Miklos Acs, Maximilian Babucke, Maximilian Jusufi, Zsolt Kaposztas, Przemyslaw Slowik, Matthias Hornung, Hans J. Schlitt, Ivan Panczel, Judit Hevesi, Jonas Herzberg, Tim Strate, Pompiliu Piso
Treatment of peritoneal surface malignancies makes physicians face demanding and new-fangled problems, as there are many uncertain aspects considering the outcomes of affected patients’ prognoses. Cytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC) are associated with favorable long-term outcomes in carefully selected patients with peritoneal metastases (PM). We aim to summarize the current results about the initial malignancies and their peritoneal spreads. The current literature has been scrutinized, and studies between 2016 and 2022 were included wherein long-term, progression-free (PFS), and overall survival (OS) data were considered relevant information. Medline, Embase, and Google Scholar have been the main sources. Hereby, we cover all the primer malignancies: gastric, ovarian, and colorectal cancers with peritoneal metastases (PM), malignant peritoneal mesothelioma, and pseudomyxoma peritonei. Examining the advances in the current peer-reviewed literature about the indications of cytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC), target groups, risk factors, and other influencing elements, we intend to provide a complex state-of-the-art report, establishing the relevant aspects of that emerging treatment method.
Computer technology–based treatment approaches like intraoperative navigation and intensity-modulated radiation therapy have become important components of state of the art head and neck cancer treatment. Multidirectional exchange of virtual three-dimensional patient data via an interdisciplinary platform allows all medical specialists involved in the patients treatment to take full advantage of these technologies. This review article gives an overview of current technologies and future directions regarding treatment approaches that are based on a virtual, three-dimensional patient specific dataset: storage and exchange of spatial information acquired via intraoperative navigation allow for a highly precise frozen section procedure. In the postoperative setting, virtual reconstruction of the tumor resection surface provides the basis for improved radiation therapy planning and virtual reconstruction of the tumor with integration of molecular findings creates a valuable tool for postoperative treatment and follow-up. These refinements of established treatment components and novel approaches have the potential to make a major contribution to improving the outcome in head and neck cancer patients.
Objectives Intraoperative monitoring of blood flow (BF) remains vital to guiding surgical decisions. Here, we report the use of SurgeON™ Blood Flow Monitor (BFM), a prototype system that attaches to surgical microscopes and implements laser speckle contrast imaging (LSCI) to noninvasively obtain and present vascular BF information in real-time within the microscope’s eyepiece. Methods The ability of SurgeON BFM to monitor BF status during reversible vascular occlusion procedures was investigated in two large animal models: occlusion of saphenous veins in six NZW rabbit hindlimbs and clipping of middle cerebral artery (MCA) branches in four Dorset sheep brain hemispheres. SurgeON BFM acquired, presented, and stored LSCI-based blood flow velocity index (BFVi) data and performed indocyanine green video angiography (ICG-VA) for corroboration. Results Stored BFVi data were analyzed for each phase: pre-occlusion (baseline), with the vessel occluded (occlusion), and after reversal of occlusion (re-perfusion). In saphenous veins, BFVi relative to baseline reduced to 5.2±3.7 % during occlusion and returned to 102.9±14.9 % during re-perfusion. Unlike ICG-VA, SurgeON BFM was able to monitor reduced BFVi and characterize re-perfusion robustly during five serial occlusion procedures conducted 2–5 min apart on the same vessel. Across four sheep MCA vessels, BFVi reduced to 18.6±7.7 % and returned to 120.1±27.8 % of baseline during occlusion and re-perfusion phases, respectively. Conclusions SurgeON BFM can noninvasively monitor vascular occlusion status and provide intuitive visualization of BF information in real-time to an operating surgeon. This technology may find application in vascular, plastic, and neurovascular surgery.
Objectives Cholecystectomy with or without intraoperative cholangiogram (IOC) is an accepted treatment for cholelithiasis. Up to 11.6 % of cholecystectomies have incidental common bile duct (CBD) stones on IOC and 25.3 % of undiagnosed CBD stones will develop life-threatening complications. These will require additional intervention after primary cholecystectomy, further straining the healthcare system. We seek to examine the role of IOC in patients with normal LFTs by evaluating its predictive values, intending to treat undiagnosed CBD stones and therefore ameliorate these issues. Methods All patients who underwent cholecystectomies with normal LFTs from October 2019 to December 2020 were prospectively enrolled. IOC was done, ERCPs were performed for filling defects and documented as “true positive” if ERCP was congruent with the IOC. “False positives” were recorded if ERCP was negative. “True negative” was assigned to normal IOC and LFT after 2 weeks of follow-up. Those with abnormal LFTs were subjected to ERCP and documented as “false negative”. Sensitivity, specificity, and predictive values were calculated. Results A total of 180 patients were analysed. IOC showed a specificity of 85.5 % and a NPV of 88.1 % with an AUC of 73.7 %. The positive predictive value and sensitivity were 56.5 and 61.9 % respectively. Conclusions Routine IOC is a specific diagnostic tool with good negative predictive value. It is useful to exclude the presence of CBD stones when LFT is normal. It does not significantly prolong the length of hospitalization or duration of the cholecystectomy hence reducing the incidence of undetected retained stones and preventing its complications effectively.
Objectives Various techniques of closure of surgical incisions have been described ranging from various suture materials, staples and tapes to adhesive compounds. Cyanoacrylate is an adhesive compound available for surgical incision closure. Although sutures have been the preferred universal choice for surgical incision closure, glue is gaining popularity in specific places like pediatric injuries, facial injuries, laparoscopic incision closure, etc. This study aimed to compare the results between the application of cyanoacrylate and conventional suturing. Methods In this randomized control study, patients were divided into two groups of 100 each. The surgical incisions were closed using cyanoacrylate glue in Group A patients and polyamide (EthilonTM 2-0) in Group B patients. Post-operative pain was assessed using Visual Analogue Scale on the first, third, and seventh day. The wounds were evaluated for complications on post-op days 1, 3, 7, and 30 using the ASEPSIS score. Cosmetic outcome was assessed at the end of first month using the Modified Hollander Cosmesis Scale. Results Post-operative pain was significantly less in the glue group on days 1, 3, and 7. Wound infection with dehiscence occurred in 4 cases (4 %) in Group A and one patient (1 %) in Group B, which was statistically insignificant. There was no significant difference in cosmetic outcomes in either Group. Conclusions Cyanoacrylate is a good alternative to sutures in skin closure of clean and clean-contaminated surgical wounds.
Objectives Since its introduction as a clinical technique, robotic surgery has been extended to different fields of surgery. However, the indications as well as the number of robotic procedures varied in different institutions. The aim of this investigation was to evaluate the current use of robotic surgery in general and digestive surgery in Switzerland. Methods All Swiss surgical departments that are recognized training institutes for postgraduate training in surgery by the Swiss Institute of Medical Education (SIWF) were queried with a detailed questionnaire regarding the use of robotic surgery techniques and were analyzed regarding hospital size and type of hospital. Results Ninety-three departments were queried, and 67 % (n=63) answered the survey. Fifty-eight were public, and five were private institutions. Seventeen (26 %) of the queried departments used robotic surgery in digestive surgery. Four out of 17 (23 %) of the departments that performed robotic surgery were private hospitals, while 13 (77 %) were public institutions. In the majority of departments, robotic surgery of the rectum (n=12; 70.6 %) and colon (n=11; 64.7 %) was performed, followed by hernia procedures (n=8; 47.1 %) and fundoplication (n=7; 41.2 %). Less frequently, pancreatic resections (n=5; 29.4 %), cholecystectomy (n=4; 23.5 %), adrenalectomy (n=4; 23.5 %), gastric bypass (n=3; 17.7 %), gastric sleeve (n=3; 17.7 %), hepatic procedures (n=2; 11.7 %), or small bowel resections (n=1; 5.9 %) were performed as robotic procedures. More than 25 procedures per year per department were performed for hernia surgery (n=5 departments), gastric bypass (n=2 departments), cholecystectomy, fundoplication, and colon surgery (each n=1 department). Conclusions The number and range of robotic procedures performed in Switzerland varied widely. Higher accreditation for general surgery or subspecialization of visceral surgery of the department was positively associated with the use of robotic techniques, reflecting an unequal availability of robotic surgery.
Objectives Horner syndrome (HS) is a rare complication of thyroid surgery. However, the relationship between the occurrence of HS and thyroid upper pole injury is still not completely clear, and there are only few reports. Case presentation A 24-year-old female underwent endoscopic thyroidectomy for thyroid papillary carcinoma. The intraoperative examination found that the upper pole of the thyroid was bleeding. During hemostasis, the ultrasonic knife consciously peeled too deep and stopped. The patient developed HS immediately after operation. We analyzed the association between deep dissection of the upper thyroid pole and an increase in the HS incidence rate through literature searches and anatomical relationships. Conclusions Our case report discussed the potential relationship between the degree of thyroid upper pole dissection and the occurrence of HS in routine thyroid surgery, and provided a warning for the degree of thyroid upper pole dissection in the clinic to avoid HS.