Home Plasma procalcitonin measured by time-resolved amplified cryptate emission (TRACE) in liver transplant patients. A prognosis marker of early infectious and non-infectious postoperative complications
Article
Licensed
Unlicensed Requires Authentication

Plasma procalcitonin measured by time-resolved amplified cryptate emission (TRACE) in liver transplant patients. A prognosis marker of early infectious and non-infectious postoperative complications

  • Belén Prieto , Elena Llorente , Ignacio González-Pinto and Francisco V. Alvarez
Published/Copyright: March 14, 2008

Abstract

Background: Elevated procalcitonin (PCT) levels are observed after major surgery, such as orthotopic liver transplantation (OLTx). The aim of this observational study was to evaluate PCT kinetics during the first 5 following days after surgery to establish the prognostic value of PCT changes in the outcome of OLTx, and to predict medical, technical and infectious complications. PCT was also evaluated in the differential diagnosis of infection vs. rejection.

Methods: A total of 64 OLTx were performed in 58 patients; they were split into two groups: with and without complications. Out of these patients, 18 developed infection, and nine rejection. PCT was measured before and during surgery, 12 h after transplantation and daily for the 5 following days. PCT was also measured the day when infection or rejection was diagnosed, and on the previous day. PCT was determined by time-resolved amplified cryptate emission (TRACE) technology.

Results: PCT elevation began at 12 h after surgery, reaching a peak on the 1st day in both groups. Significantly higher PCT concentrations were found in the group of patients developing complications, on the 5 postoperative days. It was found that a 24 h PCT value higher than 1.92 μg/L increased by 9.1-time-fold the risk of complications. When infection was diagnosed, a second peak of PCT was observed, but no PCT elevation was shown in rejection.

Conclusions: Daily monitored PCT provides valuable information about the early outcome of OLTx.

Clin Chem Lab Med 2008;46:660–6.


Corresponding author: Belén Prieto García, PhD, Hospital Universitario Central de Asturias, c/Celestino Villamil, s/n – 33006 Oviedo, Spain Phone/Fax: +34-985-108073,

Received: 2007-10-3
Accepted: 2008-1-18
Published Online: 2008-03-14
Published in Print: 2008-05-01

©2008 by Walter de Gruyter Berlin New York

Articles in the same Issue

  1. Editorial
  2. Comparability of tumor marker immunoassays: still an important issue for clinical diagnostics?
  3. Review
  4. The diagnostic role of autoantibodies in the prediction of organ-specific autoimmune diseases
  5. Validation and Outcome Studies
  6. Alternative antibody for the detection of CA125 antigen: a European multicenter study for the evaluation of the analytical and clinical performance of the Access® OV Monitor assay on the UniCel® DxI 800 Immunoassay System
  7. Alternative antibody for the detection of CA19-9 antigen: a European multicenter study for the evaluation of the analytical and clinical performance of the Access® GI Monitor assay on the UniCel® DxI 800 Immunoassay System
  8. Alternative antibody for the detection of CA15-3 antigen: a European multicenter study for the evaluation of the analytical and clinical performance of the Access® BR Monitor assay on the UniCel® DxI 800 Immunoassay System
  9. Toward metrological traceability in the determination of prostate-specific antigen (PSA): calibrating Beckman Coulter Hybritech Access PSA assays to WHO standards compared with the traditional Hybritech standards
  10. Multicentre evaluation of a new point-of-care test for the determination of CK-MB in whole blood
  11. Down's syndrome screening: population statistic dependency of screening performance
  12. General Clinical Chemistry and Laboratory Medicine
  13. Association between plasma thiols and immune activation marker neopterin in stable coronary heart disease
  14. Role for mitochondrial uncoupling protein-2 (UCP2) in hyperhomocysteinemia and venous thrombosis risk?
  15. Plasma procalcitonin measured by time-resolved amplified cryptate emission (TRACE) in liver transplant patients. A prognosis marker of early infectious and non-infectious postoperative complications
  16. Interactions of lipoprotein(a) with diabetes mellitus, apolipoprotein B and cholesterol enhance the prognostic values for coronary artery disease
  17. Association of thyroid stimulating hormone and coronary lipid risk factors with lipid peroxidation in hypothyroidism
  18. The effect of the mode of delivery on the maternal-neonatal carnitine blood levels and antioxidant status
  19. Time to reconsider the clinical value of immunoglobulin G4 to foods?
  20. Reference Values
  21. Determination of reference intervals for 26 commonly measured biochemical analytes with consideration of long-term within-individual variation
  22. Beverage-specific effects of ethanol consumption on its biological markers
  23. Limits of preservation of samples for urine strip tests and particle counting
  24. Reference ranges and diagnostic thresholds of laboratory markers of cardiac damage and dysfunction in a population of apparently healthy black Africans
  25. Letters to the Editor
  26. External quality assessment schemes for real-time PCR: a statistical procedure to corrective actions
  27. Application of two different microarray-based copy-number detection methodologies – array-comparative genomic hybridization and array-multiplex amplifiable probe hybridization – with identical amplifiable target sequences
  28. Criticism to the article: “Toward standardization of carbohydrate-deficient transferrin (CDT) measurements: I. Analyte definition and proposal of a candidate reference method.” Authors: J.O. Jeppsson et al. Clin Chem Lab Med 2007;45(4):558–562
  29. Standardization of carbohydrate-deficient transferrin: reply to the letter by Tagliaro and Bortolotti
  30. Comment on: Bellini C, Serra G, Risso D, Mazzella M, Bonioli E. Reliability assessment of glucose measurement by HemoCue analyser in a neonatal intensive care unit. Clin Chem Lab Med 2007;45(11):1549–54
  31. Reliability assessment of glucose measurement by HemoCue analyzer in a neonatal intensive care unit: reply to Dr. Joakim Hagvik
Downloaded on 15.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2008.123/html
Scroll to top button