Reaktor Serba Guna-G.A. Siwabessy (RSG-GAS reactor) is a pool type research reactor, located in Serpong village, Indonesia. For safety of RSG-GAS reactor, the maintenance level criterion of System, Structure and Component (SSC) can be carried out by assessing on occurrence likelihood of a potential risks due to ageing degradation and a Risk Priority Number (RPN) value for assigning maintenance criterion, respectively. The objective of present study is to propose using the Failure Mode and Effects Analysis (FMEA) for assigning the maintenance level criterion of SSC and implementing on JE01-AP01 primary pump within a RSG-GAS reactor. In this research paper, SSC screening and failure based maintenance methodology is identified and classified into suitable classes at radar diagram. Results show that SSC can be prioritized based on failure analysis so that maintenance level criterion for SSC can be determined. On the implemented study, preventive maintenance can be performed to JE01-AP01 primary pump because of its RPN value 270.