Home Positive predictive value of serological diagnostic measures in celiac disease
Article
Licensed
Unlicensed Requires Authentication

Positive predictive value of serological diagnostic measures in celiac disease

  • Peter Toftedal , Christian Nielsen , Jonas Trolle Madsen , Kjell Titlestad , Steffen Husby and Søren Thue Lillevang
Published/Copyright: March 5, 2010

Abstract

Background: Celiac disease (CD) antibodies, immunoglobulin A (IgA) anti-tissue transglutaminase (anti-tTG), IgA endomysium antibody (EMA), IgA and IgG anti-gliadin antibodies (IgA and IgG AGA) are first-line diagnostic tools used in selecting patients for duodenal biopsy. The goal of this study was to evaluate the diagnostic quality of serological testing for CD.

Methods: CD serological tests (IgA and IgG AGA, anti-tTG and EMA) from 11,915 individuals were measured. Data were combined with clinical data and results of duodenal biopsy using a unique Danish personal identification number.

Results: The positive predictive value (PPV) varied according to different combinations of positive CD antibodies, being highest when all antibodies were positive (97.6%). The anti-tTG concentration correlated strongly with EMA positivity, number of additional positive antibodies, and higher PPV. A logistic regression model predicted the probability of later biopsy-proven CD in relation to concentrations of IgA AGA and anti-tTG at initial serological screening.

Conclusions: The anti-tTG concentration at initial serological CD screening was highly informative in relation to EMA positivity, number of additional CD specific antibodies and PPV. Furthermore, in the high-risk group of patients investigated, the concentrations of anti-tTG and IgA AGA at initial serological screening could accurately predict the probability of future biopsy-proven CD.

Clin Chem Lab Med 2010;48:685–91.


Corresponding author: Søren Thue Lillevang, Department of Clinical Immunology, Odense University Hospital, Sdr. Boulevard 29, 5000 Odense C, Denmark Phone: +45 65411688, Fax: +45 66127975,

Received: 2009-10-12
Accepted: 2010-1-11
Published Online: 2010-03-5
Published in Print: 2010-05-01

©2010 by Walter de Gruyter Berlin New York

Articles in the same Issue

  1. Editorials
  2. Laboratory medicine and natural disasters: are we ready for the challenge?
  3. Reference values: still a critical issue in laboratory medicine
  4. Review
  5. Contemporary platelet function testing
  6. Minireviews
  7. Disasters: where they find us
  8. Inter-laboratory variation in cerebrospinal fluid biomarkers for Alzheimer's disease: united we stand, divided we fall
  9. Opinion Paper
  10. Glycated hemoglobin (HbA1c): old dogmas, a new perspective?
  11. Guidelines and Recommendations
  12. IFCC reference procedures for measurement of the catalytic concentrations of enzymes: corrigendum, notes and useful advice
  13. Recommendations for the implementation of international standardization of glycated hemoglobin in Italy
  14. Genetics and Molecular Diagnostics
  15. UGT2B17 and SULT1A1 gene copy number variation (CNV) detection by LabChip microfluidic technology
  16. Genetic polymorphisms of CYP1A2, CYP3A4, CYP3A5, pregnane/steroid X receptor and constitutive androstane receptor in 207 healthy Spanish volunteers
  17. Automated genomic DNA extraction from saliva using the QIAxtractor
  18. General Clinical Chemistry and Laboratory Medicine
  19. A new statistical method for evaluating long-term analytical performance of laboratories applied to an external quality assessment scheme for flow cytometry
  20. Evaluation of the Becton-Dickinson rapid serum tube: does it provide a suitable alternative to lithium heparin plasma tubes?
  21. Immunoglobulin M antibodies to aquaporin-4 in neuromyelitis optica and related disorders
  22. Evaluation of the new body fluid mode on the Sysmex XE-5000 for counting leukocytes and erythrocytes in cerebrospinal fluid and other body fluids
  23. Extracellular haemoglobin, oxidative stress and quality of red blood cells relative to perioperative blood salvage
  24. Positive predictive value of serological diagnostic measures in celiac disease
  25. Retinol potentiates the inhibitory effect of ascorbic acid on uric acid assay
  26. Reference Values and Biological Variations
  27. Reference intervals for brain natriuretic peptide in healthy newborns and infants measured with an automated immunoassay platform
  28. Factors influencing serum total tryptase concentrations in a general adult population
  29. Leptin and adiponectin levels in pubertal children: relationship with anthropometric variables and body composition
  30. Cardiovascular risk factors and γ-glutamyltransferase fractions in healthy individuals
  31. Cancer Diagnostics
  32. Combined analysis of survivin autoantibody and carcinoembryonic antigen biomarkers for improved detection of colorectal cancer
  33. Oligoclonal bands and immunoglobulin isotype switch during monitoring of patients with multiple myeloma and autologous hematopoietic cell transplantation: a 16-year experience
  34. Letters to the Editor
  35. Methodological weakness in using correlation coefficients for assessing the interchangeability of analyte data between samples collected under different sampling conditions – the example of matrix metalloproteinase 9 determined in serum and plasma samples
  36. Intralipid causes falsely increased glucose concentrations with the Hemocue glucose analyzer
  37. Serum cholesterol: required and actual bias values
  38. Abstracts
  39. ISMD2010 Eighth International Symposium on Molecular Diagnostics
Downloaded on 6.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2010.136/pdf