The exponentially weighted moving average (EWMA) rule compared with traditionally used quality control rules
-
Kristian Linnet
Abstract
Background: The exponentially moving average (EWMA) rule for internal quality control is a well-known type of control rule in industry. Here, the power of the EWMA rule is evaluated to outline the potential of this type of control rule in clinical chemistry.
Methods: Using simulations, the power of the EWMA rule was explicitly compared with that of commonly used rules in clinical chemistry. The type I error levels were standardized to common values to achieve unbiased comparisons.
Results: For small to moderately large errors (systematic errors up to 2–3 standard deviations), the EWMA rule outperforms simple rules (N=1) and multi-rules (N=2–6). For example, for a systematic error of 2s, the EWMA rule equivalent to the 13s rule has a power of 0.30, whereas the 13s rule only displays a power of approximately 0.15. For N=4, comparison was carried out with the 13s/22s/R4s/41s rule. Here the common type I error level is 0.017. At all error levels, the EWMA rule is superior to the multi-rule. For example, given a 1s systematic error, the EWMA rule has a power (0.4) of twice the value of the multi-rule (0.2).
Conclusion: The EWMA rule is an efficient control rule with regard to systematic errors that should be considered for general application in the field of clinical chemistry.
References
1. Roberts SW. Control chart tests based on geometric moving averages. Technometrics 1959; 1:239–50.10.1080/00401706.1959.10489860Suche in Google Scholar
2. Crowder SV. Design of exponentially weighted moving average schemes. J Qual Technol 1989; 21:155–62.10.1080/00224065.1989.11979164Suche in Google Scholar
3. Cembrowski GS, Westgard JO, Eggert AA, Toren EC Jr. Trend detection in control data: optimization and interpretation of Trigg's technique for trend analysis. Clin Chem 1975; 21:1396–405.10.1093/clinchem/21.10.1396Suche in Google Scholar
4. Neubauer AS. The EWMA control chart: properties and comparison with other quality-control procedures by computer simulation. Clin Chem 1997; 43:594–601.10.1093/clinchem/43.4.594Suche in Google Scholar
5. Jansen RT, Laeven M, Kardol W. Internal quality control system for non-stationary, non-ergodic analytical processes based upon exponentially weighted estimation of process means and process standard deviation. Clin Chem Lab Med 2002; 40:616–24.10.1515/CCLM.2002.107Suche in Google Scholar PubMed
6. Westgard JO. Internal quality control: planning and implementation strategies. Ann Clin Biochem 2003; 40:593–611.10.1258/000456303770367199Suche in Google Scholar PubMed
7. Linnet K. Mean and variance rules are more powerful or selective than quality control rules based on individual values. Eur J Clin Chem Clin Biochem 1991; 29:417–24.10.1515/cclm.1991.29.7.417Suche in Google Scholar PubMed
8. Winkel P, Zhang NF. Serial correlation of quality control data – on the use of proper control charts. Scand J Clin Lab Invest 2004; 64:195–204.10.1080/00365510410005442Suche in Google Scholar PubMed
9. Marquis P. [A new software for quality control at a laboratory]. Ann Biol Clin (Paris) 2000; 58:233–6.Suche in Google Scholar
©2006 by Walter de Gruyter Berlin New York
Artikel in diesem Heft
- Natriuretic peptides and evidence-based quality specifications
- Preanalytical variability: the dark side of the moon in laboratory testing
- Clinical relevance of biological variation: the lesson of brain natriuretic peptide (BNP) and NT-proBNP assay
- Hepatorenal syndrome
- Modified Levey-Jennings charts for calculated laboratory tests
- Increased free malondialdehyde concentrations in smokers normalise with a mixed fruit and vegetable juice concentrate: a pilot study
- The exponentially weighted moving average (EWMA) rule compared with traditionally used quality control rules
- Intermethod calibration of alanine aminotransferase (ALT) and γ-glutamyltransferase (GGT) results: application to Fibrotest® and Actitest® scores
- Comparison of TEST 1 with SRS 100 and ICSH reference method for the measurement of the length of sedimentation reaction in blood
- Multicenter evaluation of the interference of hemoglobin, bilirubin and lipids on Synchron LX-20 assays
- Technical evaluation of the Beckman Coulter OV-Monitor (CA 125 antigen) immunoassay
- Erythrocyte membrane Na+,K+-ATPase and Mg2+-ATPase activities in subjects with methylenetetrahydrofolate reductase (MTHFR) 677 C→T genotype and moderate hyperhomocysteinaemia. The role of L-phenylalanine and L-alanine
- Matrix metalloproteinases and their inhibitors in different acute stroke subtypes
- Pyrosequencing protocol requiring a unique biotinylated primer
- Detection of antibodies against 60-, 65- and 70-kDa heat shock proteins in paediatric patients with various disorders using Western blotting and ELISA
- Quantitative determination of erythrocyte folate vitamer distribution by liquid chromatography-tandem mass spectrometry
- Time-level relationship between indicators of oxidative stress and Glasgow Coma Scale scores of severe head injury patients
- Stepwise strategies in analysing haematuria and leukocyturia in screening
- Elevation of serum cerebral injury markers correlates with serum choline decline after coronary artery bypass grafting surgery
- Drug screening in urine by cloned enzyme donor immunoassay (CEDIA) and kinetic interaction of microparticles in solution (KIMS): a comparative study
- Release of anandamide from blood cells
- Rapid decrease in plasma D-lactate as an early potential predictor of diminished 28-day mortality in critically ill septic shock patients
- Evaluation of an immunoassay of whole blood sirolimus in pediatric transplant patients in comparison with high-performance liquid chromatography/tandem mass spectrometry
- Sample processing and its preanalytical impact on the measurement of circulating matrix metalloproteinases
- Physiological matrix metalloproteinase (MMP) concentrations: comparison of serum and plasma specimens
- Importance of the functional sensitivity determination of a serum hyaluronic acid assay for the prediction of liver fibrosis in patients with features of the metabolic syndrome
- The dilemma of invasive and non-invasive investigations for adult and paediatric non-alcoholic fatty liver disease: has the time come for a new biochemical marker?
- Is cystatin C a reliable renal marker in trauma?
- On the independence of intraindividual reference values
- Sixth International Symposium on Molecular Diagnostics, Graz, Austria, May 25-27, 2006
Artikel in diesem Heft
- Natriuretic peptides and evidence-based quality specifications
- Preanalytical variability: the dark side of the moon in laboratory testing
- Clinical relevance of biological variation: the lesson of brain natriuretic peptide (BNP) and NT-proBNP assay
- Hepatorenal syndrome
- Modified Levey-Jennings charts for calculated laboratory tests
- Increased free malondialdehyde concentrations in smokers normalise with a mixed fruit and vegetable juice concentrate: a pilot study
- The exponentially weighted moving average (EWMA) rule compared with traditionally used quality control rules
- Intermethod calibration of alanine aminotransferase (ALT) and γ-glutamyltransferase (GGT) results: application to Fibrotest® and Actitest® scores
- Comparison of TEST 1 with SRS 100 and ICSH reference method for the measurement of the length of sedimentation reaction in blood
- Multicenter evaluation of the interference of hemoglobin, bilirubin and lipids on Synchron LX-20 assays
- Technical evaluation of the Beckman Coulter OV-Monitor (CA 125 antigen) immunoassay
- Erythrocyte membrane Na+,K+-ATPase and Mg2+-ATPase activities in subjects with methylenetetrahydrofolate reductase (MTHFR) 677 C→T genotype and moderate hyperhomocysteinaemia. The role of L-phenylalanine and L-alanine
- Matrix metalloproteinases and their inhibitors in different acute stroke subtypes
- Pyrosequencing protocol requiring a unique biotinylated primer
- Detection of antibodies against 60-, 65- and 70-kDa heat shock proteins in paediatric patients with various disorders using Western blotting and ELISA
- Quantitative determination of erythrocyte folate vitamer distribution by liquid chromatography-tandem mass spectrometry
- Time-level relationship between indicators of oxidative stress and Glasgow Coma Scale scores of severe head injury patients
- Stepwise strategies in analysing haematuria and leukocyturia in screening
- Elevation of serum cerebral injury markers correlates with serum choline decline after coronary artery bypass grafting surgery
- Drug screening in urine by cloned enzyme donor immunoassay (CEDIA) and kinetic interaction of microparticles in solution (KIMS): a comparative study
- Release of anandamide from blood cells
- Rapid decrease in plasma D-lactate as an early potential predictor of diminished 28-day mortality in critically ill septic shock patients
- Evaluation of an immunoassay of whole blood sirolimus in pediatric transplant patients in comparison with high-performance liquid chromatography/tandem mass spectrometry
- Sample processing and its preanalytical impact on the measurement of circulating matrix metalloproteinases
- Physiological matrix metalloproteinase (MMP) concentrations: comparison of serum and plasma specimens
- Importance of the functional sensitivity determination of a serum hyaluronic acid assay for the prediction of liver fibrosis in patients with features of the metabolic syndrome
- The dilemma of invasive and non-invasive investigations for adult and paediatric non-alcoholic fatty liver disease: has the time come for a new biochemical marker?
- Is cystatin C a reliable renal marker in trauma?
- On the independence of intraindividual reference values
- Sixth International Symposium on Molecular Diagnostics, Graz, Austria, May 25-27, 2006