Considerations for the development of a reference method for sequencing of haploid DNA – an opinion paper on behalf of the IFCC Committee on Molecular Diagnostics. International Federation of Clinical Chemistry and Laboratory Medicine
-
François Rousseau
, David Gancberg , Heinz Schimmel , Michael Neumaier , Alexandre Bureau , Cyril Mamotte , Ron van Schaik , Deborah Payne , Mario Pazzagli and Ian Young
Abstract
Following the completion of sequencing of the human genome, there has been a very rapid increase in the development of new molecular diagnostic tests. However, the numerous genetic tests and genetic testing technologies offered do not always satisfy essential quality criteria required to ensure confidence in the results that are produced. This is of particular importance for genetic tests since many patients may be tested for a particular genetic defect only once in their lifetime. Thus, there is a pressing need for comprehensive guidelines for the validation of molecular diagnostic tests and procedures, including DNA sequencing, the latter being a fundamental aspect of the development and validation of most genetic tests. To that end, the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Committee for Molecular Diagnostics has prepared the following paper that describes a possible approach to the development of a reference method for sequencing of haploid DNA. We discuss various aspects which should be considered before, during and after applying the sequencing procedure, in order to achieve results with a known level of confidence, including robustness and assessments of quality.
Clin Chem Lab Med 2009;47:1343–50.
©2009 by Walter de Gruyter Berlin New York
Articles in the same Issue
- Editorial
- The journal impact factor: navigating between Scylla and Charybdis
- Opinion Papers
- Journal Impact Factor: it will go away soon
- The Journal Impact Factor: don't expect its demise any time soon
- Reviews
- Discordant total and free prostate-specific antigen (PSA) assays: does calibration with WHO reference materials diminish the problem?
- Molecular diagnostics in acute leukemias
- Opinion Paper
- Considerations for the development of a reference method for sequencing of haploid DNA – an opinion paper on behalf of the IFCC Committee on Molecular Diagnostics. International Federation of Clinical Chemistry and Laboratory Medicine
- General Clinical Chemistry and Laboratory Medicine
- Meta-analyses of diagnostic studies
- Development and implementation of an automatic system for verification, validation and delivery of laboratory test results
- Comparison of visual vs. automated detection of lipemic, icteric and hemolyzed specimens: can we rely on a human eye?
- Prevalence of thyroid autoimmunity and subclinical hypothyroidism in persons with chronic kidney disease not requiring chronic dialysis
- Serum albumin fragmentation in end-stage renal disease patients – a pilot study
- Enhanced bone metabolism in vegetarians – the role of vitamin B12 deficiency
- Impaired anti-inflammatory function of apolipoprotein A-II concentrations predicts metabolic syndrome and diabetes at 4 years follow-up in elderly Turks
- Detection of myelin autoantibodies: evaluation of an assay system for diagnosis of multiple sclerosis in differentiation from other central nervous system diseases
- The rate of manual peripheral blood smear reviews in outpatients
- Markers of infection in inpatients and outpatients with acute Q-fever
- Validation and Outcome Studies
- Potential utility of the new Sysmex XE 5000 red blood cell extended parameters in the study of disorders of iron metabolism
- A new turbidimetric method for assaying serum C-reactive protein based on phosphocholine interaction
- Potential of the Sebia Capillarys® neonat fast automated system for neonatal screening of sickle cell disease
- Biochemical role of intravaginal sildenafil citrate as a novel antiabortive agent in unexplained recurrent spontaneous miscarriage: first clinical study of four case reports from Egypt
- Cancer Diagnostics
- Hypoxia related growth factors and p53 in preoperative sera from patients with colorectal cancer – evaluation of the prognostic significance of these agents
- Letters to the Editor
- Quick and easy colorimetric test for calibration control of liquid handling workstations
- GSTP1*B allele increases the risk for asthma in children
Articles in the same Issue
- Editorial
- The journal impact factor: navigating between Scylla and Charybdis
- Opinion Papers
- Journal Impact Factor: it will go away soon
- The Journal Impact Factor: don't expect its demise any time soon
- Reviews
- Discordant total and free prostate-specific antigen (PSA) assays: does calibration with WHO reference materials diminish the problem?
- Molecular diagnostics in acute leukemias
- Opinion Paper
- Considerations for the development of a reference method for sequencing of haploid DNA – an opinion paper on behalf of the IFCC Committee on Molecular Diagnostics. International Federation of Clinical Chemistry and Laboratory Medicine
- General Clinical Chemistry and Laboratory Medicine
- Meta-analyses of diagnostic studies
- Development and implementation of an automatic system for verification, validation and delivery of laboratory test results
- Comparison of visual vs. automated detection of lipemic, icteric and hemolyzed specimens: can we rely on a human eye?
- Prevalence of thyroid autoimmunity and subclinical hypothyroidism in persons with chronic kidney disease not requiring chronic dialysis
- Serum albumin fragmentation in end-stage renal disease patients – a pilot study
- Enhanced bone metabolism in vegetarians – the role of vitamin B12 deficiency
- Impaired anti-inflammatory function of apolipoprotein A-II concentrations predicts metabolic syndrome and diabetes at 4 years follow-up in elderly Turks
- Detection of myelin autoantibodies: evaluation of an assay system for diagnosis of multiple sclerosis in differentiation from other central nervous system diseases
- The rate of manual peripheral blood smear reviews in outpatients
- Markers of infection in inpatients and outpatients with acute Q-fever
- Validation and Outcome Studies
- Potential utility of the new Sysmex XE 5000 red blood cell extended parameters in the study of disorders of iron metabolism
- A new turbidimetric method for assaying serum C-reactive protein based on phosphocholine interaction
- Potential of the Sebia Capillarys® neonat fast automated system for neonatal screening of sickle cell disease
- Biochemical role of intravaginal sildenafil citrate as a novel antiabortive agent in unexplained recurrent spontaneous miscarriage: first clinical study of four case reports from Egypt
- Cancer Diagnostics
- Hypoxia related growth factors and p53 in preoperative sera from patients with colorectal cancer – evaluation of the prognostic significance of these agents
- Letters to the Editor
- Quick and easy colorimetric test for calibration control of liquid handling workstations
- GSTP1*B allele increases the risk for asthma in children