Home Serum cystatin C is an early biomarker for assessment of renal function in burn patients
Article
Licensed
Unlicensed Requires Authentication

Serum cystatin C is an early biomarker for assessment of renal function in burn patients

  • Xiaoyan Cai , Zhaolin Long EMAIL logo , Lianduo Lin , Yudong Feng , Naxi Zhou and Qifeng Mai
Published/Copyright: January 19, 2012

Abstract

Background: Early detection of renal dysfunction is important in burn patients. This study evaluated whether serum cystatin C (CysC) is a potentially accurate and sensitive marker for identification of reduced glomerular filtration rate (GFR) and the risk factors of impaired renal function in major burn patients.

Methods: A total of 48 adult patients with major burn injury were enrolled. Renal function was assessed using serum creatinine (sCr), 24-h urinary creatinine clearance (24-hCrCl), sCr-based formulae and CysC-based formulae on the second day and seventh day post-burn.

Results: There was a high prevalence (27.1%) of acute impaired renal function in major burn patients in the first week post-burn. CysC-based formulae for estimated GFR (eGFR) are more accurate and sensitive for detection of impaired renal function than sCr-based formulae. Multivariate logistic regression analysis demonstrated that age (OR, 2.08; 95% CI 1.26–4.77) and the percentage of burn area (OR, 3.41; 95% CI 1.64–6.95) were independent risk factors of impaired renal function.

Conclusions: The results of this study suggest that CysC is a more accurate and sensitive marker for identification of acute impaired renal function in major burn patients than sCr. It is important to measure CysC and calculate eGFR to prevent acute renal failure and modify drug doses in burn patients, especially those of older age and with major burn areas.


Corresponding author: Professor Zhaolin Long, Department of Urology, the First People’s Hospital of Shunde (The Affiliated Hospital at Shunde, Southern Medical University), Penglai Road, Daliang Town, Shunde District, Foshan, Guangdong 528300, P.R. China Phone: +86 757 22318701, Fax: +86 757 22223899

Received: 2011-11-19
Accepted: 2011-12-2
Published Online: 2012-01-19
Published in Print: 2012-04-01

©2012 by Walter de Gruyter Berlin Boston

Articles in the same Issue

  1. A sensitive quantitative test strip based point-of-care albuminuria screening assay
  2. Editorials
  3. Serum biomarkers for the non-invasive diagnosis of liver fibrosis: the importance of being validated
  4. Primary blood tubes mixing: time for updated recommendations
  5. Reviews
  6. 10.1515/cclm-2011-0847
  7. The hCG assay or pregnancy test
  8. Mini Reviews
  9. The role of mean platelet volume in predicting thrombotic events
  10. The role of red blood cell distribution width in cardiovascular and thrombotic disorders
  11. Genetics and Molecular Diagnostics
  12. Comparison of different collection procedures and two methods for DNA isolation from saliva
  13. Detection of α-globin gene deletion and duplication using quantitative multiplex PCR of short fluorescent fragments
  14. High-throughput detection, genotyping and quantification of the human papillomavirus using real-time PCR
  15. General Clinical Chemistry and Laboratory Medicine
  16. Quantification of human serum insulin concentrations in clinical pharmacokinetic or bioequivalence studies: what defines the “best method”?
  17. Serum cystatin C is an early biomarker for assessment of renal function in burn patients
  18. 10.1515/cclm.2011.0849
  19. Mid-stream vs. first-voided urine collection by using automated analyzers for particle examination in healthy subjects: an Italian multicenter study
  20. Percentage of hypochromic erythrocytes as a potential marker of iron availability
  21. Laboratory evaluation of a flow cytometric BCR-ABL immunobead assay
  22. Validation and Outcome Studies
  23. Independent validation of the Enhanced Liver Fibrosis (ELF) score in the ANRS HC EP 23 Fibrostar cohort of patients with chronic hepatitis C
  24. Cancer Diagnostics
  25. Demasking of epithelial cell adhesion molecule (EpCAM) on circulating epithelial tumor cells by Tween®20 treatment in breast cancer patients
  26. Anti-thyroid peroxidase antibodies are associated with the absence of distant metastases in patients with newly diagnosed breast cancer
  27. Blood presence of circulating oncofetal fibronectin mRNA, by RT-PCR, does not represent a useful specific marker for the management and follow-up of thyroid cancer patients
  28. Serum mesothelin and megakaryocyte potentiating factor in pancreatic and biliary cancers
  29. Cardiovascular Diseases
  30. The performance of high sensitivity troponin for the diagnosis of acute myocardial infarction is underestimated
  31. The prognostic value of N-terminal pro-brain natriuretic peptide in non-ST elevation acute coronary syndromes: a meta-analysis
  32. Measurement of high-molecular-weight adiponectin is not useful in assessing coronary stenosis
  33. Letters to the Editor
  34. Serum concentration of neopterin on admission does not improve the diagnostic performance of highly-sensitive troponin I
  35. Evaluation of the interference by homogentisic acid and other organic acids on the enzymatic and Jaffé method creatinine assay
  36. A comparative analysis of the Iris iQ200 with manual microscopy as a diagnostic tool for dysmorphic erythrocytes in urine
  37. Falsely decreased ionized calcium results due to analytical interference by teriflunomide, the active metabolite of leflunomide (Arava®)
  38. Is polyethylene glycol precipitation of hyperprolactinaemic samples required when using the Beckman Coulter DxI-800 prolactin assay?
  39. Congress Abstracts
  40. ISMD2012: Ninth International Symposium on Molecular Diagnostics
  41. ArabMedLab Marrakech 2012
  42. Masthead
  43. Masthead
Downloaded on 7.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/cclm-2011-0838/html
Scroll to top button