to antibody testing for infectious diseases
- Perspectives
- Definition and application of performance specifications for measurement uncertainty of 23 common laboratory tests: linking theory to daily practice
- The gaps between the new EU legislation on in vitro diagnostics and the on-the-ground reality
- General Clinical Chemistry and Laboratory Medicine
- Second-generation Elecsys cerebrospinal fluid immunoassays aid diagnosis of early Alzheimer’s disease
- Evaluation of the interchangeability between the new fully-automated affinity chrome-mediated immunoassay (ACMIA) and the Quantitative Microsphere System (QMS) with a CE-IVD-certified LC-MS/MS assay for therapeutic drug monitoring of everolimus after solid organ transplantation
- Quantitative detection of anti-PLA2R antibodies targeting different epitopes and its clinical application in primary membranous nephropathy
- Reference Values and Biological Variations
- A zlog-based algorithm and tool for plausibility checks of reference intervals
- Harmonization of indirect reference intervals calculation by the Bhattacharya method
- Red blood cell parameters in early childhood: a prospective cohort study
- Cancer Diagnostics
- Association of circulating free and total oxysterols in breast cancer patients
- Effect of short-term storage of blood samples on gene expression in lung cancer patients
- Infectious Diseases
- Operation Moonshot: rapid translation of a SARS-CoV-2 targeted peptide immunoaffinity liquid chromatography-tandem mass spectrometry test from research into routine clinical use
- Seroprevalence of SARS-CoV-2 antibodies in Italy in newborn dried blood spots
- Positivization time of a COVID-19 rapid antigen self-test predicts SARS-CoV-2 viral load: a proof of concept
- New insights into SARS-CoV-2 Lumipulse G salivary antigen testing: accuracy, safety and short TAT enhance surveillance
- Preanalytical stability of SARS-CoV-2 anti-nucleocapsid antibodies
- Prognostic value of procalcitonin in cancer patients with coronavirus disease 2019
- 24/7 workflow for bloodstream infection diagnostics in microbiology laboratories: the first step to improve clinical management
- Diagnostic performance of machine learning models using cell population data for the detection of sepsis: a comparative study
- Diagnostic value of procalcitonin, hypersensitive C-reactive protein and neutrophil-to-lymphocyte ratio for bloodstream infections in pediatric tumor patients
- Letters to the Editor
- Pseudohyponatremia: interference of hyperglycemia on indirect potentiometry
- Ligand binding assay-related underestimation of 25-hydroxyvitamin D in pregnant women exaggerates the prevalence of vitamin D insufficiency
- Urokinase-type plasminogen activator soluble receptor (suPAR) assay in clinical routine: evaluation one year after its introduction in the high automation corelab of the A. Gemelli hospital
- Is this a true lambda free light chain?
- Effect of various blood collection tubes on serum lithium and other electrolytes: our perspective from a tertiary healthcare institute