A comparison study for mass attenuation coefficients of some amino acids using MCNP code
-
, and
Abstract
In this study, a novel model of MCNP4C code reported recently was used to determine the photon mass attenuation coefficients of some amino acids at energies, 123, 360, 511, 662, 1170, 1280 and 1330 keV. The simulation results were compared with the XCOM data. It was indicated that the results were highly close to the calculated XCOM values. Obtained results were used to calculate the molar extinction coefficient. All the results showed the convenience and usefulness of the model in calculation of mass attenuation coefficients of amino acids.
Kurzfassung
In dieser Studie wurde ein neuartiges Modell des MCNP4C-Codes verwendet um die Photon-Massendämpfungskoeffizienten von einigen Aminosäuren bei den Energien 123, 360, 511, 662, 1170, 1280 und 1330 keV zu bestimmen. Die Simulationsergebnisse wurden mit den XCOM-Daten verglichen. Es zeigte, dass die Ergebnisse sehr nahe an den berechneten XCOM-Werten liegen. Die erhaltenen Ergebnisse wurden verwendet, um den molaren Extinktionskoeffizienten zu berechnen. Alle Ergebnisse zeigen die Zweckmäßigkeit und die Nützlichkeit des Modells bei der Berechnung der Massendämpfungskoeffizienten von Aminosäuren.
References
1 Cember, H.: Introduction to health physics. McGraw-Hill, New York (2000)Search in Google Scholar
2 More, C. V.; Lokhande, R. M.; Pawar, P. P.: Effective atomic number and electron density of amino acids within the energy range of 0.122–1.330 MeV. Radiation Physics and Chemistry125 (2016) 14–2010.1016/j.radphyschem.2016.02.024Search in Google Scholar
3 Manohara, S. R.; Hanagodimath, S. M.: Studies on effective atomic numbers and electron densities of essential amino acids in the energy range 1 keV–100 GeV. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms258 (2007) 321–32810.1016/j.nimb.2007.02.101Search in Google Scholar
4 More, C. V.; Lokhande, R. M.; Pawar, P. P.: Effective atomic number and electron density of amino acids within the energy range of 0.122–1.330 MeV. Radiation Physics and Chemistry125 (2016) 14–2010.1016/j.radphyschem.2016.02.024Search in Google Scholar
5 Nair, K. G.; Gowda, C.; Kumari, J. S.; Anasuya, S. J.; Umesh, T. K.; Gowda, R.: Photon interaction cross sections for some amino acids in the range 30–385 keV. Radiation Physics and Chemistry43 (1994) 581–58410.1016/0969-806X(94)90171-6Search in Google Scholar
6 Gowda, S.; Krishnaveni, S.; Gowda, R.: Studies on effective atomic numbers and electron densities in amino acids and sugars in the energy range 30–1333 keV. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms239 (2005) 361–36910.1016/j.nimb.2005.05.048Search in Google Scholar
7 Vahabi, S. M.; Bahreinipour, M.; Zafarghandi, M. S.: Determining the mass attenuation coefficients for some polymers using MCNP code: A comparison study. Vacuum136 (2016) 73–7610.1016/j.vacuum.2016.11.011Search in Google Scholar
8 http://physics.nist.gov/PhysRefData/Xcom/Text/XCOM.htmlSearch in Google Scholar
9 Berger, M. J.; Hubbel, J. H.: XCOM: Photon cross section on a personal computer. Ver 1 (1987) 910.2172/6016002Search in Google Scholar
10 Shultis, J. K.; Faw, R. E.: An MCNP primer. Kansas State University, Manhattan, (2011)Search in Google Scholar
© 2017, Carl Hanser Verlag, München
Articles in the same Issue
- Contents/Inhalt
- Contents
- Summaries/Kurzfassungen
- Summaries
- Technical Contributions/Fachbeiträge
- SIMULATE-3 K coupled code applications
- Application of the new IAPWS Guideline on the fast and accurate calculation of steam and water properties with the Spline-Based Table Look-Up Method (SBTL) in RELAP-7
- Simulation of water hammer phenomena using the system code ATHLET
- New version of the reactor dynamics code DYN3D for Sodium cooled Fast Reactor analyses
- Sensitivity analysis for thermo-hydraulics model of a Westinghouse type PWR: verification of the simulation results
- Calculation of the fuel temperature coefficient of reactivity considering non-uniform radial temperature distribution in the fuel rod
- The effect of boron dilution transient on the VVER-1000 reactor core using MCNP and COBRA-EN codes
- Modelling of the spent fuel heat-up in the spent fuel pools using one-dimensional system codes and CFD codes
- Optimization and analysis of the effects of physical parameters in a TRIGA-ADSR
- A comparison study for mass attenuation coefficients of some amino acids using MCNP code
- Validation of radioactive isotope activity measurement in homogeneous waste drum using Monte Carlo codes
- Study of the response reduction of LiF:Mg, Ti dosimeter for high dose dosimetry
- Non-contact micro mass evaluation method using an X-ray microscope
Articles in the same Issue
- Contents/Inhalt
- Contents
- Summaries/Kurzfassungen
- Summaries
- Technical Contributions/Fachbeiträge
- SIMULATE-3 K coupled code applications
- Application of the new IAPWS Guideline on the fast and accurate calculation of steam and water properties with the Spline-Based Table Look-Up Method (SBTL) in RELAP-7
- Simulation of water hammer phenomena using the system code ATHLET
- New version of the reactor dynamics code DYN3D for Sodium cooled Fast Reactor analyses
- Sensitivity analysis for thermo-hydraulics model of a Westinghouse type PWR: verification of the simulation results
- Calculation of the fuel temperature coefficient of reactivity considering non-uniform radial temperature distribution in the fuel rod
- The effect of boron dilution transient on the VVER-1000 reactor core using MCNP and COBRA-EN codes
- Modelling of the spent fuel heat-up in the spent fuel pools using one-dimensional system codes and CFD codes
- Optimization and analysis of the effects of physical parameters in a TRIGA-ADSR
- A comparison study for mass attenuation coefficients of some amino acids using MCNP code
- Validation of radioactive isotope activity measurement in homogeneous waste drum using Monte Carlo codes
- Study of the response reduction of LiF:Mg, Ti dosimeter for high dose dosimetry
- Non-contact micro mass evaluation method using an X-ray microscope