Home Error tracking in a clinical biochemistry laboratory
Article
Licensed
Unlicensed Requires Authentication

Error tracking in a clinical biochemistry laboratory

  • Pal Bela Szecsi and Lars Ødum
Published/Copyright: August 7, 2009

Abstract

Background: We report our results for the systematic recording of all errors in a standard clinical laboratory over a 1-year period.

Methods: Recording was performed using a commercial database program. All individuals in the laboratory were allowed to report errors. The testing processes were classified according to function, and errors were classified as pre-analytical, analytical, post-analytical, or service-related, and then further divided into descriptive subgroups. Samples were taken from hospital wards (38.6%), outpatient clinics (25.7%), general practitioners (29.4%), and other hospitals.

Results: A total of 1189 errors were reported in 1151 reports during the first year, corresponding to an error rate of 1 error for every 142 patients, or 1 per 1223 tests. The majority of events were due to human errors (82.6%), and only a few (4.3%) were the result of technical errors. Most of the errors (81%) were pre-analytical. Of the remainder, 10% were analytical, 8% were post-analytical, and 1% was service-related. Nearly half of the errors (n=550) occurred with samples received from general practitioners or clinical hospital wards. Identification errors were relatively common when non-technicians collected blood samples.

Conclusions: Each clinical laboratory should record errors in a structured manner. A relation database is a useful tool for the recording and extraction of data, as the database can be structured to reflect the workflow at each individual laboratory.

Clin Chem Lab Med 2009;47:1253–7.


Corresponding author: Pal B. Szecsi, Department of Clinical Biochemistry, University of Copenhagen, Gentofte Hospital, Niels Andersens Vej 65, 2900 Hellerup, Denmark Phone: +45 3977 7494, Fax: +45 3977 7616,

Received: 2009-4-13
Accepted: 2009-6-28
Published Online: 2009-08-07
Published in Print: 2009-10-01

©2009 by Walter de Gruyter Berlin New York

Articles in the same Issue

  1. Editorial
  2. Cardiac troponins: what we knew, what we know – where are we now?
  3. Review
  4. Measurement of circulating concentrations of cardiac troponin I and T in healthy subjects: a tool for monitoring myocardial tissue renewal?
  5. Opinion Papers
  6. A critical appraisal of experimental factors influencing the definition of the 99th percentile limit for cardiac troponins
  7. Genetic and biochemical heterogeneity of cardiac troponins: clinical and laboratory implications
  8. The future of hospital laboratories. Position statement from the Royal Belgian Society of Clinical Chemistry (RBSCC)
  9. Point
  10. Quantity quotient reporting. A proposal for a standardized presentation of laboratory results
  11. Counterpoint
  12. Quantity quotient reporting. Counterpoint
  13. Perspectives
  14. Increasing laboratory medicine activities in China: research and publications
  15. Contributions in Biochemistry and Molecular Biology from China and other top-ranking countries: a 10-year survey of the literature
  16. Genetics and Molecular Diagnostics
  17. SOCS3 and IRS-1 gene expression differs between genotype 1 and genotype 2 hepatitis C virus-infected HepG2 cells
  18. Polymorphisms of the β1-adrenergic receptor gene are associated with essential hypertension in Chinese
  19. Egyptian glycogen storage disease type III – identification of six novel AGL mutations, including a large 1.5 kb deletion and a missense mutation p.L620P with subtype IIId
  20. Novel rare alleles of ABCA1 are exclusively associated with extreme high-density lipoprotein-cholesterol levels among the Han Chinese
  21. –308G>A and –1031T>C tumor necrosis factor gene polymorphisms in Tunisian patients with coronary artery disease
  22. General Clinical Chemistry and Laboratory Medicine
  23. Error tracking in a clinical biochemistry laboratory
  24. HbA1c measurements from dried blood spots: validation and patient satisfaction
  25. Pre-transplant serum concentrations of anti-endothelial cell antibody in panel reactive antibody negative renal recipients and its impact on acute rejection
  26. Cancer Diagnostics
  27. Detection of Meningeosis neoplastica by real-time quantitation of telomerase activity
  28. The prognostic utility of haptoglobin genotypes in squamous cell carcinoma of the head and neck
  29. Evaluation of a new method for the diagnosis of alterations of Lens culinaris agglutinin binding of thyroglobulin molecules in thyroid carcinoma
  30. The soluble transferrin receptor (TfR)-F-Index is not applicable as a test for iron status in patients with chronic lymphocytic leukemia
  31. Impact of calibration fitting models on the clinical value of chromogranin A
  32. Letters to the Editor
  33. Clinical value of a competitive NT-proBNP enzyme immunoassay compared to the Roche NT-proBNP platform
  34. Should gender-related reference values be used for total bilirubin?
  35. A novel nonsense mutation in the albumin gene (c.1275 C>A) causing analbuminemia in a Tunisian boy
  36. Abstracts
  37. 41st National Congress of the Italian Society of Clinical Biochemistry and Clinical Molecular Biology, 2nd Joint National Event SIBioC-SIMeL
Downloaded on 6.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2009.272/html?lang=en
Scroll to top button