Commutability of the CRM 470 C-Reactive Protein Value in the Dade Behring N High Sensitivity CRP Assay
-
A. Myron Johnson
, Thomas B. Ledue and Marilyn F. Collins
Abstract
Certified Reference Material 470 (CRM 470) demonstrates commutability with both the manufacturer's calibrator and with dilutions of serum pools in the Dade Behring N High Sensitivity assay for C-reactive protein (CRP). Both regression and back calibration show similar nonlinearity for all materials, largely due to the method of calibration curve fitting used in this assay. Significant differences in values among the currently available commercial assays can be largely overcome by using appropriate calibration curve fitting and the recommended value transfer protocol, which includes a minimum of two assay runs on each of at least 3 separate days, with weight correction of all reconstitutions and dilutions. An initial weight-corrected dilution should be made each day because of the relatively high level of CRP in CRM 470. In our opinion, the degree of nonlinearity, imprecision, and differences in values in currently available assays renders the use of fixed clinical decision cut-points questionable for high-sensitivity CRP. An alternative approach is suggested.
Copyright © 2003 by Walter de Gruyter GmbH & Co. KG
Articles in the same Issue
- Erythrocyte Sedimentation Rate: Innovative Techniques for an Obsolete Test?
- Liquid Chromatography-Tandem Mass Spectrometry – Application in the Clinical Laboratory
- New Sensitive Method for the Measurement of Lysozyme and Lactoferrin for the Assessment of Innate Mucosal Immunity. Part I: Time-Resolved Immunofluorometric Assay in Serum and Mucosal Secretions
- New Sensitive Method for the Measurement of Lysozyme and Lactoferrin to Explore Mucosal Innate Immunity. Part II: Time-Resolved Immunofluorometric Assay Used in HIV Patients with Oral Candidiasis
- Detection of Multiple Cytokines by Protein Arrays from Cell Lysate and Tissue Lysate
- Free Serum Cortisol during the Postoperative Acute Phase Response Determined by Equilibrium Dialysis Liquid Chromatography-Tandem Mass Spectrometry
- Analysis of the Dynamics of Cryoaggregation by Light-Scattering Spectrometry
- Biliary Bacteria in Living Related Liver Transplant Recipients: Microbiology and Rapid Detection System Using Flow Cytometry
- Rapid Determination of Brain Natriuretic Peptide in Patients with Acute Myocardial Infarction
- Preparation and Characterization of Reference Materials for Human Pancreatic Lipase: BCR 693 (from Human Pancreatic Juice) and BCR 694 (Recombinant)
- Commutability of the CRM 470 C-Reactive Protein Value in the Dade Behring N High Sensitivity CRP Assay
- Pilot External Quality Assessment Survey for Post-Market Vigilance of In Vitro Diagnostic Medical Devices and Investigation of Trueness of Participants' Results
- Fasting and Post-Glucose Load – Reference Limits for Peripheral Venous Plasma Glucose Concentration in Pregnant Women
- Glutathione Peroxidase Activity and Serum Selenium Concentration in Intrinsic Asthmatic Patients
- Increased Serum Soluble Transferrin Receptor Concentration Detects Subclinical Iron Deficiency in Healthy Adolescent Girls
- Serum Total Antioxidant Status, Erythrocyte Superoxide Dismutase and Whole-Blood Glutathione Peroxidase Activities in the Stanislas Cohort: Influencing Factors and Reference Intervals
- Plasma Thiols and Androgen Levels in Polycystic Ovary Syndrome
- Pretreatment of Serum Containing Hemoglobin Vesicles (Oxygen Carriers) to Prevent Their Interference in Laboratory Tests
- Length of Sedimentation Reaction in Blood: a Comparison of the Test 1 ESR System with the ICSH Reference Method and the Sedisystem 15
- The European Register for Specialists in Clinical Chemistry and Laboratory Medicine: Guide to the Register Version 2-2003 and Procedure for Re-registration
- Journées Internationales de Biologie – JIB 2002: A Booming European Show!
- Meetings and Awards
Articles in the same Issue
- Erythrocyte Sedimentation Rate: Innovative Techniques for an Obsolete Test?
- Liquid Chromatography-Tandem Mass Spectrometry – Application in the Clinical Laboratory
- New Sensitive Method for the Measurement of Lysozyme and Lactoferrin for the Assessment of Innate Mucosal Immunity. Part I: Time-Resolved Immunofluorometric Assay in Serum and Mucosal Secretions
- New Sensitive Method for the Measurement of Lysozyme and Lactoferrin to Explore Mucosal Innate Immunity. Part II: Time-Resolved Immunofluorometric Assay Used in HIV Patients with Oral Candidiasis
- Detection of Multiple Cytokines by Protein Arrays from Cell Lysate and Tissue Lysate
- Free Serum Cortisol during the Postoperative Acute Phase Response Determined by Equilibrium Dialysis Liquid Chromatography-Tandem Mass Spectrometry
- Analysis of the Dynamics of Cryoaggregation by Light-Scattering Spectrometry
- Biliary Bacteria in Living Related Liver Transplant Recipients: Microbiology and Rapid Detection System Using Flow Cytometry
- Rapid Determination of Brain Natriuretic Peptide in Patients with Acute Myocardial Infarction
- Preparation and Characterization of Reference Materials for Human Pancreatic Lipase: BCR 693 (from Human Pancreatic Juice) and BCR 694 (Recombinant)
- Commutability of the CRM 470 C-Reactive Protein Value in the Dade Behring N High Sensitivity CRP Assay
- Pilot External Quality Assessment Survey for Post-Market Vigilance of In Vitro Diagnostic Medical Devices and Investigation of Trueness of Participants' Results
- Fasting and Post-Glucose Load – Reference Limits for Peripheral Venous Plasma Glucose Concentration in Pregnant Women
- Glutathione Peroxidase Activity and Serum Selenium Concentration in Intrinsic Asthmatic Patients
- Increased Serum Soluble Transferrin Receptor Concentration Detects Subclinical Iron Deficiency in Healthy Adolescent Girls
- Serum Total Antioxidant Status, Erythrocyte Superoxide Dismutase and Whole-Blood Glutathione Peroxidase Activities in the Stanislas Cohort: Influencing Factors and Reference Intervals
- Plasma Thiols and Androgen Levels in Polycystic Ovary Syndrome
- Pretreatment of Serum Containing Hemoglobin Vesicles (Oxygen Carriers) to Prevent Their Interference in Laboratory Tests
- Length of Sedimentation Reaction in Blood: a Comparison of the Test 1 ESR System with the ICSH Reference Method and the Sedisystem 15
- The European Register for Specialists in Clinical Chemistry and Laboratory Medicine: Guide to the Register Version 2-2003 and Procedure for Re-registration
- Journées Internationales de Biologie – JIB 2002: A Booming European Show!
- Meetings and Awards