Comparison of Several Point-of-Care Testing (POCT) Glucometers with an Established Laboratory Procedure for the Diagnosis of Type 2 Diabetes Using the Discordance Rate. A New Statistical Approach

  • Isabel Püntmann , Werner Wosniok and Rainer Haeckel
Published/Copyright: June 1, 2005
Become an author with De Gruyter Brill
Clinical Chemistry and Laboratory Medicine (CCLM)
From the journal Volume 41 Issue 6

Abstract

The applicability of point-of-care testing (POCT) glucometers for monitoring blood glucose concentrations has been demonstrated. However, their use in diagnosing type 2 diabetes is still debated. Therefore, a new statistical procedure for estimating discordance rates (DRs) was applied in comparing a well-established laboratory method (Ebio) with another laboratory method Cobas Integra 700) and with several POCT glucometers (Accu-Chek, Accutrend, Elite, HemoCue, Omni) in detecting glucose intolerance states. All procedures led to parallel glucose concentration patterns in capillary blood, venous plasma, and venous blood during oral glucose tolerance tests. However, the mean concentrations differed more or less. The Ebio and Integra results agreed within a maximal deviation of 3%. In blood samples, the HemoCue and Accutrend results were closest to the laboratory procedures (Ebio and Integra) and the highest differences were obtained with the Elite. Comparing whole blood values with those obtained in the aqueous blood compartment (Omni), even greater differences were observed. When all procedures were referred to the same glucose standard, the Ebio, Integra, Accutrend, and Omni results remained almost unchanged, whereas the Elite "moved" toward the Ebio results, and the Accu-Chek results toward the Omni results. Thus, traceability to an aqueous standard was observed with the Ebio, Integra, Accutrend, and Elite in all three sample systems. The Accu-Chek was only traceable in the presence of albumin, and HemoCue was not traceable at all.

The clinical relevance of the differences observed between Ebio and POCT glucometers was tested by comparing the relative number of discordant classifications. The highest DRs were observed in the fasting state. They were higher in capillary blood than in the other sample systems. The DRs were found higher with POCT glucometers than with the other established laboratory procedure (Integra). Thus, at least in the fasting state, all POCT glucometers were less reliable than the established laboratory procedures and above the chosen criteria of clinical acceptability (DR≤5%). After transforming all glucometer results with a regression function (bias correction), the DRs were less than 5% if compared with the Ebio procedure in all sample systems.

In conclusion, the WHO recommendation not to use POCT glucometers for diagnosing type 2 diabetes must be supported. However, after proper recalibration, the tested systems were acceptable. Therefore, manufacturers should reconsider their calibration procedure. Those POCT procedures should be preferred that can be referred to aqueous glucose solutions.

:
Published Online: 2005-06-01
Published in Print: 2003-06-17

Copyright © 2003 by Walter de Gruyter GmbH & Co. KG

Articles in the same Issue

  1. Editorial
  2. Biomedical Applications of Capillary Electrophoresis
  3. Capillary Electrophoresis – A High Performance Analytical Separation Technique
  4. The Analysis of Carbohydrate-Deficient Transferrin, Marker of Chronic Alcoholism, Using Capillary Electrophoresis
  5. Capillary Electrophoresis of Hemoglobin
  6. Capillary Electrophoresis for the Determination of Organic Acidurias in Body Fluids: A Review
  7. Separation of Serum Proteins by Automated Capillary Zone Electrophoresis
  8. Is Capillary Electrophoresis a Method of Choice for Systematic Toxicological Analysis?
  9. Capillary Zone Electrophoresis of Serum Proteins: Effects of Changed Analytical Conditions
  10. Type-Specific Detection of Human Papillomaviruses in a Routine Laboratory Setting – Improved Sensitivity and Specificity of PCR and Sequence Analysis Compared to Direct Hybridisation
  11. Identification of Lipoproteins of Intestinal Origin in Human Atherosclerotic Plaque
  12. Molecular Cloning, Sequencing and Functional Expression of Porcine Thyrotropin (TSH) Receptor cDNA
  13. Are Results of Fibrinogen Measurements Transferable?
  14. Comparison of Several Point-of-Care Testing (POCT) Glucometers with an Established Laboratory Procedure for the Diagnosis of Type 2 Diabetes Using the Discordance Rate. A New Statistical Approach
  15. Association between Increased Serum Cholesterol and Signs of Depressive Mood
  16. Report from the Second European Symposium on Clinical Laboratory and in vitro Diagnostic Industry. Physiological Reference Values: A Shared Business? Barcelona, 67 February 2003
  17. Meetings and Awards
Downloaded on 11.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2003.123/html
Scroll to top button