Titanium serum levels may remain elevated despite hip revision surgery for wear-through of an acetabular component Erhöhter Titan-Serumspiegel trotz Revisionsoperation bei abriebpartikelinduzierter Pfannenlockerung
-
Henning Quitmann
Abstract
A 62-year-old female patient showed radiographic signs of severe linear wear of the acetabular component six years after cementless total hip arthroplasty. This suggested wear-through of the acetabular liner with secondary wear of the titanium shell. At revision surgery wear-through of both the inlay and the acetabular shell were confirmed. Despite meticulous debridement serum titanium levels remained elevated for more than 12 months. Wear-through of a polyethylene acetabular liner with secondary wear of the titanium shell can lead to increased titanium serum levels. Titanium serum levels can remain highly elevated despite revision surgery.
Zusammenfassung
Eine 62-jährige Patientin zeigte radiologische Hinweise auf Abrieb der acetabulären Komponente einer zementfreien Hüft-Totalendoprothese sechs Jahre nach Erstimplantation. Der Abrieb setzte sich aus dem Polyethylenabrieb des Liners und dem Titanabrieb der Pfanne zusammen. Trotz sorgfältigem Debridement des periartikulären Gewebes blieb der Titanserumspiegel für mehr als 12 Monate erhöht. Acetabulärer Polyethylenabrieb und Titanabrieb können zu einem erhöhten Titanserumspiegel führen. Der Titanserumspiegel kann trotz einer Revisionsoperation hoch bleiben.
References
1 Collier JP, Mayor MB, Jensen RE, Surprenant VA, Surprenant HP, McNamar JL, et al. Mechanisms of failure of modular prostheses. Clin Orthop1992; 285: 129–139.10.1097/00003086-199212000-00017Suche in Google Scholar
2 Graeter JH, Nevins R. Early osteolysis with Hylamer acetabular liners. J Arthroplasty1998; 13: 464–466.10.1016/S0883-5403(98)90016-XSuche in Google Scholar
3 Jacobs JJ, Skipor AK, Patterson LM, Hallab NJ, Paprosky WG, Black J, et al. Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J Bone Joint Surg Am1998; 80: 1447–1458.10.2106/00004623-199810000-00006Suche in Google Scholar
4 Jacobs JJ, Silverton C, Hallab NJ, Skipor AK, Patterson L, Black J, et al. Metal release and excretion from cementless titanium alloy total knee replacements. Clin Orthop1999; 358: 173–180.10.1097/00003086-199901000-00021Suche in Google Scholar
5 Leopold SS, Berger RA, Patterson L, Skipor AK, Urban RM, Jacobs JJ. Serum titanium level for diagnosis of a failed, metal-backed patellar component. J Arthroplasty2000; 15: 938–943.10.1054/arth.2000.6632Suche in Google Scholar
6 Takai S, Yoshino N, Kusaka Y, Watanabe Y, Hirasawa Y. Dissemination of metals from failed patellar component made of titanium-base alloy. J Arthroplasty2003; 18: 931–935.10.1016/S0883-5403(03)00277-8Suche in Google Scholar
7 von Schroeder HP, Smith DC, Gross AE, Pilliar RM, Kandel RA, Chernecky R, et al. Titanemia from total knee arthroplasty. A case resulting from a failed patellar component. J Arthroplasty1996; 11: 620–625.10.1016/S0883-5403(96)80120-3Suche in Google Scholar
©2006 by Walter de Gruyter Berlin New York
Artikel in diesem Heft
- Biomedizinische Technik/Biomedical Engineering continued at Walter de Gruyter Publishers
- Methodik zur zerstörungsfreien Testung von Oberflächenbeschichtungen in der Endoprothetik Method of non-destructive mechanical testing of new surface coatings for prostheses
- Biomechanische Eigenschaften von Gelenkknorpel nach hydrostatischer Hochdruckbehandlung Biomechanical properties of articular cartilage after high hydrostatic pressure treatment
- Atomemissionsspektralanalyse mit induktiv gekoppeltem Plasma (ICP-OES) von Granulomen zementierter und zementfreier Hüftendoprothesen Examination of granuloma of revised cemented or cementless total hip arthroplasties using inductively coupled plasma atomic emission spectrometry (ICP-OES)
- Der acetabuläre Pressfit bei äquatorialer Beschichtung der zementfreien Hüftpfanne – eine finite-Elemente-Analyse Pressfit of equatorially roughened cementless acetabular components – a finite elements analysis
- Titanium serum levels may remain elevated despite hip revision surgery for wear-through of an acetabular component Erhöhter Titan-Serumspiegel trotz Revisionsoperation bei abriebpartikelinduzierter Pfannenlockerung
- V.A.C.™ instillation: in vitro model. Part 2 V.A.C.™ Instillation: ein in vitro Modell. Teil 2
Artikel in diesem Heft
- Biomedizinische Technik/Biomedical Engineering continued at Walter de Gruyter Publishers
- Methodik zur zerstörungsfreien Testung von Oberflächenbeschichtungen in der Endoprothetik Method of non-destructive mechanical testing of new surface coatings for prostheses
- Biomechanische Eigenschaften von Gelenkknorpel nach hydrostatischer Hochdruckbehandlung Biomechanical properties of articular cartilage after high hydrostatic pressure treatment
- Atomemissionsspektralanalyse mit induktiv gekoppeltem Plasma (ICP-OES) von Granulomen zementierter und zementfreier Hüftendoprothesen Examination of granuloma of revised cemented or cementless total hip arthroplasties using inductively coupled plasma atomic emission spectrometry (ICP-OES)
- Der acetabuläre Pressfit bei äquatorialer Beschichtung der zementfreien Hüftpfanne – eine finite-Elemente-Analyse Pressfit of equatorially roughened cementless acetabular components – a finite elements analysis
- Titanium serum levels may remain elevated despite hip revision surgery for wear-through of an acetabular component Erhöhter Titan-Serumspiegel trotz Revisionsoperation bei abriebpartikelinduzierter Pfannenlockerung
- V.A.C.™ instillation: in vitro model. Part 2 V.A.C.™ Instillation: ein in vitro Modell. Teil 2