Home A new statistical method for evaluating long-term analytical performance of laboratories applied to an external quality assessment scheme for flow cytometry
Article
Licensed
Unlicensed Requires Authentication

A new statistical method for evaluating long-term analytical performance of laboratories applied to an external quality assessment scheme for flow cytometry

  • Wim Coucke , Marjan Van Blerk , Jean-Claude Libeer , Christel Van Campenhout and Adelin Albert
Published/Copyright: February 17, 2010

Abstract

Background: The Belgian External Quality Assessment Scheme for Flow Cytometry evaluates the long-term analytical performance of participating laboratories by calculating a regression line between the target and reported values of each parameter for each laboratory during the past 3 years. This study aims to develop a method to find laboratories with aberrant variability or bias using robust techniques and to obtain robust estimates of the variability.

Methods: A method is proposed to find outliers with respect to the individual regression line, followed by a step to find regression lines with excessive variability and finally a step to find regression lines with high bias.

Results: The model was applied to the results obtained by 52 laboratories for CD4%. From the 1340 data points, 35 were determined to be regression outliers. The second step revealed one regression line with excessive variability; the third step detected three regression lines with exceeding bias.

Conclusions: The methodology allows assessment of the long-term performance of laboratories, taking into account samples with different target values. Outliers in the first step indicate accidental mistakes, outliers in the second and third step point to high analytical variability or bias.

Clin Chem Lab Med 2010;48:645–50.


Corresponding author: Wim Coucke, Department of Clinical Biology, Scientific Institute of Public Health, J. Wytsmanstraat 14, 1050 Brussels, Belgium Phone: +32 2 642 55 23, Fax: +32 2 642 56 45,

Received: 2009-11-17
Accepted: 2010-1-4
Published Online: 2010-02-17
Published in Print: 2010-05-01

©2010 by Walter de Gruyter Berlin New York

Articles in the same Issue

  1. Editorials
  2. Laboratory medicine and natural disasters: are we ready for the challenge?
  3. Reference values: still a critical issue in laboratory medicine
  4. Review
  5. Contemporary platelet function testing
  6. Minireviews
  7. Disasters: where they find us
  8. Inter-laboratory variation in cerebrospinal fluid biomarkers for Alzheimer's disease: united we stand, divided we fall
  9. Opinion Paper
  10. Glycated hemoglobin (HbA1c): old dogmas, a new perspective?
  11. Guidelines and Recommendations
  12. IFCC reference procedures for measurement of the catalytic concentrations of enzymes: corrigendum, notes and useful advice
  13. Recommendations for the implementation of international standardization of glycated hemoglobin in Italy
  14. Genetics and Molecular Diagnostics
  15. UGT2B17 and SULT1A1 gene copy number variation (CNV) detection by LabChip microfluidic technology
  16. Genetic polymorphisms of CYP1A2, CYP3A4, CYP3A5, pregnane/steroid X receptor and constitutive androstane receptor in 207 healthy Spanish volunteers
  17. Automated genomic DNA extraction from saliva using the QIAxtractor
  18. General Clinical Chemistry and Laboratory Medicine
  19. A new statistical method for evaluating long-term analytical performance of laboratories applied to an external quality assessment scheme for flow cytometry
  20. Evaluation of the Becton-Dickinson rapid serum tube: does it provide a suitable alternative to lithium heparin plasma tubes?
  21. Immunoglobulin M antibodies to aquaporin-4 in neuromyelitis optica and related disorders
  22. Evaluation of the new body fluid mode on the Sysmex XE-5000 for counting leukocytes and erythrocytes in cerebrospinal fluid and other body fluids
  23. Extracellular haemoglobin, oxidative stress and quality of red blood cells relative to perioperative blood salvage
  24. Positive predictive value of serological diagnostic measures in celiac disease
  25. Retinol potentiates the inhibitory effect of ascorbic acid on uric acid assay
  26. Reference Values and Biological Variations
  27. Reference intervals for brain natriuretic peptide in healthy newborns and infants measured with an automated immunoassay platform
  28. Factors influencing serum total tryptase concentrations in a general adult population
  29. Leptin and adiponectin levels in pubertal children: relationship with anthropometric variables and body composition
  30. Cardiovascular risk factors and γ-glutamyltransferase fractions in healthy individuals
  31. Cancer Diagnostics
  32. Combined analysis of survivin autoantibody and carcinoembryonic antigen biomarkers for improved detection of colorectal cancer
  33. Oligoclonal bands and immunoglobulin isotype switch during monitoring of patients with multiple myeloma and autologous hematopoietic cell transplantation: a 16-year experience
  34. Letters to the Editor
  35. Methodological weakness in using correlation coefficients for assessing the interchangeability of analyte data between samples collected under different sampling conditions – the example of matrix metalloproteinase 9 determined in serum and plasma samples
  36. Intralipid causes falsely increased glucose concentrations with the Hemocue glucose analyzer
  37. Serum cholesterol: required and actual bias values
  38. Abstracts
  39. ISMD2010 Eighth International Symposium on Molecular Diagnostics
Downloaded on 6.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2010.122/html
Scroll to top button