Home Separation of Serum Proteins by Automated Capillary Zone Electrophoresis
Article
Licensed
Unlicensed Requires Authentication

Separation of Serum Proteins by Automated Capillary Zone Electrophoresis

  • Xavier Bossuyt
Published/Copyright: June 1, 2005
Become an author with De Gruyter Brill
Clinical Chemistry and Laboratory Medicine (CCLM)
From the journal Volume 41 Issue 6

Abstract

Capillary zone electrophoresis (CZE) of serum proteins is increasingly gaining impact in clinical laboratories. Two automated multichannel instruments dedicated to the separation of serum proteins have become available over the last 6 years, the Paragon CZE 2000® (Beckman Coulter, CA, USA) and, more recently, the Capillarys® (Sebia, France). This review focuses on the performance of these commercial instruments to separate serum proteins in a clinical laboratory setting. The utility of CZE to recognize various dysproteinemias and to detect and identify monoclonal proteins will be described and systematically reviewed. The reader will be provided with a summation and an understanding of CZE-specific interference.

:
Published Online: 2005-06-01
Published in Print: 2003-06-17

Copyright © 2003 by Walter de Gruyter GmbH & Co. KG

Articles in the same Issue

  1. Editorial
  2. Biomedical Applications of Capillary Electrophoresis
  3. Capillary Electrophoresis – A High Performance Analytical Separation Technique
  4. The Analysis of Carbohydrate-Deficient Transferrin, Marker of Chronic Alcoholism, Using Capillary Electrophoresis
  5. Capillary Electrophoresis of Hemoglobin
  6. Capillary Electrophoresis for the Determination of Organic Acidurias in Body Fluids: A Review
  7. Separation of Serum Proteins by Automated Capillary Zone Electrophoresis
  8. Is Capillary Electrophoresis a Method of Choice for Systematic Toxicological Analysis?
  9. Capillary Zone Electrophoresis of Serum Proteins: Effects of Changed Analytical Conditions
  10. Type-Specific Detection of Human Papillomaviruses in a Routine Laboratory Setting – Improved Sensitivity and Specificity of PCR and Sequence Analysis Compared to Direct Hybridisation
  11. Identification of Lipoproteins of Intestinal Origin in Human Atherosclerotic Plaque
  12. Molecular Cloning, Sequencing and Functional Expression of Porcine Thyrotropin (TSH) Receptor cDNA
  13. Are Results of Fibrinogen Measurements Transferable?
  14. Comparison of Several Point-of-Care Testing (POCT) Glucometers with an Established Laboratory Procedure for the Diagnosis of Type 2 Diabetes Using the Discordance Rate. A New Statistical Approach
  15. Association between Increased Serum Cholesterol and Signs of Depressive Mood
  16. Report from the Second European Symposium on Clinical Laboratory and in vitro Diagnostic Industry. Physiological Reference Values: A Shared Business? Barcelona, 67 February 2003
  17. Meetings and Awards
Downloaded on 12.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2003.116/html?lang=en
Scroll to top button