Multiple Regression Analysis of Interference Effects from a Hemoglobin-Based Oxygen Carrier Solution
-
Steven C. Kazmierczak
Abstract
The use of hemoglobin-based oxygen carrier solutions in patients requiring blood transfusion will necessitate that clinical laboratories have mechanisms in place to evaluate the potential interference effect of these substances on testing methods. Because these oxygen carrier solutions contain acellular hemoglobin, but do not contain many of the intracellular enzymes and ions present in erythrocytes, interference effects from blood substitutes may be quite different when compared to in vivo or in vitro lysis of erythrocytes. We evaluated the potential interference effect of Diaspirin Cross-linked Hemoglobin on 29 different clinical laboratory analytes. Various combinations of these analytes were tested using the Hitachi 747 and 911 systems, a Beckman CX3, an Abbott AxSym, a Bayer Immuno I, and a Dade ACA IV; a total of 60 analyte/instrument combinations. We used the method of multiple regression analysis to classify interferences as analyte-dependent, analyte-independent, or a combination of the first two types. The presence of clinically significant test interference was derived by using the criteria for maximum allowable error specified in the Clinical Laboratory Improvement Amendments of 1988. Using these criteria, we found significant interference from Diaspirin Cross-linked Hemoglobin with 13 of 29 analytes tested. Interference was noted with the Hitachi 747 and 911 methods for albumin, alkaline phosphatase, total and conjugated bilirubin, cholesterol, total carbon dioxide, iron, lactate dehydrogenase, magnesium, total protein, and triglyceride. In addition, Diaspirin Cross-linked Hemoglobin interfered with measurement of L-lactate using the ACA IV and minor interference was noted with glucose measured using the Beckman CX3. Data from the interference studies was graphically displayed in the form of interference plots. These plots show the maximum allowable test error, due to Diaspirin Cross-linked Hemoglobin, as a function of analyte and interferent concentrations. Evaluation of the potential interference effect of hemoglobin-based oxygen carrier solutions with use of multiple regression analysis and graphical display of the resultant data in the form of interference plots allows for more reliable reporting of test results from specimens containing these products.
Copyright (c)1999 by Walter de Gruyter GmbH & Co. KG
Articles in the same Issue
- Serum Amyloid A (SAA): a Concise Review of Biology, Assay Methods and Clinical Usefulness
- Serum Cystatin C as an Endogenous Marker of the Renal Function – a Review
- Improved Fluorescent PCR-Based Assay for Sizing CGG Repeats at the FRAXA Locus
- The Influence of Radiation and Chemotherapy-Related DNA Strand Breaks on Carcinogenesis: An Evaluation
- A Simple HPLC Method for Monitoring Mycophenolic Acid and Its Glucuronidated Metabolite in Transplant Recipients
- The Activities of Some Glycosaminoglycan-Degrading Enzymes in the Wall of the Umbilical Cord Artery and Their Alteration in Edema, Proteinuria, Hypertension (EPH)-Gestosis
- Endothelin-1- and Endothelin-Receptors in Lung Biopsies of Patients with Pulmonary Hypertension due to Congenital Heart Disease
- Increased Serum Neopterin Concentrations in Patients with Alzheimer’s Disease
- Biomarkers of Bone Turnover and Bone Mineral Density in Hyperprolactinemic Amenorrheic Women
- Age Relationships and Sex Differences in Serum Levels of Pregnenolone and 17-Hydroxypregnenolone in Normal Subjects
- A Study of Hypermagnesaemia in a Hospital Population
- Multiple Regression Analysis of Interference Effects from a Hemoglobin-Based Oxygen Carrier Solution
- Serum Ionized Magnesium: Comparison of Results Obtained with Three Ion-Selective Analyzers
- Automated Prozone Effect Detection in Ferritin Homogeneous Immunoassays Using Neural Network Classifiers
- Recent Activities of EC4 in the Harmonization of Clinical Chemistry in the European Union
- Preventing Coronary Artery Disease. Cardioprotective Therapeutics in Practice. Edited by M. J. Kendall and R. C. Horton
- Will Medical Schools Remain what They Are? Medical Education in the Millennium. Edited by Brian Jolly and Lesley Rees
Articles in the same Issue
- Serum Amyloid A (SAA): a Concise Review of Biology, Assay Methods and Clinical Usefulness
- Serum Cystatin C as an Endogenous Marker of the Renal Function – a Review
- Improved Fluorescent PCR-Based Assay for Sizing CGG Repeats at the FRAXA Locus
- The Influence of Radiation and Chemotherapy-Related DNA Strand Breaks on Carcinogenesis: An Evaluation
- A Simple HPLC Method for Monitoring Mycophenolic Acid and Its Glucuronidated Metabolite in Transplant Recipients
- The Activities of Some Glycosaminoglycan-Degrading Enzymes in the Wall of the Umbilical Cord Artery and Their Alteration in Edema, Proteinuria, Hypertension (EPH)-Gestosis
- Endothelin-1- and Endothelin-Receptors in Lung Biopsies of Patients with Pulmonary Hypertension due to Congenital Heart Disease
- Increased Serum Neopterin Concentrations in Patients with Alzheimer’s Disease
- Biomarkers of Bone Turnover and Bone Mineral Density in Hyperprolactinemic Amenorrheic Women
- Age Relationships and Sex Differences in Serum Levels of Pregnenolone and 17-Hydroxypregnenolone in Normal Subjects
- A Study of Hypermagnesaemia in a Hospital Population
- Multiple Regression Analysis of Interference Effects from a Hemoglobin-Based Oxygen Carrier Solution
- Serum Ionized Magnesium: Comparison of Results Obtained with Three Ion-Selective Analyzers
- Automated Prozone Effect Detection in Ferritin Homogeneous Immunoassays Using Neural Network Classifiers
- Recent Activities of EC4 in the Harmonization of Clinical Chemistry in the European Union
- Preventing Coronary Artery Disease. Cardioprotective Therapeutics in Practice. Edited by M. J. Kendall and R. C. Horton
- Will Medical Schools Remain what They Are? Medical Education in the Millennium. Edited by Brian Jolly and Lesley Rees