External Quality Assessment in Clinical Chemistry: Review of the Situation in Croatia with Particular Reference to Equipment

  • Dubravka Juretić , Ivana Čepelak and Zlata Flegar-Meštrić
Published/Copyright: June 1, 2005
Become an author with De Gruyter Brill
Clinical Chemistry and Laboratory Medicine (CCLM)
From the journal Volume 37 Issue 6

Abstract

The effect of the use of new flame photometers (Ciba Corning 480, Chiron, Salzburg, Austria) and multichannel analyzers (BM Hitachi 904 or BM Hitachi 911, both Boehringer GmbH, Mannheim, Germany) on analytical quality was assessed in a number of medical biochemical laboratories (n=58) at health centers and general hospitals that provide primary health care services for the respective catchment areas.

The laboratories were supplied during 1996 and 1997 with new equipment, as part of the First Croatian Health Project, Primary Health Care Subproject, carried out by the Croatian Ministry of Health and Croatian Institute of Health Insurance.

We evaluated analytical performance of these laboratories for 19 analytes, according to the results reported in the Croatian External Quality Assessment Program for medical biochemical laboratories, performed four times per year.

Changes of percentages of particular methods used by the participating laboratories were observed for inorganic phosphate, total bilirubin, urea and creatinine. Such changes were even more pronounced for enzymes, where changes in the measurement procedure such as incubation temperature and buffers were observed in the methods used.

Evaluation of method performance revealed that after the introduction of new equipment interlaboratory variation decreased, so that an increasing proportion of laboratories included in the Project produced results within the target limits.

:
Published Online: 2005-06-01
Published in Print: 1999-06-01

Copyright © 1999 by Walter de Gruyter GmbH & Co. KG

Articles in the same Issue

  1. Meetings and Awards
  2. Are Cardiac Troponins the Myocardial Markers for the New Millenium?
  3. Leukocyte Activation Markers in Clinical Practice
  4. Hepatitis C Virus-Specific DNA Sequences in Human DNA: Differentiation by Means of Restriction Enzyme Analysis at the DNA Level of Healthy, Anti-HCV-Negative Individuals
  5. Characterization of Monoclonal Antibodies to Human Protein 1/Clara Cell 10 Kilodalton Protein
  6. Rapid Analysis of Parathion in Biological Samples Using Headspace Solid-Phase Micro-Extraction (HS-SPME) and Gas Chromatography/Mass Spectrometry (GC/MS)
  7. Semi-Automated Rapid Isoelectric Focusing of Apolipoproteins C from Human Plasma Using PhastSystem™ and Immunofixation
  8. The c-erbB-2 Oncogene Amplification by Competitive PCR in Aneuploid Cell Clones Flow Sorted from Breast Cancer Samples
  9. The Index of Individuality Is Often a Misinterpreted Quantity Characteristic
  10. Assessment of Package Inserts for Diagnostic Kits
  11. External Quality Assessment in Clinical Chemistry: Review of the Situation in Croatia with Particular Reference to Equipment
  12. Point-of-Care Testing: the Views of the Working Group of the Dutch Association of Clinical Chemistry
  13. Preliminary Evaluation of the New Hematology Analyzer COULTER® GEN•S™ in a University Hospital
  14. Use of Biochemical Markers in Acute Coronary Syndromes. IFCC Scientific Division, Committee on Standardization of Markers of Cardiac Damage
  15. Oxidative Stress in Skeletal Muscle. A.E. Rezuick, L. Packer, C.K. Sen. J.O. Hollosey and M.J. Jackson, editors
  16. Handbook of Lipoprotein Testing. N. Rifai, C.G. Warnick and M.H. Dominiczak, editors
  17. Erratum: Matthias Oberhoffer, Heinz Vogelsang, Stefan Rußwurm, Thomas Hartung and Konrad Reinhart. Outcome Prediction by Traditional and New Markers of Inflammation in Patients with Sepsis
Downloaded on 10.9.2025 from https://www.degruyterbrill.com/document/doi/10.1515/CCLM.1999.104/html
Scroll to top button