Abstract
Background: Errors in the transfusion process can compromise patient safety. A study was undertaken at our center to identify the errors in the transfusion process and their causes in order to reduce their occurrence by corrective and preventive actions.
Methods: All near miss, no harm events and adverse events reported in the ‘transfusion process’ during 1 year study period were recorded, classified and analyzed at a tertiary care teaching hospital in North India.
Results: In total, 285 transfusion related events were reported during the study period. Of these, there were four adverse (1.5%), 10 no harm (3.5%) and 271 (95%) near miss events. Incorrect blood component transfusion rate was 1 in 6031 component units. ABO incompatible transfusion rate was one in 15,077 component units issued or one in 26,200 PRBC units issued and acute hemolytic transfusion reaction due to ABO incompatible transfusion was 1 in 60,309 component units issued. Fifty-three percent of the antecedent near miss events were bedside events. Patient sample handling errors were the single largest category of errors (n=94, 33%) followed by errors in labeling and blood component handling and storage in user areas.
Conclusions: The actual and near miss event data obtained through this initiative provided us with clear evidence about latent defects and critical points in the transfusion process so that corrective and preventive actions could be taken to reduce errors and improve transfusion safety.
©2012 by Walter de Gruyter Berlin Boston
Articles in the same Issue
- Congress Abstracts
- 44th National Congress of the Italian Society of Clinical Biochemistry and Clinical Molecular Biology
- Masthead
- Masthead
- Editorials
- Tumor biomarkers: PSA and beyond
- Error reporting in transfusion medicine: an important tool to improve patient safety
- The measurement of 25-hydroxy vitamin D – an analytical challenge
- Reviews
- Kallikrein-related peptidases (KLKs): a gene family of novel cancer biomarkers
- Exhaled breath analysis for early cancer detection: principle and progress in direct mass spectrometry techniques
- γ′ Fibrinogen as a novel marker of thrombotic disease
- Mini Review
- Revaluating serum ferritin as a marker of body iron stores in the traceability era
- Genetics and Molecular Diagnostics
- Association of PBEF gene polymorphisms with acute lung injury, sepsis, and pneumonia in a northeastern Chinese population
- General Clinical Chemistry and Laboratory Medicine
- Brazilian laboratory indicators program
- Error reporting in transfusion medicine at a tertiary care centre: a patient safety initiative
- Application of mathematical models of system uncertainty to evaluate the utility of assay calibration protocols
- 25-Hydroxyvitamin D testing: challenging the performance of current automated immunoassays
- Analytical validation of the Roche 25-OH Vitamin D Total assay
- The new Roche Vitamin D Total assay: fit for its purpose?
- Improvement of a prenatal screening program for trisomy 18 in the first trimester of gestation
- Stability of osteopontin in plasma and serum
- Is there a suitable point-of-care glucose meter for tight glycemic control? Evaluation of one home-use and four hospital-use meters in an intensive care unit
- Cancer Diagnostics
- Rapid elimination kinetics of free PSA or human kallikrein-related peptidase 2 after initiation of gonadotropin-releasing hormone-antagonist treatment of prostate cancer: potential for rapid monitoring of treatment responses
- Detection of frequent ABCB1 polymorphisms by high-resolution melting curve analysis and their effect on breast carcinoma prognosis
- Cardiovascular Diseases
- The combined use of neutrophil gelatinase-associated lipocalin and brain natriuretic peptide improves risk stratification in pediatric cardiac surgery
- Association of the atherogenic index of plasma and oxidative stress status with weight gain during non-complicated pregnancy
- The high-sensitivity cardiac troponin T assay is superior to its previous assay generation for prediction of 90-day clinical outcome in ischemic stroke
- Letters to the Editor
- Evaluation of the cross-reactivity of 25-hydroxyvitamin D2 on seven commercial immunoassays on native samples
- Measurement of 25-hydroxyvitamin vitamin D by liquid chromatography tandem-mass spectrometry with comparison to automated immunoassays
- Analytical evaluation of a new automated protein binding assay to determine 25-hydroxyvitamin D concentrations
- Mindray BS-800M1: a new clinical chemistry system with a flexible technology meeting quality performances
- Association of urinary albumin and serum high molecular weight-adiponectin with metabolic syndrome in patients with essential hypertension
- Measurement of nitrite in plasma and serum: still a challenging analytical task
- Association between serum γ-glutamyltransferase and pulmonary dysfunction
- Serum ferritin concentrations predict incidence of metabolic syndrome in rural Korean adults
- Homocysteine, folic acid and vitamin B12 levels in females with severe acne vulgaris
Articles in the same Issue
- Congress Abstracts
- 44th National Congress of the Italian Society of Clinical Biochemistry and Clinical Molecular Biology
- Masthead
- Masthead
- Editorials
- Tumor biomarkers: PSA and beyond
- Error reporting in transfusion medicine: an important tool to improve patient safety
- The measurement of 25-hydroxy vitamin D – an analytical challenge
- Reviews
- Kallikrein-related peptidases (KLKs): a gene family of novel cancer biomarkers
- Exhaled breath analysis for early cancer detection: principle and progress in direct mass spectrometry techniques
- γ′ Fibrinogen as a novel marker of thrombotic disease
- Mini Review
- Revaluating serum ferritin as a marker of body iron stores in the traceability era
- Genetics and Molecular Diagnostics
- Association of PBEF gene polymorphisms with acute lung injury, sepsis, and pneumonia in a northeastern Chinese population
- General Clinical Chemistry and Laboratory Medicine
- Brazilian laboratory indicators program
- Error reporting in transfusion medicine at a tertiary care centre: a patient safety initiative
- Application of mathematical models of system uncertainty to evaluate the utility of assay calibration protocols
- 25-Hydroxyvitamin D testing: challenging the performance of current automated immunoassays
- Analytical validation of the Roche 25-OH Vitamin D Total assay
- The new Roche Vitamin D Total assay: fit for its purpose?
- Improvement of a prenatal screening program for trisomy 18 in the first trimester of gestation
- Stability of osteopontin in plasma and serum
- Is there a suitable point-of-care glucose meter for tight glycemic control? Evaluation of one home-use and four hospital-use meters in an intensive care unit
- Cancer Diagnostics
- Rapid elimination kinetics of free PSA or human kallikrein-related peptidase 2 after initiation of gonadotropin-releasing hormone-antagonist treatment of prostate cancer: potential for rapid monitoring of treatment responses
- Detection of frequent ABCB1 polymorphisms by high-resolution melting curve analysis and their effect on breast carcinoma prognosis
- Cardiovascular Diseases
- The combined use of neutrophil gelatinase-associated lipocalin and brain natriuretic peptide improves risk stratification in pediatric cardiac surgery
- Association of the atherogenic index of plasma and oxidative stress status with weight gain during non-complicated pregnancy
- The high-sensitivity cardiac troponin T assay is superior to its previous assay generation for prediction of 90-day clinical outcome in ischemic stroke
- Letters to the Editor
- Evaluation of the cross-reactivity of 25-hydroxyvitamin D2 on seven commercial immunoassays on native samples
- Measurement of 25-hydroxyvitamin vitamin D by liquid chromatography tandem-mass spectrometry with comparison to automated immunoassays
- Analytical evaluation of a new automated protein binding assay to determine 25-hydroxyvitamin D concentrations
- Mindray BS-800M1: a new clinical chemistry system with a flexible technology meeting quality performances
- Association of urinary albumin and serum high molecular weight-adiponectin with metabolic syndrome in patients with essential hypertension
- Measurement of nitrite in plasma and serum: still a challenging analytical task
- Association between serum γ-glutamyltransferase and pulmonary dysfunction
- Serum ferritin concentrations predict incidence of metabolic syndrome in rural Korean adults
- Homocysteine, folic acid and vitamin B12 levels in females with severe acne vulgaris