Home Fasting and Post-Glucose Load – Reference Limits for Peripheral Venous Plasma Glucose Concentration in Pregnant Women
Article
Licensed
Unlicensed Requires Authentication

Fasting and Post-Glucose Load – Reference Limits for Peripheral Venous Plasma Glucose Concentration in Pregnant Women

  • Lone G.M. Jørgensen , Tine Schytte , Ivan Brandslund , Marta Stahl , Per Hyltoft Petersen and Bent Andersen
Published/Copyright: June 1, 2005
Become an author with De Gruyter Brill
Clinical Chemistry and Laboratory Medicine (CCLM)
From the journal Volume 41 Issue 2

Abstract

Recently both the American Diabetes Organization (ADA) and World Health Organization (WHO) have revised the diagnostic recommendations for gestational diabetes mellitus (GDM), however, they did not not reach agreement on the criteria for diagnosis, the referral criteria for the confirmatory oral glucose tolerance test (OGTT), its standardization, and diagnostic cut-off point. The aims of this study were to investigate if the fasting venous plasma glucose mmol/l (f-vPG) and the 2-hour venous plasma glucose mmol/l (2h-vPG) after a WHO standardized 75 g oral glucose tolerance test (OGTT) in a non-risk group of pregnant women during first and third trimester of pregnancy deviated from that of risk groups, to establish a reference interval for f-vPG and 2h-vPG, and to investigate the predictive role of f-vPG for the 2h-vPG glucose concentration. This is a population-based case-control study where a consecutive number of pregnant women were invited to screening irrespective of their risk factors for GDM. All women filled in a questionnaire of the Danish national screening program on risk factors and had f-vPG and the 2h-vPG measured. By ruling out women with GDM and risk factors, we isolated a non-risk reference class. The ln f-vPG parametric 97.5 centile was less than 5% higher during week 32 of pregnancy than during week 20, and therefore these groups were combined. The f-vPG 95% reference interval was from 4.01 mmol/l (95% CI: 3.96 to 4.07 mmol/l) to 5.26 mmol/l (95% CI: 5.19 to 5.34 mmol/l). “The true upper normal limit”, the 99.9 centile, was 5.69 mmol/l (95% CI: 5.59 to 5.80 mmol/l). The f-vPG was 0.6 mmol/l lower over the whole range in pregnant women compared to age-matched non-pregnant women. The distribution of 2h-vPG concentrations at week 20 was non-Gaussian and therefore considered non-homogeneous, while it was Gaussian distributed and homogeneous at week 32. The 2h-vPG 95% reference interval of the combined weeks was from 2.80 mmol/l (95% CI: 2.56 to 3.04 mmol/l) to 7.58 mmol/l (95% CI: 7.34 to 7.82 mmol/l), and the upper limit of normal (99.9 centile) was 8.96 mmol/l (95% CI: 8.63 to 9.29 mmol/l). Distributions of f-vPG and 2h-vPG were distinct in our defined risk classes. In individual cases, no systematic correlation was found between the f-vPG concentration at week 20 and week 32. The f-vPG concentrations at any of the weeks did not predict the 2h-vPG level and no single clinical risk factor was decisive for the presence of GDM.

:
Published Online: 2005-06-01
Published in Print: 2003-02-21

Copyright © 2003 by Walter de Gruyter GmbH & Co. KG

Articles in the same Issue

  1. Erythrocyte Sedimentation Rate: Innovative Techniques for an Obsolete Test?
  2. Liquid Chromatography-Tandem Mass Spectrometry – Application in the Clinical Laboratory
  3. New Sensitive Method for the Measurement of Lysozyme and Lactoferrin for the Assessment of Innate Mucosal Immunity. Part I: Time-Resolved Immunofluorometric Assay in Serum and Mucosal Secretions
  4. New Sensitive Method for the Measurement of Lysozyme and Lactoferrin to Explore Mucosal Innate Immunity. Part II: Time-Resolved Immunofluorometric Assay Used in HIV Patients with Oral Candidiasis
  5. Detection of Multiple Cytokines by Protein Arrays from Cell Lysate and Tissue Lysate
  6. Free Serum Cortisol during the Postoperative Acute Phase Response Determined by Equilibrium Dialysis Liquid Chromatography-Tandem Mass Spectrometry
  7. Analysis of the Dynamics of Cryoaggregation by Light-Scattering Spectrometry
  8. Biliary Bacteria in Living Related Liver Transplant Recipients: Microbiology and Rapid Detection System Using Flow Cytometry
  9. Rapid Determination of Brain Natriuretic Peptide in Patients with Acute Myocardial Infarction
  10. Preparation and Characterization of Reference Materials for Human Pancreatic Lipase: BCR 693 (from Human Pancreatic Juice) and BCR 694 (Recombinant)
  11. Commutability of the CRM 470 C-Reactive Protein Value in the Dade Behring N High Sensitivity CRP Assay
  12. Pilot External Quality Assessment Survey for Post-Market Vigilance of In Vitro Diagnostic Medical Devices and Investigation of Trueness of Participants' Results
  13. Fasting and Post-Glucose Load – Reference Limits for Peripheral Venous Plasma Glucose Concentration in Pregnant Women
  14. Glutathione Peroxidase Activity and Serum Selenium Concentration in Intrinsic Asthmatic Patients
  15. Increased Serum Soluble Transferrin Receptor Concentration Detects Subclinical Iron Deficiency in Healthy Adolescent Girls
  16. Serum Total Antioxidant Status, Erythrocyte Superoxide Dismutase and Whole-Blood Glutathione Peroxidase Activities in the Stanislas Cohort: Influencing Factors and Reference Intervals
  17. Plasma Thiols and Androgen Levels in Polycystic Ovary Syndrome
  18. Pretreatment of Serum Containing Hemoglobin Vesicles (Oxygen Carriers) to Prevent Their Interference in Laboratory Tests
  19. Length of Sedimentation Reaction in Blood: a Comparison of the Test 1 ESR System with the ICSH Reference Method and the Sedisystem 15
  20. The European Register for Specialists in Clinical Chemistry and Laboratory Medicine: Guide to the Register Version 2-2003 and Procedure for Re-registration
  21. Journées Internationales de Biologie – JIB 2002: A Booming European Show!
  22. Meetings and Awards
Downloaded on 12.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.2003.031/html